COMPANY RECORD · SEATTLE, WA
Ion Tech — permit history in Seattle, WA
Ion Tech appears on 133 Seattle permit records from 2015 through 2026, all of them electrical.
Permit categories
| Category | Permits | Share |
|---|---|---|
| Electrical | 133 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2015 | 33 |
| 2016 | 23 |
| 2017 | 9 |
| 2018 | 12 |
| 2019 | 11 |
| 2020 | 5 |
| 2021 | 1 |
| 2022 | 5 |
| 2023 | 6 |
| 2024 | 11 |
| 2025 | 11 |
| 2026 | 6 |
Busiest year on record: 2015, with 33 permits. One project can account for several filings, so read this as filing activity rather than workload.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 2335 BOYLSTON AVE E | 2026-04-24 |
| 10055 41ST AVE NE | 2026-03-25 |
| 5011 15TH AVE NW | 2026-03-19 |
| 5846 57TH AVE NE | 2026-03-11 |
| 913 N 35TH ST | 2026-01-27 |
| 2919 NE 53RD ST | 2026-01-07 |
| 1940 SW DAWSON ST | 2025-11-07 |
| 5602 39TH AVE W | 2025-07-09 |
| 2315 S JUDKINS ST | 2025-06-29 |
| 2307 S JUDKINS ST | 2025-06-29 |
| 3820 47TH AVE SW | 2025-06-09 |
| 1516 4TH AVE W | 2025-05-07 |
| 2009 S NORMAN ST | 2025-03-26 |
| 905 N NORTHLAKE WAY | 2024-10-04 |
95 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $0 to $10,000,000, median $6,000. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
133 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| 7139999-EL | 2026-04-24 | Electrical | 2335 BOYLSTON AVE E | Altered 2 circuits for 2 emergency elevator smoke shutters | |
| 7135227-EL | 2026-03-25 | Electrical | 10055 41ST AVE NE | Rewire job/Remodel plus new build | |
| 7090745-EL | 2026-03-19 | Electrical | 5011 15TH AVE NW | 5 story multi-family apodment [6-12-25 DR - 132 Sleeping rooms, 4 Live work dwellings] | $645,000 |
| 7133095-EL | 2026-03-11 | Electrical | 5846 57TH AVE NE | Install 3 patio heaters, install 2-4 can lights over bbq, Provide 40amp circuit to panel with 30amp/20amp breakers for sauna and cold plunge. | |
| 7126790-EL | 2026-01-27 | Electrical | 913 N 35TH ST | [CJK 6/3/2026 - One additional circuit added to permit.] | |
| 7124039-EL | 2026-01-07 | Electrical | 2919 NE 53RD ST | ||
| 7121118-EL | 2025-12-12 | Electrical | 10055 41ST AVE NE | Ufer | $250 |
| 7116615-EL | 2025-11-13 | Electrical | 5011 15TH AVE NW | Temp power for multi family project[11/26/2025 JBC Added Second 200amp Temp Power to Permit] | $2,500 |
| 7115895-EL | 2025-11-07 | Electrical | 1940 SW DAWSON ST | Altered 5 circuits Add new service panel/meter | $9,000 |
| 7095444-EL | 2025-07-09 | Electrical | 5602 39TH AVE W | Remodel [3/10/2026 PGF Added 100A feeder] | $50,000 |
| 7093721-EL | 2025-06-29 | Electrical | 2315 S JUDKINS ST | Ufer permit and inspeciton | $250 |
| 7093722-EL | 2025-06-29 | Electrical | 2307 S JUDKINS ST | UFER permit and inspection; 7/1/25 RN UFER Test Fee Added per Contractors Request | $250 |
| 7090239-EL | 2025-06-09 | Electrical | 3820 47TH AVE SW | upgrading panel and rewiring top floor to remove knob and tube | $13,000 |
| 7085529-EL | 2025-06-05 | Electrical | 2315 S JUDKINS ST | East duplex. [5/13/25 KEF - See plan review permit 7084707-EL for the west 4-plex and service.] | $0 |
| 7084707-EL | 2025-05-13 | Electrical | 2307 S JUDKINS ST | West quadplex including service. [5/13/25 KEF - Plan set approved. See permit 7085529-EL for the east duplex.] | $110,000 |
| 7084450-EL | 2025-05-07 | Electrical | 1516 4TH AVE W | Replacing meter 5/27/2026 AB: Renewal | $3,000 |
| 7077589-EL | 2025-03-26 | Electrical | 2009 S NORMAN ST | triplex; 4/21/25 RN Fees added for UFER Test per last inspectors results | $45,000 |
| 7060159-EL | 2024-12-09 | Electrical | 2307 S JUDKINS ST | Townhouses [4-8-25 DR - Needs Plan Review for each building. This permit shall only be used for a Get Started permit. Service, Feeder & Final inspection removed] | $25,000 |
| 7049609-EL | 2024-10-04 | Electrical | 905 N NORTHLAKE WAY | New heat pump circuit | $1,500 |
| 7047168-EL | 2024-09-20 | Electrical | 2009 S NORMAN ST | Ufer inspection | $250 |
| 7044870-EL | 2024-09-09 | Electrical | 2307 S JUDKINS ST | Temp pole | $500 |
| 7044045-EL | 2024-09-04 | Electrical | 5122 47TH AVE NE | Heat pump. Car charger | $2,500 |
| 7043072-EL | 2024-08-27 | Electrical | 802 NE 43RD ST | Wire unit [9/10/2024 JBC Added devices to permit, this is a full new unit wire in the Northwest building corner on street level. Note building permit is 6976369-CN for added unit.] | $8,500 |
| 7041042-EL | 2024-08-15 | Electrical | 5122 47TH AVE NE | Altering heat pump circuit | $500 |
| 7031775-EL | 2024-07-01 | Electrical | 2335 BOYLSTON AVE E | 75 unit multi family apodment [6-21-24 DR - This is a Boarding House, note up to level 3 is Type IA construction][07/01/24 BGO - Approved Plan Set] [08/19/24 Approved Revision] [12 | $275,000 |
| 7032745-EL | 2024-06-26 | Electrical | 2728 GARLOUGH AVE SW | New ac and heater circuits/dc [C.Kenefick 7/18/2025 - 200a service added to permit.] | $2,500 |
| 7014808-EL | 2024-03-17 | Electrical | 3036 20TH AVE S | Rewiring basement | $7,500 |
| 7012878-EL | 2024-03-05 | Electrical | 2627 34TH AVE W | Changed out 35ish switches and installed smart switches. Moved car charger. | $2,500 |
| 6996874-EL | 2023-11-17 | Electrical | 4049 LATONA AVE NE | Added circuits for two heat pumps | $3,000 |
| 6986638-EL | 2023-10-13 | Electrical | 1800 M L KING JR WAY S | Electrical for 14 unit apartments. [10/13/23 JK APPROVED PLANS.] | $200,000 |
| 6986049-EL | 2023-09-14 | Electrical | 2335 BOYLSTON AVE E | Temp pole | $1,500 |
| 6937555-EL | 2023-01-31 | Electrical | 10501 MIDVALE AVE N | 60+ unit Apodment | $250,000 |
| 6944915-EL | 2023-01-27 | Electrical | 1800 M L KING JR WAY S | Temp power pole | $1,500 |
| 6942419-EL | 2023-01-12 | Electrical | 4750 54TH AVE SW | Adding lighting and 2 circuits | $1,200 |
| 6937556-EL | 2022-12-16 | Electrical | 2807 S HANFORD ST | 30+ unit Apodment | $200,000 |
| 6925694-EL | 2022-10-03 | Electrical | 2260 NE 53RD ST | Upgrading the panels for the building. 7 in total | $20,000 |
| 6890840-EL | 2022-03-28 | Electrical | 3816 11TH AVE W | Kitchen remodel. Add washer and dryer. Upgrade panel | $10,000 |
| 6876347-EL | 2022-01-06 | Electrical | 1130 N NORTHGATE WAY | Temp pole | $500 |
| 6876342-EL | 2022-01-06 | Electrical | 1116 N NORTHGATE WAY | We are changing the service drop location and upgrading the service gear and feeders | $5,000 |
| 6818236-EL | 2021-01-11 | Electrical | 2305 S PLUM ST | Wall cover permit while FA permit is being reviewed | $10,000 |
| 6779345-EL | 2020-07-15 | Electrical | 2305 S PLUM ST | 5 Story Boarding House | $397,500 |
| 6785759-EL | 2020-06-08 | Electrical | 10610 MERIDIAN AVE N | user test for multi family project | $225,000 |
| 6785093-EL | 2020-06-02 | Electrical | 2305 S PLUM ST | laying conduit | $1 |
| 6773544-EL | 2020-02-26 | Electrical | 2000 23RD AVE S | Temp.pole | $150 |
| 6772537-EL | 2020-02-19 | Electrical | 2305 S PLUM ST | Temp power service 1/21/2021 jnl renewal | $10,000,000 |
| 6749775-EL | 2019-09-24 | Electrical | 151 WARD ST | New residence | $24,000 |
| 6743096-EL | 2019-08-13 | Electrical | 1222 POST AL | Add new lights and outlets for new taproom | $6,000 |
| 6741058-EL | 2019-08-01 | Electrical | 4520 7TH AVE NE | Ufer test | $150 |
| 6739445-EL | 2019-07-23 | Electrical | 10610 MERIDIAN AVE N | temp pole | $250 |
| 6730450-EL | 2019-06-05 | Electrical | 10610 MERIDIAN AVE N | New Multi Family Apartment | $175,000 |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Seattle permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →