COMPANY RECORD · SEATTLE, WA
Umc, Inc. — permit history in Seattle, WA
Umc, Inc. appears on 276 Seattle permit records from 2018 through 2026, most often mechanical / hvac (99.6% of the record).
Permit categories
| Category | Permits | Share |
|---|---|---|
| Mechanical / HVAC | 275 | 99.6% |
| Electrical | 1 | 0.36% |
2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.
Activity by year
| Year | Permits issued |
|---|---|
| 2018 | 9 |
| 2019 | 35 |
| 2020 | 23 |
| 2021 | 22 |
| 2022 | 57 |
| 2023 | 50 |
| 2024 | 28 |
| 2025 | 38 |
| 2026 | 14 |
Busiest year on record: 2022, with 57 permits. One project can account for several filings, so read this as filing activity rather than workload.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 1551 EASTLAKE AVE E | 2026-08-25 |
| 333 DEXTER AVE N | 2026-07-20 |
| 1165 EASTLAKE AVE E | 2026-03-31 |
| 7500 SEWARD PARK AVE S | 2026-03-05 |
| 3310 CASCADIA AVE S | 2026-02-27 |
| 1560 N 115TH ST | 2026-02-20 |
| 1700 7th AVE | 2026-02-05 |
| 7861 62ND AVE NE | 2026-01-29 |
| 1303 NE 45TH ST | 2026-01-21 |
| 1101 DEXTER AVE N | 2026-01-15 |
| 1511 3RD AVE | 2025-11-18 |
| 921 TERRY AVE | 2025-08-22 |
| 1100 FAIRVIEW AVE N | 2025-08-01 |
| 819 VIRGINIA ST | 2025-07-29 |
114 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $0 to $3,000,000, median $25,676. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
276 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| 7159735-RF | 2026-08-25 | Mechanical / HVAC | 1551 EASTLAKE AVE E | Installation of a 3-ton split unit | $20,000 |
| 7144182-ME | 2026-07-20 | Mechanical / HVAC | 333 DEXTER AVE N | Relocating a Type 2 hood that serves only water exhaust to a blower dryer; no grease exhaust. Extending ductwork to new hood location, per plan. | $36,524 |
| 7135619-RF | 2026-03-31 | Mechanical / HVAC | 1165 EASTLAKE AVE E | Due to the robust growth of Adaptive's customer base, sample freezer space is in short supply. Adding more freezers will not simplify but complicate an already crowded process. The | $117,000 |
| 7131924-RF | 2026-03-05 | Mechanical / HVAC | 7500 SEWARD PARK AVE S | The existing LG VRF Systems are using R410a refrigerant. This refrigerant, R410a, and the parts for this LG equipment will be phased out starting this year, causing repair costs | $268,252 |
| 7130801-FR | 2026-02-27 | Mechanical / HVAC | 3310 CASCADIA AVE S | Replace Boiler at Arch Bishop Residence Current system is down. We will be replacing Triangle Tube Boiler with boiler and equipment listed below. - NAVI-NHB-150H Condensing Boiler | $18,000 |
| 7079038-ME | 2026-02-20 | Mechanical / HVAC | 1560 N 115TH ST | Provide and install replacement chiller for replacement Linac. Add two addition VAV for supplement cooling, per plans | $50,062 |
| 7113529-ME | 2026-02-05 | Mechanical / HVAC | 1700 7th AVE | Alterations to mechanical system on existing commercial building, per plans. | $200,000 |
| 7127138-RF | 2026-01-29 | Mechanical / HVAC | 7861 62ND AVE NE | TI - Addition of one split system; Phase 2 only | $4,183 |
| 7125250-BP | 2026-01-21 | Mechanical / HVAC | 1303 NE 45TH ST | Isolation of system to keep old system operational to keep heat in building and demo old unit. UMC will install a Burnham KV904ASNL, Knockdown, cast iron sectional, 15 PSI Low Pres | $101,759 |
| 7124509-BP | 2026-01-15 | Mechanical / HVAC | 1101 DEXTER AVE N | Installation of a thermal expansion tank | $6,800 |
| 7124507-BP | 2026-01-15 | Mechanical / HVAC | 1101 DEXTER AVE N | Installation of a 1000 gallon storage tank | $23,500 |
| 7124503-BP | 2026-01-15 | Mechanical / HVAC | 1101 DEXTER AVE N | installation of a 500 gallon storage tank | $12,500 |
| 7124501-BP | 2026-01-15 | Mechanical / HVAC | 1101 DEXTER AVE N | Installation of a 500 gallon storage tank | $12,500 |
| 7124495-BP | 2026-01-15 | Mechanical / HVAC | 1101 DEXTER AVE N | Installation of an electric water heater | $42,000 |
| 7087260-ME | 2025-12-10 | Mechanical / HVAC | 1101 DEXTER AVE N | Installation of an electric powered heat pump water heater | $500,000 |
| 7103158-ME | 2025-11-18 | Mechanical / HVAC | 1511 3RD AVE | Replacing a split unit STFI (Subject to Field Inspection) | $7,000 |
| 7114407-RF | 2025-10-30 | Mechanical / HVAC | 7500 SEWARD PARK AVE S | Kline Galland Home is being proactive in replacement of aging LG VRF systems. The last system replacement (#10) was replaced in March of 2024. CURRENT SYSTEM DESCRIPTION The | $246,708 |
| 7077109-BP | 2025-09-24 | Mechanical / HVAC | 1101 DEXTER AVE N | Like for like replacement of a gas water heater. Future decarbonization plan required before final inspection. | $24,361 |
| 7077117-BP | 2025-09-24 | Mechanical / HVAC | 1101 DEXTER AVE N | Like for like gas water heater replacement. Future decarbonization plan required before final inspection. | $24,361 |
| 7095105-ME | 2025-08-22 | Mechanical / HVAC | 921 TERRY AVE | Alterations to mechanical system of existing commercial building, per plans. | $56,000 |
| 7103168-RF | 2025-08-22 | Mechanical / HVAC | 1511 3RD AVE | Replacement of a split unit | $7,000 |
| 7080987-ME | 2025-08-01 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | provide and install 2 new terminal units for new TC lab. per plans | $25,000 |
| 7085495-ME | 2025-07-29 | Mechanical / HVAC | 819 VIRGINIA ST | Replace 15 ton hydronic heat pump with a new R-454 heat pump, per plans. | $45,000 |
| 7070926-ME | 2025-07-21 | Mechanical / HVAC | 1200 WESTLAKE AVE N | Replace two gas pack units with heat pumps, per plan. | $17,500 |
| 7084604-ME | 2025-07-14 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Installing (9) new supply diffusers, (6) new exhaust grilles, (1) 8'" Terminal unit, install 40' of stainless exhaust duct serving (1) gross station, install (1) Nederman arm. per | $68,000 |
| 7062175-ME | 2025-07-02 | Mechanical / HVAC | 1208 EASTLAKE AVE E | Lab expansion will include upgrading the mechanical system to provide and support new equipment services and loads. per plans | $300,000 |
| 7066853-ME | 2025-06-30 | Mechanical / HVAC | 1400 DISCOVERY PARK BLVD | Effluent Pump Station gate replacement, per plan. | $600,000 |
| 7057319-ME | 2025-06-04 | Mechanical / HVAC | 1550 N 115TH ST | Install remote Air Cooled condenser, Chiller, and chilled water piping to support new Linear Accelerator installation. | $47,522 |
| 7088268-RF | 2025-05-29 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Installing (2) new rooftop AC units and (2) indoor units mechanical permit 7069148-ME | $9,000 |
| 7088376-RF | 2025-05-29 | Mechanical / HVAC | 207 PONTIUS AVE N | Replacing (2) roof top units and (2) branch controllers mechanical permit 7073752-ME | $15,000 |
| 7087874-RF | 2025-05-28 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Installing a new split unit. mechanical permit mechanical permit 7070257-ME | $5,000 |
| 7087929-RF | 2025-05-28 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | (1) existing condensing unit on the rooftop of of the Fairview Building located on Fred Hutch Campus. | $12,137 |
| 7079998-ME | 2025-05-27 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Altering the exhaust and supply system in order to repurpose the existing storage room to accommodate the new clinical processing space, per plan. | $75,000 |
| 7069148-ME | 2025-05-20 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Replacing (2) existing split units serving 1000 Fairview Ave N, Seattle | $41,500 |
| 7085829-RF | 2025-05-14 | Mechanical / HVAC | 7861 62ND AVE NE | TI - Addition of one split system; Phase 1 only | $3,000 |
| 7055291-ME | 2025-05-13 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Replacing (4) AC units on the roof of the Fairview building on Fred Hutch Campus, per plans. | $178,000 |
| 7079890-ME | 2025-05-13 | Mechanical / HVAC | 900 UNIVERSITY ST | 5t HP Heat Pump like for like equipment replacement on the roof, per plan. | $9,000 |
| 7074481-ME | 2025-05-08 | Mechanical / HVAC | 1300 5TH AVE | Mechanical - Refrigeration Permit needed. Appliance Type: Heat Pump Heat Source: Electric/ replacing the appliance w/ same fuel type ** Need an intake date ASAP | $45,792 |
| 7076242-ME | 2025-04-29 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | install of (1) new supply and (1) exhaust terminal units in A2-111 and install of (1) new supply and (1) exhaust terminal units in A2-112, per plans | $25,000 |
| 7055275-ME | 2025-04-29 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Replacing (4) A/C units located at the Minor building on Fred Hutch Campus, per plans. | $120,000 |
| 7064538-ME | 2025-04-28 | Mechanical / HVAC | 825 EASTLAKE AVE E | Refurbishment of AHU-4 at FHCC Clinic 1 per plans | $250,000 |
| 7070257-ME | 2025-04-25 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Replacing an existing split unit serving building G elevator machine room | $17,500 |
| 7082407-RF | 2025-04-24 | Mechanical / HVAC | 900 UNIVERSITY ST | Refrigeration permit for new line set | $8,000 |
| 7057308-ME | 2025-04-16 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Installing new coils and fan aray's in an existing air handler unit | $250,000 |
| 7074493-RF | 2025-03-11 | Mechanical / HVAC | 1300 5TH AVE | Refrigeration permit for new line sets. | $3,000 |
| 7030027-ME | 2025-02-28 | Mechanical / HVAC | 911 PINE ST | Replace 2 existing AC package units serving the theater, per plans. | $200,000 |
| 7060456-ME | 2025-02-17 | Mechanical / HVAC | 1100 FAIRVIEW AVE N | Installing supply terminal units and exhaust terminal units per plans | $26,000 |
| 7047847-ME | 2025-02-10 | Mechanical / HVAC | 7861 62ND AVE NE | TI - Addition of two split system heat pumps and some bathroom ventilation. | $58,250 |
| 7044962-ME | 2025-01-29 | Mechanical / HVAC | 1531 UTAH AVE S | Replacing an old Air Handling Unit with a new one in the mechanical room, per plan. | $14,000 |
| 7018418-ME | 2025-01-29 | Mechanical / HVAC | 600 NW Bright ST | Replace (6) gas package RTUs with heat pump RTUs, per plan. | $150,000 |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Seattle permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →