COMPANY RECORD · NEW ORLEANS, LA

Andrew Barber — permit history in New Orleans, LA

Andrew Barber appears on 40 New Orleans permit records from 2020 through 2026, all of them mechanical / hvac.

Permit categories

CategoryPermitsShare
Mechanical / HVAC40100%

Activity by year

YearPermits issued
20202
20219
20221
20237
202414
20256
20261

Busiest year on record: 2024, with 14 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
275 La Salle St2026-04-10
2950 Ben Weiner Dr2025-09-23
6450 S Claiborne Ave2025-08-27
900 Convention Center Blvd, Phase 1 Area 22025-07-23
2001 Leon C Simon Dr2025-06-30
5620 Read Blvd2025-05-01
717 Orleans Ave2024-12-19
900 Convention Center Blvd, Phase 1 Area 12024-11-26
2111 Saint Charles Ave2024-10-08
1301 Audubon St2024-04-24
1700 Perdido St2024-03-08
1430 Tulane Ave2024-03-08
1440 Canal St2024-03-08
145 Elk Pl2024-03-08

24 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $0 to $6,000,000, median $25,000. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

40 permits; open the full list
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
26-05960-FGAS2026-04-10Mechanical / HVAC275 La Salle StAdd a gas regulator and gas connection to boiler. $2,500
25-26049-HVAC2025-09-23Mechanical / HVAC2950 Ben Weiner DrInstall 1 new energy recovery ventilator on a dedicated outdoor air unit. $75,000
25-25937-HVAC2025-09-23Mechanical / HVAC275 La Salle StINTERIOR BUILDOUT OF NEW WORKSPACES, OFFICES, CLASSROOMS, ETC. WITHIN SCOPE AREA ON LEVELS 01 AND “MEZZANINE” (LEVEL 01.5) FOR TENANT (COLLEGE TRACK) USE INCLUDING NEW MECHANICAL H$319,530
25-25829-HVAC2025-08-27Mechanical / HVAC6450 S Claiborne AveWe are hooking up three (3) units to facility temporary indoor practice facility. The three (3) units are self-contained, two of the units are 105 ton Trane RTU/AHU units and the o$29,886
25-21142-HVAC2025-07-23Mechanical / HVAC900 Convention Center Blvd, Phase 1 Area 2Demo 13 Chilled Water Air Handling Units. Replace with 9 Chilled Water Air Handling Units. Install 2 New Chilled Water Rooftop Units. Install 14 Electric Heat VAV Boxes. Install 1$6,000,000
25-18335-FGAS2025-06-30Mechanical / HVAC2001 Leon C Simon DrRemove 1 500 Gallon Electric Hot water Heater and replace with a new of the same size. $50,000
24-37315-HVAC2025-05-01Mechanical / HVAC5620 Read BlvdInstall 1 New 300 Ton Chiller Air Cooled$287,000
24-36267-HVAC2024-12-19Mechanical / HVAC717 Orleans AveReplacement of two 125-ton chillers and pumps on the existing steel structure. $330,000
24-35653-HVAC2024-11-26Mechanical / HVAC900 Convention Center Blvd, Phase 1 Area 1Replace 3 Chilled Water Air Handling Units. Installing 1 New Rooftop Unit. Replace 9 Electric Heat VAV Boxes. Includes duct work and piping to new equipment.$1,100,000
24-30662-FGAS2024-10-08Mechanical / HVAC2111 Saint Charles AveLine for Line Replacement of 2 Boilers and 3 Water Heaters located in the Basement$505,143
24-21499-FGAS2024-07-16Mechanical / HVAC2111 Saint Charles AveMechanical fuel gas permit for 2 electric water heater. $4,500
24-21492-HVAC2024-07-16Mechanical / HVAC2111 Saint Charles AveInstallation of ductwork and mechanical piping for ground level and level one. This includes 8 DX split systems, 6 exhaust fans, 4 water source heat pump units and 3 dehumidifiers.$237,000
24-09838-FGAS2024-04-24Mechanical / HVAC1301 Audubon StRunning approximately 200' of new Gas line for 3 New Generators 25,000 KW each. All located at the Central Plant. Generators are filed for in the Building Permit. $15,000
24-06302-FGAS2024-03-08Mechanical / HVAC1700 Perdido StRun approximately 100" of New Gas Line to 200kw generator$20,000
24-06534-FGAS2024-03-08Mechanical / HVAC1430 Tulane AveRun approximately 200' of new gas line$20,000
24-06362-FGAS2024-03-08Mechanical / HVAC1440 Canal Strun approximately 100" of new Gas piping to generator$20,000
24-06553-FGAS2024-03-08Mechanical / HVAC145 Elk PlRun approximately 100' of new gas line to generator$20,000
24-00844-HVAC2024-01-31Mechanical / HVAC27 McAlister DrMechanical Filing for 7 story building to include all Mechanical equipment Associated Ductwork and Piping, 59 VAV's$1,750,000
24-00848-HVAC2024-01-31Mechanical / HVAC2400 Wall AlyMechanical Filing for 6 story building to include all associated ductwork and mechanical piping. Includes 49 VAVs$1,750,000
24-00981-FGAS2024-01-31Mechanical / HVAC27 McAlister DrGas Piping for New 7 Story Building$1,750,000
24-00900-FGAS2024-01-31Mechanical / HVAC2400 Wall Alygas piping for 6 Story Building. Run 300ft of new Gas Line in 2 New Bldgs.3 Electric Water Heaters, 1 Generators.$1,750,000
23-25810-HVAC2023-11-06Mechanical / HVAC160 Engineering RdNew HVAC system to include 42- VAVs located, 2- Rooftop Units, 2- Outside Air Rooftop Units, 1 Air handler on the first floor, 27- Vertical Fan Coil Units, 1 VRF condenser with 7- $1,160,000
23-25799-FGAS2023-10-24Mechanical / HVAC160 Engineering RdInstallation of gas line from existing meter location to the roof of the building. This gas line will feed (1) one generator. Includes two water heaters.$111,100
23-19179-FGAS2023-07-21Mechanical / HVAC2950 Ben Weiner DrRun New reconnecting gas lines to new Boilers. (2)$65,000
23-19479-HVAC2023-07-21Mechanical / HVAC1751 Gentilly Blvd Bldg 14install 14 new window units 8000 BTU'S ea.,$25,000
23-19484-HVAC2023-07-21Mechanical / HVAC1751 Gentilly Blvd Bldg 20Install 14 Window Units 8000 BTU'S ea.$25,000
23-18208-HVAC2023-07-11Mechanical / HVAC900 Convention Center BlvdRemoving existing AC grilles and Diffusers and Installing new AC grilles and diffusers$275,000
23-09400-HVAC2023-04-28Mechanical / HVAC2111 Saint Charles AveReplace 2-AC and AHU, Install 2 mini-splits$0
21-25147-FGAS2022-05-24Mechanical / HVAC2700 Napoleon Averoof 2-Boilers, 2 Elec. Duct & Heaters, 2 Evp. Tanks,, 2-Generator-Hook up only (generators (furnished by others), 3 Gas Lines. All installed in Central Plantand gas line. Located$4,249,979
21-14861-FGAS2021-05-25Mechanical / HVAC31 McAlister DrInstall 2 - Steam Powered HWHS, 2 Exp.Tanks$0
21-14870-HVAC2021-05-25Mechanical / HVAC31 McAlister DrINSTALL 4TH FLOOR; 50-FCUS, (19-FCUS DORM ROOMS, 5-FCUS BLDG USE A AREA AND 22-FCUS DORM ROOM, 4-FCUS BLDG USE B AREAS)$0
21-14867-HVAC2021-05-25Mechanical / HVAC31 McAlister DrINSTALL 2ND FLOOR; 38 - FCUS, (18-FCUS DORM ROOMS, 3-FCUS BLDG USE-A AREA AND 9 FCUS DORM ROOMS, 8-FCUS BLDG USE) B AREA$0
21-14862-HVAC2021-05-25Mechanical / HVAC31 McAlister DrInstall 1 FIRST FLOOR ALL FOR BLDG. USE.; 7 AHUS, 31 VAVS, 11 FCUS, (3-AHUS, 24 VAVS,5 FCUS - A AREA AND 4 AHUS, 7 VAVS, 6 FCUS - B AREA)$0
21-14869-HVAC2021-05-25Mechanical / HVAC31 McAlister DrINSTALL 3RD FLOOR; 50-VCUS, (19-FCUS DORM ROOMS, 5-FCUS, BLDG USE - A AREA AND 21-FCUS DORM ROOM, 5-FCUS BLDG USE B AREA)$0
21-14880-HVAC2021-05-21Mechanical / HVAC31 McAlister DrINSTALL 7TH FLOOR; 38 FCUS; 17-FCUS DORM ROOMS, 5-FCUS BLDG USE A AREA AND 12-FCUS DORM ROOMS, 4-FCUS BLDG USE B AREA$0
21-14878-HVAC2021-05-21Mechanical / HVAC31 McAlister DrINSTALL 6TH FLOOR; 38-FCUS; 15-FCUS DORM ROOMS 5-FCUS BLDG USE A AREA AND 14-FCUS DORM ROOMS, 4-FCUS BLDGUSE B AREA)$0
21-14877-HVAC2021-05-21Mechanical / HVAC31 McAlister DrINSTALL 5TH FLOOR; 49 FCUS, 19-CUS DORM ROOMS, 5-FUCS BLDG USE A AREA AND 20-FCUS DORM ROOMS, 5-FUCS BLDG USE B AREA$0
21-14875-HVAC2021-05-21Mechanical / HVAC31 McAlister DrINSTALL ROOF; 4 water source DOAS.. (2-DOAS A AREA AND 2-DOAS B AREA)$0
20-42943-HVAC2020-10-07Mechanical / HVAC7001 Freret StInstall 8CW vav w/electric heat, 2 vav's electric heat only adn 1 oau-2cw w/steam heating$0
20-40295-HVAC2020-09-10Mechanical / HVAC1222 Jena StReplace old ductwork with new install 2 dehumidifiers $17,800

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public New Orleans permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →