COMPANY RECORD · CHICAGO, IL

Candor Electric, Inc. — permit history in Chicago, IL

Candor Electric, Inc. appears on 522 Chicago permit records from 2006 through 2026, most often electrical (99.8% of the record).

Permit categories

CategoryPermitsShare
Electrical52299.8%
General construction10.19%

2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.

Activity by year

YearPermits issued
200615
200711
200811
200939
201016
201113
201231
201321
201431
201510
201612
201735
201822
201946
202026
202156
202249
202330
20248
202527
202614

Busiest year on record: 2021, with 56 permits. One project can account for several filings, so read this as filing activity rather than workload.

Named on the same permit

Name in sourceLinked permitsLast seen
F.H. Paschen, S.N. Nielsen & Associates, LLC.452024-07-19
K.R. Miller Contractors, Inc.362026-04-27
Ccc Holdings, Inc. D/B/A Ccc Design Build232023-05-05
Sandsmith Construction Inc.212025-04-15
Agae Contractors, Inc.172023-02-24
The Bowa Group Inc152023-04-10
Blinderman Construction Co., Inc.152025-07-08
Ihc Construction Companies, L.L.C.132014-02-27
Leopardo Construction Inc112021-08-03
Friedler Construction Company102026-07-21
Mbb Enterprises Of Chicago, In92020-04-06
Auburn Corporation92018-06-19

95 companies are named alongside Candor Electric, Inc. on the same Chicago permit. A shared permit is a documented co-appearance, not proof of a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
707 W JUNIOR TER2026-07-23
5515 S LOWE AVE2026-07-21
5015 S BLACKSTONE AVE2026-07-15
1734 N ORLEANS ST2026-06-15
5300 S HERMITAGE AVE2026-04-27
700 N MICHIGAN AVE2026-04-02
6710 N WASHTENAW AVE2026-03-25
4624 W MADISON ST2026-02-27
60 W KINZIE ST2026-01-05
1371 W RANDOLPH ST2025-12-01
5838 N LINCOLN AVE2025-11-20
1852 W 19TH ST2025-08-27
3601 N MILWAUKEE AVE2025-08-22
2815 S KOMENSKY AVE2025-08-22

365 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $1 to $23,230,800, median $154,777. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

522 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
1010820512026-07-23Electrical707 W JUNIOR TERSELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO AN EXISTING RESIDENTIAL CONDO BUILDING REQUIRED FOR THE ELEVATOR MODERNIZATION INCLUDING CREATING A 2-HOUR RATED ELEVATOR MACHINE ROOM$1,069,521
1010809752026-07-21Electrical5515 S LOWE AVESELF-CERT 2019 CBRC: ROOFING REPLACEMENT WITH SELECT MEP INTERVENTION REQUIREMENTS, REMOVE AND REPLACE 2 EXISTING EXTERIOR EXIT STAIRS. STRUCTURAL PEER REVIEW REPORT.$5,300,000
B2004672072026-07-15Electrical5015 S BLACKSTONE AVEFIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101043168. AFFECTS: 0 DWELLING UNITS; 0 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION:
B2004725402026-06-15Electrical1734 N ORLEANS STFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
B2004654112026-05-18Electrical5015 S BLACKSTONE AVEFIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101043168. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION:
1010790622026-05-14Electrical1734 N ORLEANS STSELF-CERT 2019 CBRC: REPLACEMENT OF HVAC SYSTEM AND STEAM BOILERS, PATCHING OF WALLS, FLOORS, CEILING AFFECTED BY MEP WORK$4,654,000
1010801182026-04-27Electrical5300 S HERMITAGE AVESELF-CERT 2019 CBRC: CHICAGO PUBLIC SCHOOL FACILITY. NO CHANGE IN USE. LOCALIZED TOILET ROOM REPAIRS AND MODIFICATIONS. INTERIOR LIFT INSTALLATION. LOCALIZED EXTERIOR PAVING REPAIR$807,370
1010811662026-04-02Electrical700 N MICHIGAN AVEINTERNALLY BACK LIT BUSINESS ID SIGN TO STATE "ZARA" FACING SOUTH, BEHIND THE GLASS. 20' ABOVE GRADE$5,000
1010811652026-04-02Electrical700 N MICHIGAN AVEINTERNALLY BACK LIT BUSINESS ID SIGN TO STATE "ZARA" FACING EAST, BEHIND THE GLASS. 20' ABOVE GRADE$5,000
1010796142026-03-31Electrical700 N MICHIGAN AVEINTERNALLY BACK LIT BUSINESS ID SIGN TO STATE "ZARA" ABOVE STOREFRONT DOORS$5,000
1010796152026-03-31Electrical700 N MICHIGAN AVEINTERNALLY BACK LIT BUSINESS ID SIGN TO STATE "ZARA" FACING SOUTHEAST, ALONG CURVED FACADE 20' ABOVE GRADE$5,000
1010794182026-03-25Electrical6710 N WASHTENAW AVESC 2019 CBRC: ROOF REPLACEMENT, MASONRY REPAIRS, SELECT INTERIOR SCOPE INCLUDING FINISHES, ELECTRICAL, AND MECHANICAL$4,000,000
B2004586222026-02-27Electrical4624 W MADISON STFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: SUPER
B2004532462026-01-05Electrical60 W KINZIE STLINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. ELECTRIC VEHICLE SUPPLY EQUIPMENT:24 SPACES. SPECIFIC LOCAT$20,000
B2004529372025-12-15Electrical4624 W MADISON STFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
1010767542025-12-01Electrical1371 W RANDOLPH STCBC-2019 SELF CERT - INTERIOR BUILD OUT FOR A NEW PHYSICAL THERAPY OFFICE WITHIN AN EXISTING TENANT SPACE. WORK SHALL INCLUDE ARCHITECTURALWALLS AND FINISHES, MECHANICAL, PLUMBING,$450,000
B2004517322025-11-20Electrical5838 N LINCOLN AVELOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL AUDIO. INSTALL DATA/VIDEO. SPECIFIC LOCATION: 1ST FLOOR.$20,000
B2004324962025-10-23Electrical4624 W MADISON STFIRE ALARM: NEW SYSTEM. ASSOCIATED BUILDING PERMIT:101046045. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING:
1010690372025-08-27Electrical1852 W 19TH STSC 2019 CBRC: INTERIOR RENOVATION TO CONVERT AN EXISTING STORAGE SPACE INTO DRESSING ROOMS AND RESTROOM.$50,000
B2004339872025-08-22Electrical3601 N MILWAUKEE AVELINE VOLTAGE ELECTRICAL WORK. ADD 2 CIRCUITS TO EXISTING 20 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 2 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: 2ND FLOOR.$10,000
B2004337532025-08-22Electrical2815 S KOMENSKY AVEFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
B2004328882025-08-01Electrical1414 E 61ST PLFIRE ALARM: NEW SYSTEM. ASSOCIATED BUILDING PERMIT:101063520. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING:
1010698992025-07-08Electrical2148 N LONG AVECPS SCHOOL - NO CHANGE IN USE. SELF-CERT 2019 CBRC: ALTERATION TO ADD A STORAGE CLOSET IN BASEMENT OF EXISTING SCHOOL BUILDING AND REPLACEMENT OF ASSOCIATED MECHANICALS FOR THIS L$668,000
1010710222025-07-03Electrical4438 W WRIGHTWOOD AVESELF-CERT 2019 CBRC: INTERIOR ALTERATION TO BASEMENT BOILER ROOM TO ADD GRINDER PUMP, REROUTE MINIMAL PLUMBING LINES ASSOCIATED WITH PUMP, ADD ELECTRIC HEATER AND MINIMAL ASSOCIATE$192,000
1010508522025-06-24Electrical127 E SOUTH WATER LOWER STSPR 2019 CBC, NO CHANGE TO USE OR OCCUPANCY: PROPOSD METRA STATION RENOVATION OF WAITING ROOM, STAFF LOCKER ROOM, AND SUPPORT SPACES FOR IMPROVED PASSENGER EXPERIENCE AND CIRCULATI$5,882,267
B2004269162025-06-09Electrical4728 N WOLCOTT AVEFIRE ALARM: NEW SYSTEM. ASSOCIATED BUILDING PERMIT:B200421909. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING:
1010644932025-06-05Electrical8530 S WOOD STSPR 2019 CBRC: EXTERIOR IMPROVEMENTS AT CPS FOSTER PARK TO INCLUDE PAVEMENT REPLACEMENT AND RECONFIGURATION OF THE PARKING LOT, PLAYGROUND REPLACEMENT, DRIVEWAY RELOCATION, PROPOSE$2,067,000
1010665922025-06-03Electrical3825 S WASHTENAW AVESC 2019 CBC: ROOF REPLACEMENT AT ALL EXISTING ROOFS AND MECHANICAL UPGRADES TO THE BUILDING AT AN EXISTING CPS ELEMENTARY SCHOOL. ADD MECHANICAL VENTILATION AND EXHAUST TO THE MAIN$3,800,000
1010638092025-05-20Electrical4959 S ARCHER AVESELF-CERT 2019 CBRC: ALTERATIONS TO EXISTING ELEVATOR LOBBY AREAS ON LOWER LEVEL THRU ROOF LEVEL AND MECHANICAL AND ELECTRICAL WORK IN EXISTING ELEVATOR MACHINE ROOM (USE GROUP E1 $700,000
B2004246592025-05-14Electrical1423 W BRYN MAWR AVELOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: SCHOOL.$100,000
B2004228762025-05-14Electrical6024 W WARWICK AVEFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
B2004232212025-05-14Electrical1241 W 19TH STFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
B2004232362025-05-14Electrical2001 S THROOP STFIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: CITY
1010648832025-05-09Electrical7342 S HOYNE AVESPR 2019 CBRC - ALTERATIONS AT GROUND FLOOR INTERIOR OF EXISTING 2 STORY BUILDING FOR NEW GARDEN, PLUMBING & ELECTRICAL CONNECTIONS (INCLUDES 1 STORY WOOD TYPE VB STORAGE SHED, 1 $2,064,000
1010675942025-05-07Electrical2815 S KOMENSKY AVEELF-CERT 2019 CBRC: CONSTRUCT NEW INTERIOR ELEVATOR SHAFT, INTERIOR ALTERATIONS TO EXISTING CLASSROOMS CONFERENCE ROOM STORAGE ROOMS AND OFFICE SPACES ON LOWER LEVEL, 1ST, 2ND, AND$3,000,000
B2004219092025-04-23Electrical4728 N WOLCOTT AVELOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: SCHOOL.$500,000
1010652912025-04-17Electrical5024 S WOLCOTT AVESELF CERT PROJECT - CPS SCHOOL - NO CHANGE IN USE - RENOVATION OF ROOF MATERIAL AND ROOF MOUNTED MEP COMPONENTS.$2,346,000
1010635202025-04-15Electrical1414 E 61ST PLSELF CERT - CHICAGO PUBLIC SCHOOL CARNEGIE ELEMENTARY - RENOVATION PROJECT FOR MECHANICAL EQUIPMENT REPLACEMENT, REPLACEMENT OF GENERATOR AND ARCHITECTURAL FINISHES TO ACCOMMODATE$4,500,000
B2004180522025-03-25Electrical5150 W 55TH STLINE VOLTAGE ELECTRICAL WORK. ADD 2 CIRCUITS TO EXISTING 20 AMP SERVICE DISCONNECTING MEANS. ADD 1 CIRCUITS TO EXISTING 30 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 3 . $25,000
1010643292025-02-21Electrical2651 W WASHINGTON BLVDSELF-CERT 2019 CBRC: ALTERATION TO EXISTING BUILDING. THE WORK CONSISTS OF REROOFING WITH A FLUID-APPLIED ROOFING SYSTEM OVER HEAVILY PATCHED AND REPAIRED SECTIONS OF THE ROOFS. T$3,000,000
1010460452025-02-13Electrical4624 W MADISON STSPR 2019 CBRC, PBC/CCC - #03720: SINGLE-STORY ADDITION TO EXISTING SINGLE-STORY BUILDING WITH PARTIAL LOWER LEVEL. ADDITION WILL HOUSE ASSEMBLY HALL AND SUPPORT FUNCTIONS; INTERIOR$7,410,316
1010617112024-10-31Electrical701 N KILBOURN AVE3-STORY, 52,000 SF EMS ADDITION TO THE SOUTH FO THE EXISTING JOINT PUBLIC SAFETY TRAINING CAMPUS PHASE II MAIN TRAINGING BUILDING$1
1010098182024-08-23Electrical4438 W WRIGHTWOOD AVESELF-CERT 2019 CBRC. RENOVATION OF CHICAGO PARK DISTRICT- KELVYN (WILLIAMS) PARK FIELDHOUSE. WORK INCLUDES ACCESSIBILITY UPGRADES: EXTERIOR RAMP/STAIRS, (1) CLUB ROOM AND (2) BATHR$2,000,000
1010534522024-08-16Electrical5100 N LEAVITT STSPR 2019 CBRC: IMPROVEMENTS TO THE BASEBALL FIELD AT WINNEMAC PARK TO INCLUDE ARTIFICIAL TURF FIELD, PAVEMENT, BACKSTOP, BENCHES, SAFETY NETTING, AND EXTERIOR LIGHTING. NO BUILDIN$1,535,000
1010431682024-07-19Electrical5015 S BLACKSTONE AVESPR 2024 CBRC: PBC/ CPS ADDITION TO EXISTING BUILDING. CONNECTION OF CANTER SCHOOL BUILDING AND KENWOOD ACADEMY SCHOOL WITH A BRIDGE (LINK) CONNECTION ON THE 2ND FLOOR. ADDITIONAL$4,794,816
B2000188142024-07-12Electrical2301 W 21ST PLHYDRONIC PIPING EXTENSION/RECONFIGURATION, REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS : 1 CHILLER(CARRIER, 30RC- 15255356, ROOF) . ELECTRICAL WORK UNDER THIS PERMIT = YES . LOCATIONS$737,000
B1010541252024-06-26Electrical938 W NORTH AVELIGHTING REPLACEMENT$65,000
1010431782024-06-12Electrical5015 S BLACKSTONE AVESPR 2024 CBRC: PBC/ CPS ALTERATION TO EXISTING BUILDING. ADDING DX COOLING TO EXISTING STEAM AIR HANDLING UNITS UP IN PENTHOUSE OF KENWOOD HIGH SCHOOL. DEMOLITION AND REPLACEMENT $1,340,280
B1010412442024-01-19Electrical5835 N LINCOLN AVE**FIRE ALARM PERMIT**PROVIDING A NEW CITY OF CHICAGO CLASS I FIRE ALARM SYSTEM IN AN EXISTING 2 STORY C3 TYPE 1A SCHOOL W/BASEMENT. ELEVATOR RECALL IS PART OF THIS SCOPE AND WILL $50,000
1009955312023-11-09Electrical118 N CLARK STSPR 2019 CBRC: ALTERATION OF EXISTING 5TH FLOOR OFFICE AND ASSEMBLY SPACES TO ACCOMMODATE ADDITIONAL STAFF REQUIREMENTS AND TO PROVIDE ADA ACCESSIBILITY THROUGHOUT THE ENTIRE FLOOR$20,000,000

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Chicago permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →