COMPANY RECORD · SEATTLE, WA

Cintas Fire Protection — permit history in Seattle, WA

Cintas Fire Protection appears on 53 Seattle permit records from 2016 through 2026, all of them electrical.

Permit categories

CategoryPermitsShare
Electrical53100%

Activity by year

YearPermits issued
20164
201724
20185
20202
20211
20231
20243
20258
20265

Busiest year on record: 2017, with 24 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
6021 ROOSEVELT WAY NE2026-10-12
900 12TH AVE2026-09-14
2012 NE 45TH ST2026-07-09
2441 N NORTHLAKE WAY2026-07-09
7110 EAST GREEN LAKE DR N2026-07-09
756 JOHN ST2025-12-24
925 E PIKE ST2025-11-21
8511 15TH AVE NE2025-11-21
4020 AURORA AVE N2025-09-24
9830 40TH AVE S2025-08-11
4744 12TH AVE NE2025-06-11
200 6TH AVE N2025-05-19
300 ROY ST2025-03-25
607 MAYNARD AVE S2024-12-30

40 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $1,500 to $11,000, median $4,000. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Also named on permits at the same addresses

CompanyShared addressesYears
Adt LLC62015–2026
Titan Electric Inc42017–2025
Brimstone Fire Safety32017–2025
Ozz Electric Wa Inc32015–2019
Sea-Tac Electric Inc22017–2026
Seacom Cabling Inc22016–2024
Macdonald Miller Facility Solutions LLC22017–2026
NW Security & Sound LLC22016–2025

Companies that also appear in Seattle permit records at addresses where Cintas Fire Protection filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.

Permits on record

53 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
7167038-EL2026-10-12Electrical6021 ROOSEVELT WAY NEInstallation of a Napco Starlink MAX2-CFBPS cellular monitoring panel for fire alarm monitoring
7162574-EL2026-09-14Electrical900 12TH AVEInstalling Starlink Cellular Panel to convert monitoring from failing POTS to Cellular for the fire alarm system. No other changes to existing system
7152257-EL2026-07-09Electrical2012 NE 45TH STInstalling a cellular Starlink MAX2-CFBPS to transfer monitoring from failing POTS lines
7152260-EL2026-07-09Electrical2441 N NORTHLAKE WAYInstall a Starlink MAX2-CFBPS cellular monitoring panel for fire alarm system.
7152263-EL2026-07-09Electrical7110 EAST GREEN LAKE DR NInstall Starlink MAX2-CFBPS cellular monitoring panel for fire alarm monitoring
7122650-EL2025-12-24Electrical756 JOHN STInstalling Starlink Max2 cellular monitoring panel to take over POTS monitoring$3,000
7118038-EL2025-11-21Electrical925 E PIKE STInstall a Starlink Cellular monitoring panel to take over from POTS for Fire Alarm Monitoring$2,500
7118039-EL2025-11-21Electrical8511 15TH AVE NEInstalling Starlink Cellular Communicator to transfer from POTS for Fire Alarm Monitoring$2,500
7108546-EL2025-09-24Electrical4020 AURORA AVE NInstall a Starlink MAX2 cellular communicator to transition from POTS monitoring of the fire alarm control panel$4,500
7101069-EL2025-08-11Electrical9830 40TH AVE SInstall a Starlink Max2 cellular monitoring panel to convert fire alarm monitoring from POTS$4,500
7090795-EL2025-06-11Electrical4744 12TH AVE NEreplacing a failed SK-5495 NAC Expander Panel with PS6$3,000
7086584-EL2025-05-19Electrical200 6TH AVE NInstall Cellular Monitoring Unit (Starlink MAX2) to transition form failing POTs lines to Cellular Communication$1,500
7077354-EL2025-03-25Electrical300 ROY STReplacing failing expander panel on 2nd floor. no other work to be completed$3,000
7062789-EL2024-12-30Electrical607 MAYNARD AVE SUpgrading monitoring from non-working AES to Cellular Wireless Napco Starlink Max2$4,500
7062448-EL2024-12-24Electrical4545 42ND AVE SWInstalling a Cellular Communicator to take over Fire alarm Monitoring. Existing AES has poor signal and inoperable.$6,000
7053511-EL2024-10-28Electrical8512 16TH AVE NWInstallation of AES Radio to replace Telco monitoring for Fire Alarm Panel$11,000
6968697-EL2023-06-06Electrical2120 1ST AVE NInstalling a Telguard LTE monitoring panel to take over existing POTS service on the existing fire alarm control panel$5,600
6842506-EL2021-06-08Electrical2040 13TH AVE WReplace Failing discontinued FACP with New Silent Knight$6,000
6815017-EL2020-12-15Electrical1216 6TH AVE NInstallation of AES Radio to take over Fire Alarm Monitoring from on board dialer.$1,500
6807909-EL2020-10-28Electrical9601 8TH AVE NWReplace existing obsolete conventional control panel with new conventional panel$4,000
6644043-EL2018-02-06Electrical520 PIKE STWE WILL BE REPLACING AND RELOCATING 5 FIRE ALARM DEVICE FOR THE NEW TENANT LAYOUT. WE WILL BE UPDATING THE DEVICE TO THE LED STANDARD PER THE BUILDING.
6641958-EL2018-01-24Electrical520 PIKE STWE WILL BE RELOCATING AND INSTALLING 6 NEW FIRE ALARM DEVICES TO PROVIDE SUFFICIENT COVERAGE TO THE CLARK CONSTRUCTION LAYOUT. EACH DEVICE WILL BE THE NEW LED BUILDING STANDARD.
6640093-EL2018-01-16Electrical2524 BOYER AVE EREPLACING THE FIRE ALARM PANEL WITH A SK-4 AND INSTALLING A SMOKE DETECTOR ABOVE THE PANEL.
6638529-EL2018-01-05Electrical520 PIKE STWE WILL BE REMOVING AND REPLACING THE EXISTING FA DEVICES (4) TO THE NEW BUILDING STANDARD FOR THE TENANT IMPROVEMENT. COVERAGE WILL STAY THE SAME.
6638501-EL2018-01-05Electrical520 PIKE STWE WILL REMOVE AND REPLACE (5) FIVE FIRE ALARM DEVICES IN THE TENANT SPACE, PROVIDING A MARKET READY LAYOUT. EACH DEVICE WILL BE THE NEW LED BUILDING STANDARD.
6631257-EL2017-11-20Electrical9021 35TH AVE SWWE WILL BE REPLACING THE CURRENT FIRE ALARM PANEL WITH SILENT KNIGHT 5208, ALL FIELD DEVICES TO STAY THE SAME BUT WE WILL BE CHANGING OUT THE END OF LINE RESISTERS.
6631161-EL2017-11-17Electrical4328 7TH AVE NEWE WILL BE INSTALLING AN AES RADIO TO THE FIRE ALARM CONTROL PANEL TO SUPPLY MONITORING FOR FIRE SYSTEM.
6631075-EL2017-11-17Electrical2328 10TH AVE EWE WILL BE REPLACING THE CURRENT FIRE ALARM PANEL WITH A SILENT KNIGHT SK-4 AND INSTALLING A SMOKE DETECTOR ABOVE THE PANEL.
6631153-EL2017-11-17Electrical520 PIKE STWE WILL BE INSTALLING 2 STROBE DEVICES IN THE OFFICE BUILD OUT AND TI AND REMOVE AND REPLACING 1 DEVICE THAT IS GOING TO THE NEW CONFERENCE ROOM BUILD OUT. DEVICES WILL BE THE NEW
6627621-EL2017-10-31Electrical5644 UNIVERSITY WAY NEREPLACED FIRE ALARM CONTROL PANEL AND INSTALL SMOKE DETECTOR ABOVE PANEL. ALL FIELD DEVICES TO STAY THE SAME.
6624719-EL2017-10-17Electrical7500 EAST MARGINAL WAY SPROVIDING ADDRESSABLE MODULES AND PROGRAMMING FOR WATER FLOW AND TAMPER SWITCHES BEING ADDED DUE TO THE NEW PAINT BOOTH. ALSO TRANSFERRING ADDRESSABLE MODULE FROM OLD PULL STATION
6622040-EL2017-10-02Electrical801 2ND AVECINTAS FIRE WILL BE INSTALLING (2) TWO STROBE DEVICES IN THE NEW BATHROOM ADDITION. 10/5/17 HKH; ADD (2) DEVICES FOR A TOTAL OF 4.
6612519-EL2017-08-09Electrical520 PIKE STMARCHEX SUITE FLOOR 19 AND 20. REPLACING MAIN CORRIDOR DEVICES TO NEW LED STANDARD, INSTALLING 1 SPEAKER STROBE IN NEW SERVER ROOM ON 19TH FLOOR. 08/15/2017 SMR UPDATE LOCATION FRO
6603569-EL2017-06-20Electrical9750 3RD AVE NEINSTALLING OR RELOCATING FIRE ALARM DEVICES TO UPDATE DEVICE COVERAGE FOR CORRIDORS THAT WERE CREATED DUE TO SINGLE OCCUPANT OFFICES BUILD OUT
6598313-EL2017-05-22Electrical1512 SUMMIT AVEREPLACING FIRE ALARM CONTROL PANEL AND INSTALLING A SMOKE DETECTOR ABOVE THE PANEL.
6598387-EL2017-05-22Electrical520 PIKE STREMOVE AND REPLACING 4 STROBES IN THE COMMON AREA BATHROOMS FOR A TI TO NEW BUILDING LED STANDARD FOR FLOORS 20 AND 18.
6598383-EL2017-05-22Electrical520 PIKE STREMOVE AND REPLACING 6 STROBES IN THE COMMON AREA BATHROOMS FOR A TI TO NEW BUILDING LED STANDARD FOR FLOORS 19, 11, AND 27.
6596693-EL2017-05-11Electrical7401 RAINIER AVE SREMOVE AND REPLACE FIRE ALARM CONTROL PANEL WITH SK-4 AND INSTALL A SMOKE DETECTOR ABOVE THE PANEL. ALL OTHER FIELD DEVICES STAY THE SAME.
6595498-EL2017-05-04Electrical520 PIKE STREMOVE AND REPLACE OLD BUILDING DEVICE WITH THE NEW LED BUILDING STANDARD DEVICE IN TENANT SPACE.
6591862-EL2017-04-14Electrical2800 S MASSACHUSETTS STREPLACING OLD DEFECTIVE FIRE PANEL WITH AN SILENT KNIGHT SK-4 AND INSTALLING A SMOKE DETECTOR ABOVE THE FIRE PANEL.
6587800-EL2017-03-23Electrical520 PIKE STREMOVE AND REPLACING OLD BUILDING DEVICES AND INSTALLING (6) NEW LED LINE DEVICES THAT ARE NEW STANDARD FOR THE BUILDING. MARKET READY SUITE
6586744-EL2017-03-17Electrical4634 EAST MARGINAL WAY SWE WILL BE TERMINATING 2 FIRE ALARM DEVICES ON THE DRY SPRINKLER SYSTEM TO THE FIRE PANEL, LOCATED AT THE RISER.
6585968-EL2017-03-14Electrical801 2ND AVEPROVIDE AND INSTALL TWO MONITOR MODULES IN THE 17TH FLOOR ELECTRICAL ROOM WHERE THE DAS SYSTEM IS LOCATED. PROGRAM FOR SUPERVISORY SIGNALS OF DAS SYSTEM.
6582498-EL2017-02-22Electrical520 PIKE STREMOVE AND REPLACING 3 SPEAKER STROBES AND ADDING 2 STROBES TO ACCOMMODATE NEW TI LAYOUT
6578620-EL2017-01-30Electrical1401 1ST AVE[JOINT VENTURE WITH TITAN ELECTRIC INC. ] REVISING THE COMMON AREA SPEAKERS TO ACCOMMODATE RENOVATIONS
6578597-EL2017-01-30Electrical3300 W MCGRAW STRELOCATING (1) CEILING MOUNT HORN STROBE TO ACCOMMODATE NEW TENANT, INSTALL (4) CEILING MOUNT STROBES, INSTALL (1) NOTIFICATION EXPANDER TO POWER THE NEW DEVICES.
6578356-EL2017-01-27Electrical1221 HARBOR AVE SWNEED TO INSTALL SILENT KNIGHT SK-4 FIRE ALARM PANEL AND REPLACE BATTERIES IN FIRE PANEL.
6578338-EL2017-01-27Electrical3230 EASTLAKE AVE EWE WILL BE INSTALLING A SILENT KNIGHT 5208 FIRE ALARM PANEL, AND REPLACING THE BATTERIES.
6573101-EL2017-01-12Electrical520 PIKE STTENANT IMPROVEMENT, RELOCATE, UPGRADE FIRE ALARM DEVICES TO ACCOMDATE NEW LAYOUT, PER PLAN
6570552-EL2016-12-08Electrical1415 1ST AVEINSTALLATION OF 5 FIRE ALARM SPEAKERS TO ACCOMMODATE NEW TENANT LAYOUT

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Search these records

The 53 permits above are a static record through 2026. Select a year above to open that year’s records, or search Cintas Fire Protection in Seattle, WA by address, trade or date range.

Source and limits

Public Seattle permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →

Is this your company? Show this public permit record on your website with a free badge.