COMPANY RECORD · NEW YORK, NY

Fresh Meadow Mechanical C — permit history in New York, NY

Fresh Meadow Mechanical C appears on 42 New York permit records from 2019 through 2026, most often mechanical / hvac (80% of the record).

Permit categories

CategoryPermitsShare
Mechanical / HVAC3680%
General construction920%

2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.

Activity by year

YearPermits issued
20191
20203
20215
20226
202312
20249
20255
20264

Busiest year on record: 2023, with 12 permits. One project can account for several filings, so read this as filing activity rather than workload.

Named on the same permit

Name in sourceLinked permitsLast seen
Fresh Meadow Mech Plbg Ll12023-09-13

1 companies are named alongside Fresh Meadow Mechanical C on the same New York permit. A shared permit is a documented co-appearance, not proof of a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
150 55 STREET2026-08-27
620 8 AVENUE2026-05-20
177 FT WASHINGTON AVENUE2026-03-09
530 WEST 120 STREET2025-10-21
9 METROTECH CENTER2025-10-02
355 BARD AVENUE2025-07-31
104 WEST 40 STREET2025-02-27
506 LENOX AVENUE2024-10-22
56-45 MAIN STREET2024-10-10
5645 MAIN STREET2024-09-30
4520 33 STREET2024-04-24
605 THIRD AVENUE2024-04-17
299 PARK AVENUE2024-03-07
1269 LEXINGTON AVENUE2024-01-18

33 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $1,000 to $6,000,000, median $500,000. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

42 permits; open the full list
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
B01107884-S3-MS2026-08-27Mechanical / HVAC150 55 STREETNYULHB - Install new 48 diameter, 316 stainless steel chimney liner within existing boiler stack to height 175'-0, including new breeching connections serving existing low pressure$2,000,000
B01107884-S1-MS2026-08-26Mechanical / HVAC150 55 STREETNYU - 150 55TH STREET - Mechanical work on first floor Associated with the installation of (2) New 49.5 HP, Dual fuel boilers. Boiler work and plumbing work filed under separate $260,000
M01003695-I1-MS2026-05-20Mechanical / HVAC620 8 AVENUENYT-RECONFIGURATION OF COGEN HEAT REJECTION SYSTEM INCLUSIVE OF SILENCER REPLACEMENT AND RELATED MECHANICAL PIPING MODIFICATIONS AS PER PLANS FILED.$340,000
M01314744-I1-MS2026-03-09Mechanical / HVAC177 FT WASHINGTON AVENUEMILSTEIN CWP: MODIFICATIONS TO HVAC DUCTWORK AND PIPING INCLUDING THE INSTALLATION OF 6 CONDENSER WATER PUMPS TO ACCOMMODATE THE CHILLER REPLACEMENT IN THE EXISTING MILSTEIN HOSPIT$4,000,000
M00869564-I1-MS2025-10-21Mechanical / HVAC530 WEST 120 STREETRefurbishment of the existing Heating and Ventilation (H&V) Units within the boiler plant. There are five (5) H&V Units in total. The project also includes the replacement of one ($2,268,000
B01238145-I1-MS2025-10-02Mechanical / HVAC9 METROTECH CENTERREPLACEMENT OF 4 PACKAGED UNIT WITH A TOTAL CAPACITY OF 10.5 TONS ON THE GROUND FLOOR, FLOOR 007, FLOOR 008. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.$38,500
S01259498-S1-MS2025-07-31Mechanical / HVAC355 BARD AVENUEInstallation / retrofit of two selective catalytic reduction systems associated with the existing cogeneration plant$700,000
S01259498-I1-GC-CX2025-07-24General construction355 BARD AVENUEStructural work in conjunction with the Installation / retrofit of two selective catalytic reduction systems associated with the existing cogeneration plant$300,000
M01135927-S1-MS2025-02-27Mechanical / HVAC104 WEST 40 STREETTHE REMOVAL OF (2) EXISTING 310 TON STEAM ABSORPTION CHILLERS AND THEINSTALLATION OF (2) NEW 310 TON ELECTRIC CENTRIFUGAL MACHINES., A NEW SIDESTREAM SAND FILTER ON THE CONDENSER W$200,000
M01108108-I1-MS2024-10-22Mechanical / HVAC506 LENOX AVENUEInstallation of mechanical piping for the 3 new boilers in the cellar.$4,000,000
Q00982440-I1-GC2024-10-10General construction56-45 MAIN STREETNYPQ - AC 3, 4, A 5 REPLACEMENT - GENERAL CONSTRUCTION AS PER PLANS FILED HEREWITH INCLUDING CEILING, FLOOR, WALL AND DOOR MODIFICATIONS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.$200,000
Q00962203-I1-MS2024-09-30Mechanical / HVAC5645 MAIN STREETNYPQ - AC 3, 4, 5 REPLACEMENTS - MECHANICAL MODIFICATIONS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.$1,300,000
M00942349-I1-GC2024-09-10General construction506 LENOX AVENUECONTRACTOR TO REMOVE ALL STEAM, WATER AND CONDENSATE PIPING,EQUIPMENT, DUCTWORK, AIR OUTLETS, ETC, WITHIN THE BOILER ROOM AND IS NOTACTIVE OR TO BE REUTILIZED.$1,500,000
M00942349-I1-GC2024-09-10Mechanical / HVAC506 LENOX AVENUECONTRACTOR TO REMOVE ALL STEAM, WATER AND CONDENSATE PIPING,EQUIPMENT, DUCTWORK, AIR OUTLETS, ETC, WITHIN THE BOILER ROOM AND IS NOTACTIVE OR TO BE REUTILIZED.$1,500,000
Q00939760-I1-MS2024-04-24Mechanical / HVAC4520 33 STREETModification to existing HVAC system as per plans filed herewith. No change in use, egress or occupancy under this application.$731,500
M00965490-I1-MS2024-04-17Mechanical / HVAC605 THIRD AVENUEMechanical modifications to take place on cellar floor as per drawings filed herewith. No change in use, egress, or occupancy.$300,000
M00963752-I1-MS2024-03-07Mechanical / HVAC299 PARK AVENUEMechanical modifications taking place on the first floor as per drawings filed herewith. no change in use, egress, or occupancy.$365,095
M00826792-I1-MS2024-01-18Mechanical / HVAC1269 LEXINGTON AVENUEREPLACEMENT OF 10 TON CONDENSING UNIT ON THE 6TH FLOOR. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.$35,750
M00958432-I1-GC-CX2023-12-05General construction506 LENOX AVENUEInstallation of (2) temporary emergency boilers$50,000
M00958432-I1-GC-CX2023-12-05Mechanical / HVAC506 LENOX AVENUEInstallation of (2) temporary emergency boilers$50,000
M00942349-I1-MS2023-11-27General construction506 LENOX AVENUECONTRACTOR TO REMOVE ALL STEAM, WATER AND CONDENSATE PIPING,EQUIPMENT, DUCTWORK, AIR OUTLETS, ETC, WITHIN THE BOILER ROOM AND IS NOTACTIVE OR TO BE REUTILIZED.$1,500,000
M00942349-I1-MS2023-11-27Mechanical / HVAC506 LENOX AVENUECONTRACTOR TO REMOVE ALL STEAM, WATER AND CONDENSATE PIPING,EQUIPMENT, DUCTWORK, AIR OUTLETS, ETC, WITHIN THE BOILER ROOM AND IS NOTACTIVE OR TO BE REUTILIZED.$1,500,000
M00924288-I1-GC2023-09-01General construction506 LENOX AVENUEInstallation of (2) temporary emergency boilers$50,000
M00622532-I1-MS2023-07-27Mechanical / HVAC110 ANDES ROADMODIFICATIONS TO EXISTING MECHANICAL SYSTEMS TO INCLUDE HVAC INSTALLATION AND ASSOCIATED DUCT WORK AS PER PLANS SUBMITTED HEREWITH. NO CHANGE TO USE, OCCUPANCY OR EGRESS UNDER THIS$20,000
M00825698-I1-MS2023-06-30Mechanical / HVAC777 THIRD AVENUERevised chiller removal from existing CH-1 to existing CH-2. Revised location of new electric chillers in place of existing CH-2. New tags revised to align with the existing to rem$650,000
M00825665-I1-MS2023-06-30Mechanical / HVAC437 MADISON AVENUEREPLACE CHILLER AND ASSOCIATED PIPING.$480,000
M00862093-I1-GC2023-05-17General construction1200 FDR DRIVEHerewith filing general construction modifications for NYU Langone Access Platform. No change in use, egress, or occupancy.$100,000
M00479888-I1-MS2023-03-23Mechanical / HVAC89 CONVENT AVENUEIn kind replacement of rooftop unit. Addition of cooling for server room. Addition of cooling/dehumidification in lab.$250,040
M00750590-I1-MS2023-02-27Mechanical / HVAC731 LEXINGTON AVENUEFiling herewith for HVAC ductwork as per plans filed herewith.$325,000
M08038543-I1-MS2023-02-17Mechanical / HVAC11 PENN PLAZAChiller replacement on sub-cellar 2 as indicated on drawings$6,000,000
M00793455-I1-MS2022-12-06Mechanical / HVAC1200 FDR DRIVEENERGY BUILDING - MECHANICAL MODIFICATIONS ACCORDING TO PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.$700,000
B00634029-I1-MS2022-07-13Mechanical / HVAC1 METROTECH CENTERINSTALLATION OF CHILLER UNITS WITH RELATED PIPING AS PER PLANS FILED HEREWITH.$1,750,000
B00634085-I1-MS2022-06-18Mechanical / HVAC2 METROTECH CENTERAPPLICATION FILED TO OBTAIN REQUIRED COC FOR CHILLERS INSTALLED UNDER #301826549 AS PER PLANS FILED HEREWITH.$1,000
M00622045-I1-MS2022-04-25Mechanical / HVAC3 TIMES SQUAREChilled Water Riser Repurposing$3,599,993
M00622021-I1-MS2022-02-01Mechanical / HVAC3 TIMES SQUARENew chilled water piping for existing and future AC units.$500,000
B00644735-I1-MS2022-01-20Mechanical / HVAC625 ATLANTIC AVENUEREPLACEMENT OF 4 UNITS ON THE ROOFTOP WITH A TOTAL CAPACITY OF 160 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.$292,300
M00361546-I1-MS2021-08-11Mechanical / HVAC415 COLUMBUS AVENUEPROPOSE TO UPGRADE STEAM PIPING AS SHOWN ON DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.$800,000
M00501439-I1-GC2021-06-25General construction305 WEST 28 STREETEXCAVATION AND SHORING, AND SEALING OF OPENING TO RECEIVED PIPPING AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.$20,000
M00496070-I1-MS2021-06-15Mechanical / HVAC770 BROADWAYMechanical work associated with the replacement of chiller in the sub-cellar as indicated on drawings.$883,000
M00487760-I1-GC2021-04-09General construction424 EAST 34 STREETThis application is being filed for the removal of two silencers and existing silencer supports for support of installation of a pollution control system for two emergency generat$323,000
M00482285-I1-MS2021-04-07Mechanical / HVAC424 EAST 34 STREETThis application is being filed to install a pollution control system for two existing emergency generators on the Roof of Kimmel Pavilion.$323,000
M00304134-I1-MS2020-07-22Mechanical / HVAC1675 BROADWAYREPLACEMENT OF AC UNITS AS SHOWN ON PLANS FILED HEREWITH AT 31st THRU 35TH FLOOR$585,000
M00265633-I1-MS2020-03-18Mechanical / HVAC1000 10 AVENUEMount Sinai - Surgical Platform Phase 5 - Mechanical modifications as per plans filed herewith. No change in use, egress, or occupancy.$663,117
M00272797-I1-MS2020-02-11Mechanical / HVAC641 LEXINGTON AVENUEREPLACING STEAM DRIVEN CHILLER WITH NEW ELECTRIC DRIVE CHILLER IN THE CELLAR. NO CHANGE IS USE, EGRESS, OR OCCUPANCY$600,000
M00227080-I1-MS2019-11-08Mechanical / HVAC1109 5 AVENUEInterior Renovation associated with Mechanical Scope - Chiller upgrade. No change of use, egress or occupancy.$500,000

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public New York permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →