COMPANY RECORD · SEATTLE, WA

Archer Construction — permit history in Seattle, WA

Archer Construction appears on 89 Seattle permit records from 2018 through 2026, all of them fire protection.

Permit categories

CategoryPermitsShare
Fire protection89100%

Activity by year

YearPermits issued
20189
20197
20208
20217
202211
20236
20248
202515
202618

Busiest year on record: 2026, with 18 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
5700 24TH AVE NW2026-08-11
104 12TH AVE2026-08-07
4601 6TH AVE S2026-07-24
5701 1ST AVE S2026-07-23
2500 SW BARTON ST2026-07-23
2925 E MADISON ST2026-07-13
1518 NW 52ND ST2026-07-09
3870 MONTLAKE BLVD NE2026-05-19
7561 63rd AVE NE2026-05-15
5001 25TH AVE NE2026-04-27
6038 Martin Luther King Jr WAY S2026-03-20
124 ROY ST2026-02-20
2208 4TH AVE2026-02-18
2006 S WELLER ST2026-02-09

69 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $0 to $409,215, median $7,679. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

89 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
7157512-FS2026-08-11Fire protection5700 24TH AVE NWRelocate / add 21 sprinklers for new pharmacy$20,904
7157158-FS2026-08-07Fire protection104 12TH AVErelocate / add 4 sprinklers for TI$5,878
7145417-FS2026-07-24Fire protection4601 6TH AVE SChange out existing 8k upright sprinkler heads with new 11.2k sprinkler heads to accommodate new storage racks.$16,736
7154542-FS2026-07-23Fire protection5701 1ST AVE Srelocate 2 heads for new work$3,520
7154543-FS2026-07-23Fire protection2500 SW BARTON STadd / relocate 3 heads for new work$5,256
7151110-FS2026-07-13Fire protection2925 E MADISON ST***This is a revision to an existing approved permit and the permit number 7142311-FS***. Approved permit plan shows adding heads under new awnings that are less wide than 4'-0". $44,168
7150237-FS2026-07-09Fire protection1518 NW 52ND STRun 4" DI from property line to finished floor flange just inside building. Install DCVA backflow at floor flange.$18,300
7142311-FS2026-06-01Fire protection2925 E MADISON STModifying existing overhead fire sprinkler system to accommodate new tenant walls & ceilings.$43,256
7143889-FS2026-05-19Fire protection3870 MONTLAKE BLVD NEModify existing overhead fire sprinkler system to accomodate new walls and ceilings.$5,082
7143483-FS2026-05-15Fire protection7561 63rd AVE NEAdd heads in existing room with new ceiling to be added.$10,269
7135942-FS2026-04-27Fire protection5001 25TH AVE NEModify existing overhead fire sprinkler system to accommodate new tenant walls & ceilings.$30,646
7126893-FS2026-03-20Fire protection6038 Martin Luther King Jr WAY SModify existing overhead fire sprinkler system to accommodate new wall, ceiling, and new mezzanine layout. Provide new dry pendent heads in (2) new walk-in coolers & (1) new walk-$18,825
7130238-FS2026-02-20Fire protection124 ROY STModifying existing overhead fire sprinkler system to accommodate new walls & ceilings.$8,621
7127870-FS2026-02-18Fire protection2208 4TH AVETHIS IS A REVISION TO ISSUED PERMIT 7125287-FS. - Added hydraulic calculations due to extending existing piping per architect request.$9,545
7127117-FS2026-02-09Fire protection2006 S WELLER STTHIS IS A REVISION TO ISSUED PERMIT 7101620-FS PER SEATTLE REVIEW COMMENT (Jordon Foster), DELETE PROPOSED GWB DRAFTSTOP, EXTEND UP-SIZED BRANCH TO FEED ADDITIONAL HEAD ON SOUTH S$178,000
7126892-FS2026-01-28Fire protection4550 42ND AVE SWModifying existing overhead fire sprinkler system to accommodate new tenant walls & ceilings.$3,780
7125287-FS2026-01-16Fire protection2208 4TH AVEModifying existing overhead fire sprinkler system to accommodate new tenant walls & ceilings.$9,545
7123461-FS2026-01-05Fire protection6100 6TH AVE SModify existing overhead fire sprinkler system to accommodate new tenant walls & ceilings.$10,096
7118940-FS2025-12-01Fire protection425 VINE STDemo (3) existing heads at existing elevator$700
7117898-FS2025-11-21Fire protection2500 SW BARTON STModify existing overhead fire sprinklers to accomodated new Starbucks Kiosk$3,300
7117402-FS2025-11-19Fire protection5959 CORSON AVE SModifying existing overhead fire sprinkler system to accommodate new walls & ceilings.$2,412
7113261-FS2025-10-30Fire protection2300 26TH AVE SChange out existing standard response 11.k Standard Response Storage upright sprinklers, with new 8k Quick Response SSP sprinklers in pickleball space. Replace existing alarm valv$18,245
7111115-FS2025-10-10Fire protection2300 26TH AVE SModify existing overhead Fire Sprinkler System such that Suite 200B offoice sprinklers are fed only from the Suite 200B riser. Change out heads to higher temperature near (4) Unit$15,100
7105203-FS2025-10-08Fire protection2300 26TH AVE SModify existing overhead fire sprinkler system to accommodate new wall and ceiling layout at: 1) existing modified lvl 1 office office with existing ceiling grid to remain. 2) new $15,851
7101620-FS2025-09-29Fire protection2006 S WELLER STUpgrade overhead fire sprinkler system per insurance carrier recommendations. Archer Construction's starting point is at the connection to overhead main and branch piping.$5,779
7107414-FS2025-09-18Fire protection2300 26TH AVE SChange out existing standard response pendent sprinklers in office area ceilings to quick response. Modify overhead fire sprinkler system to correct existing coverage deficiencies$13,900
7104176-FS2025-09-04Fire protection2300 26TH AVE SREVISION TO ISSUED PERMIT 7067764-FS: At Storage Room 110, no work was done, as originally submitted due to no new ceiling was installed. At Sprinkler Riser Room, no work was don$22,636
7085374-FS2025-06-25Fire protection1044 4TH AVE SPacific Automation TI is an existing building undergoing tenant improvement. Our scope of work is to provide sprinkler coverage for the new drop-in ceiling grids on the third floor$11,367
7083956-FS2025-05-27Fire protection549 S RIVER STReplace (12) existing 11.2k upright heads with new 16.8k upright heads in new Battery Storage/Charging Room. Provide new hydraulic calculation for Battery Storage room and surroun$5,779
7083949-FS2025-05-22Fire protection603 W CROCKETT STQueen Anne Corner is an existing building which was recently repaired due to fire damage, our scope of work is to provide a new wet sprinkler system. The second floor consists of d$40,000
7069262-FS2025-04-14Fire protection1320 4TH AVEADD AND RELOCATE REQUIRED SPRINKLERS FOR NEW CEILING AND WALL LOCATIONS.$14,607
7069493-FS2025-03-13Fire protection310 FLORENTIA STADD AND RELOCATE REQUIRED SPRINKLERS FOR NEW CEILING AND WALL LOCATIONS.$1,410
7067764-FS2025-03-11Fire protection2300 26TH AVE SModify existing overhead fire sprinkler piping to accommodate new TI walls and ceilings at Existing Office area with new wall and ceiling layout, and new added storage, vestibule a$14,877
7058123-FS2024-12-30Fire protection1518 NW 52ND STProvide new wet interior fire sprinkler system to protect the existing 2 story building. Start point of work is at downstream side of the new backflow installed by others in the b$43,704
7055596-FS2024-12-09Fire protection713 S FIDALGO STADD AND RELOCATE REQUIRED SPRINKLERS FOR NEW CEILING AND WALL LOCATIONS.$12,000
7053037-FS2024-11-12Fire protection6901 FOX AVE SADD AND RELOCATE REQUIRED SPRINKLERS FOR NEW CEILING AND WALL LOCATIONS.$7,106
7049536-FS2024-10-17Fire protection1191 2ND AVEADD AND RELOCATE REQUIRED SPRINKLERS FOR NEW TOILET PARTITION WALLS.$5,567
7045184-FS2024-09-18Fire protection715 Alder STREVISION TO ISSUED PERMIT 6896549-FS Plan shows DCVA backflow moved (from being in underground vault) to inside the building. See sheet 3 plan and Section 'X'. Plan shows butter$13,809
7041537-FS2024-09-04Fire protection944 NW LEARY WAYPROVIDE NEW WET FIRE SPRINKLER SYSTEM TO PROTECT EXISTING BUILDING. 3/5/26 AB: Renewal$35,764
7016887-FS2024-04-01Fire protection549 S RIVER STADD REQUIRED SPRINKLERS FOR NEW CEILING AND WALL LOCATIONS. 10/10/2025 sk renewal$6,965
7006654-FS2024-01-31Fire protection4401 4TH AVE SModify existing overhead fire sprinkler system to accommodate new TI walls and Ceilings.$0
7000498-FS2023-12-15Fire protection2301 5TH AVEAdd and relocate sprinkler heads to accommodate for new walls and ceiling locations.$7,462
6998745-FS2023-12-06Fire protection2006 S WELLER STAdd required sprinklers for new retard box to be added to existing building.$0
6985495-FS2023-09-25Fire protection4722 FAUNTLEROY WAY SWModifying existing sprinkler system to accommodate new walls and ceilings, adding sprinkler heads.$2,975
6982947-FS2023-09-11Fire protection1064 4TH AVE SModify existing sprinkler system to accommodate for new ceiling and walls, Add and relocate sprinkler heads. renewal 03/11/2025 cb$0
6977778-FS2023-07-28Fire protection3223 3RD AVE SRelocate existing heads for new light layout. Change all pendent heads in ceiling areas from standard response to quick response type.$0
6951507-FS2023-04-14Fire protection13201 AURORA AVE NModify existing overhead fire sprinkler system to accommodate new TI walls and ceilings. Revise existing piping in Processing Room to be fed off of wet system, instead of dry syst$0
6896549-FS2022-12-19Fire protection715 ALDER STProvide new fire pump at upper parking level; Install dry sprinkler systems for level: lower parking,& upper parking; Install wet sprinkler systems for levels: L1, L2,& L3; Install$0
6924802-FS2022-11-28Fire protection2615 1ST AVEInstall sprinkler protection to accommodate new floor plan.$0
6919383-FS2022-10-18Fire protection811 STEWART STArcher Construction is to provide the relocation of existing and/or addition of new sprinkler heads to accommodate the new ceiling and wall installations as shown on provided plans$0

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Seattle permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →