COMPANY RECORD · MINNEAPOLIS, MN

Corval Constructors Inc — permit history in Minneapolis, MN

Corval Constructors Inc appears on 88 Minneapolis permit records from 2017 through 2026, most often mechanical / hvac (63.6% of the record).

Permit categories

CategoryPermitsShare
Mechanical / HVAC5663.6%
Plumbing3236.4%

2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.

Activity by year

YearPermits issued
201722
201813
201917
20208
20216
20223
20235
20249
20253
20262

Busiest year on record: 2017, with 22 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
1009 PARK AVE2026-04-02
1800 PARK AVE2026-02-24
2406 RIVERSIDE AVE2025-12-03
2929 1ST AVE S2025-09-18
7TH ST N and 1ST AVE N2025-04-24
620 12TH AVE S2024-09-05
2872 26TH AVE S2024-08-12
275 MARKET ST2024-07-15
700 WASHINGTON AVE N2024-06-28
30 3RD AVE SE2024-06-03
100 2ND ST NE #A5602024-01-22
1016 SIBLEY ST NE2023-09-29
100 2ND ST NE #A3102023-09-05
625 4TH AVE S2023-04-06

55 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

88 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
BLDG11705932026-04-02Mechanical / HVAC1009 PARK AVEBoiler feed tank water meter
BLDG11659182026-02-24Mechanical / HVAC1800 PARK AVERun new 1/2 gas line to three existing driers and tie into existing gas meter
BLDG11536562025-12-03Mechanical / HVAC2406 RIVERSIDE AVEReplace Gas piping
BLDG11409862025-09-18Mechanical / HVAC2929 1ST AVE SRunning gas line from tank to mixer then building
BLDG11148642025-04-24Mechanical / HVAC7TH ST N and 1ST AVE NRepair casing as needed and repair condensate line. Located between vault 89 and 90.
BLDG10820532024-09-05Plumbing620 12TH AVE SAdding 2 additional floor sinks to Plumbing Permit PLUMBING/BLDG1066804
BLDG10713012024-08-12Mechanical / HVAC2872 26TH AVE SReplace 4 RTUs Review Note: Unless technically unfeasible, new and replacement rooftop equipment shall be provided with insulated curbs as described in the 2024 Minnesota E
BLDG10668202024-08-01Mechanical / HVAC620 12TH AVE SInstalling kitchen hood, make up air unit, kitchen exhaust fan and associated grease duct.
BLDG10668432024-07-15Mechanical / HVAC275 MARKET ST60 TON RTU REPLACEMENT Review Note: Unless technically unfeasible, new and replacement rooftop equipment shall be provided with insulated curbs as described in the 2024 Mi
BLDG10668042024-06-28Plumbing620 12TH AVE SFOR LOCAL 563 - KITCHEN FIXTURES: Addition of floor drain, hand sink, and 3 comp sink for kitchen, glass drain on upper level roof. Also 6 burner range.
BLDG10681312024-06-28Plumbing700 WASHINGTON AVE NDomestic water boiler replacement - Boiler is 399,000 BTUs. Building penthouse.
BLDG10625432024-06-03Plumbing30 3RD AVE SEXCEL ENERGY - NEW LOWER LEVEL RESTROOM Fabricate stainless steel holding tank for sanitary waste and construction of restroom and associated plumbing piping in the lower level of
BLDG10531302024-04-12Mechanical / HVAC275 MARKET STremove boiler replace w/2 condensing boilers
BLDG10405762024-01-22Plumbing100 2ND ST NE #A560Moving two gas lines (one for the fireplace and the other for a range) less than 2 feet away in unit 560 in the 100 Building
BLDG10219862023-11-09Mechanical / HVAC275 MARKET STHVAC system, installing one VAV box, GRDs and all associated ductwork per approved plans.
BLDG10075932023-09-29Mechanical / HVAC1016 SIBLEY ST NERPZ should be addressed on a plumbing permit. Adv applicant. Drawing available in projectdox. Valuation changed by contractor in response to changemark. BLDG1007593
BLDG10161632023-09-05Plumbing100 2ND ST NE #A310gas line for outdoor grill
BLDG9883362023-04-06Plumbing625 4TH AVE SFOR 16TH FLOOR - INSTALL 400 FEET OF WASTE AND VENT PIPING
BLDG9843582023-03-09Mechanical / HVAC2858 26TH AVE SREPLACE 3 RTU'S
BLDG9573792022-08-18Plumbing333 TAFT ST NEMAIN LINE REPAIR - Repairing clean out in main line to street
BLDG9398222022-05-19Mechanical / HVAC88 11TH AVE NEReplacing air handling unit coil.
BLDG9414682022-05-09Mechanical / HVAC609 OAK ST SERepair of snowmelt piping.
BLDG9089902021-12-13Mechanical / HVAC414 NICOLLET MALLHVAC system, demo nine existing air handling units and replacing all equipment, demo and replace two low pressure steam boilers, boilers should meet the required efficiencies by co
BLDG9157722021-11-18Mechanical / HVAC816 4TH AVE SMake-up water piping for boiler.
BLDG9092952021-11-05Mechanical / HVAC625 4TH AVE SHVAC system, Replacing nine existing air-handling units and all associated , refurbishing four air-handling units, replacing and adding fan-coil units, adding in line air-handling
BLDG9114222021-10-07Mechanical / HVAC7TH ST S and 3RD AVE SReplacement of steam condensate piping between below sidewalk steam valults.
BLDG9092432021-09-23Plumbing625 4TH AVE S330' underground waste piping, waste and vent stacks, domestic water booster pump, (5) electric water heaters, and (24) roof drains.
BLDG9084052021-09-20Plumbing625 4TH AVE S
BLDG8488492020-11-30Plumbing500 NICOLLET MALLPlumbing for Kitchenette
BLDG8440812020-08-18Mechanical / HVAC1240 WEST RIVER PKWYProcess piping and gas piping replacement.
BLDG8407922020-07-13Plumbing1518 CHESTNUT AVE W
BLDG8269392020-05-07Mechanical / HVAC1201 BANNEKER AVE NREPLACE 1.6 MBH BOILER / GAS PIPING / HOT WATER PIPING / BUILDING #3
BLDG8269362020-05-07Mechanical / HVAC1201 12TH AVE NREPLACE 8000 MBH BOILER / GAS PIPING / HOT WATER PIPING / BUILDING #1 TOWER
BLDG8269382020-05-07Mechanical / HVAC1121 12TH AVE NREPLACE 1.6 MBH BOILER / HOT WATER PIPING / GAS PIPING / BUILDING #2
BLDG8269402020-05-07Mechanical / HVAC1221 BANNEKER AVE NREPLACE 1.6 MBH BOILER / GAS PIPING / HOT WATER PIPING / BUILDING #4
BLDG8103582020-01-17Mechanical / HVAC816 4TH AVE SChanging existing process piping
BLDG8104332019-12-26Plumbing816 4TH AVE SRPZ INSTALLATION, 4 HOSS BIBB, 500' WATER PIPING
BLDG8044802019-11-21Mechanical / HVAC1518 CHESTNUT AVE WHVAC System including adding split system for cooling of server room and all associated condensing pump and duct work and diffusers. refer to attached drawings.
BLDG7951612019-10-29Mechanical / HVAC1301 2ND AVE SHVAC system, replacing 4 fan-coil units with new one and all associated ductwork and registers. Refer to attached drawings.
BLDG7964042019-09-30Mechanical / HVAC616 10TH AVE SHIGH PRESSURE STEAM PIPING
BLDG7951662019-09-24Plumbing1301 2ND AVE SKITCHEN SINK
BLDG7920112019-09-09Mechanical / HVAC1611 6TH ST SReplacing existing main makeup air and exhaust register inside dwelling units without touching their ducts and replacing the exhaust fans at roof level. Refer to attached drawings
BLDG7867332019-08-27Mechanical / HVAC1518 CHESTNUT AVE WHVAC system upgrade, adding seven VAV boxes and all associated duct and diffusers. Adding finned tube and related piping. Refer to attached drawings.
BLDG7884592019-08-14Mechanical / HVAC1810 FRANKLIN AVE EDUST COLLECTION SYSTEM PER ENGINEERED DRAWINGS / PDF ATTACHED
BLDG7867362019-07-30Plumbing1518 CHESTNUT AVE W
BLDG7773682019-06-07Mechanical / HVAC90 11TH ST SSTEAM PIPING ONLY / NO EQUIPMENT
BLDG7763402019-06-07Mechanical / HVAC1000 MARQUETTE AVESTEAM PIPING ONLY / NO EQUIPMENT
BLDG7763022019-06-04Mechanical / HVACHENNEPIN AVE and 8TH ST S and 8TH ST NHIGH PRESS. STEAM PIPING
BLDG7706802019-05-23Mechanical / HVAC828 SPRING ST NEReplacing the all heating valves for fine tubes radiation heating. Refer to attached drawings
BLDG7651232019-04-26Mechanical / HVAC716 7TH ST SNEW AIR HANDLER / DUCTS HOT WATER PIPING / ALL NEW HIGH PRESSURE STEAM PIPING ON SEPERATE PERMIT / PLANS ATTACHED

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Minneapolis permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →