COMPANY RECORD · PHILADELPHIA, PA
S A Comunale Co Inc — permit history in Philadelphia, PA
S A Comunale Co Inc appears on 64 Philadelphia permit records from 2021 through 2026, all of them fire suppression.
Permit categories
| Category | Permits | Share |
|---|---|---|
| Fire Suppression | 64 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2021 | 18 |
| 2022 | 5 |
| 2023 | 13 |
| 2024 | 12 |
| 2025 | 10 |
| 2026 | 6 |
Busiest year on record: 2021, with 18 permits. One project can account for several filings, so read this as filing activity rather than workload.
PROJECTS AHEAD SEARCH
Search every Philadelphia permit, not only this company's
This page is a snapshot of S A Comunale Co Inc. The search behind it holds more than 242,223 Philadelphia permits naming a contractor, since 2021: 82,008 plumbing permits, 51,127 electrical permits, 25,710 mechanical permits, 25,367 residential building permits, 24,512 zoning permits.
- Search the full history by company, address, permit type or date range.
- Set an alert and get an email when a new permit matches — the next permit S A Comunale Co Inc files, or any new fire suppression permit in Philadelphia. A new permit is an early signal of work to bid on, supply or finance.
- Export to CSV for your CRM or spreadsheet.
Free account: newest 7 days of records, 10 searches a day and 1 daily alert. Full history, CSV export and instant alerts on paid plans from $49 a month ($24.50 for the first 3 months). Compare plans
Names on the same project timelines
| Name in source | Linked permits | Last seen |
|---|---|---|
| Lf Driscoll Company LLC | 6 | 2025-11-19 |
| International Management Consultants, Inc. | 4 | 2024-11-14 |
| Blue Rock Construction Inc | 4 | 2026-01-14 |
| Bsi Construction LLC | 3 | 2025-08-04 |
| Alston Construction Company Inc | 3 | 2025-04-24 |
| Clayco, Inc. | 2 | 2025-03-18 |
| Arco Db Companies, Inc. | 1 | 2023-09-27 |
| Franjo Construction Corporation | 1 | 2023-03-17 |
| Gilbane Building Company | 1 | 2023-03-20 |
| Hunter Roberts Holdings LLC | 1 | 2022-03-08 |
| E K Multiservice LLC | 1 | 2023-02-06 |
| James M Rogers | 1 | 2023-06-05 |
19 named participants share a resolved project timeline with S A Comunale Co Inc. A shared timeline is a research lead, not proof of a partnership or a current contract. Names appear as the authority published them.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 1900 KITTY HAWK AVE | 2026-10-13 |
| 6310 W PASSYUNK AVE | 2026-10-13 |
| 3501 CIVIC CENTER BLVD | 2026-06-11 |
| 2301 N 29TH ST | 2026-01-14 |
| 5100 S 16TH ST | 2026-01-14 |
| 11301 E ROOSEVELT BLVD | 2025-08-04 |
| 1101 ARCH ST | 2025-04-30 |
| 14515 MCNULTY RD | 2025-04-24 |
| 3144 W PASSYUNK AVE | 2025-03-18 |
| 3060 S 61ST ST | 2024-12-12 |
| 15000 E ROOSEVELT BLVD | 2024-11-14 |
| 2100 BENJAMIN FRANKLIN PKWY | 2024-07-17 |
| 1201 NORMANDY PL | 2024-05-10 |
| 5000 RICHMOND ST | 2023-11-07 |
35 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Also named on permits at the same addresses
| Company | Shared addresses | Years |
|---|---|---|
| Klehr Harrison Harvey Branzburg LLP | 9 | 2021–2026 |
| Paramount Electrical | 6 | 2021–2025 |
| John J Dougherty & Son Inc | 6 | 2021–2024 |
| Terry Abrams | 6 | 2021–2026 |
| Bowe & Gant Electrical Services LLC | 5 | 2022–2026 |
| Stephanie Rumer | 5 | 2021–2026 |
| Tandem Associates Inc | 5 | 2023–2026 |
| Armour & Sons Electric Inc | 5 | 2021–2026 |
Companies that also appear in Philadelphia permit records at addresses where S A Comunale Co Inc filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.
Permits on record
64 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| FP-2026-001735 | 2026-10-13 | Fire Suppression | 1900 KITTY HAWK AVE | TO INSTALL NEW FIRE SUPPRESSION SYSTEM PROVIDED ON GROUND FLOOR BELOW CENTER MEZZANINE 1, ABOVE CENTER MEZZANINE 1 AND MEZZANINE 2, AND TO GROUND FLOOR BUSINESS OCCUPANCY (SEPARATE | |
| FP-2026-001717 | 2026-10-13 | Fire Suppression | 6310 W PASSYUNK AVE | FOR AN ALTERATION TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 TO ACCOMMODATE A PORTION OF AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" RP AMESS MAXIM 400 | |
| FP-2026-001755 | 2026-09-14 | Fire Suppression | 1900 KITTY HAWK AVE | FOR THE ALTERATION OF AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY & EXISTING FIRE PUMP. ALL WORK SHALL BE PERFORMED BY | |
| FP-2025-002261 | 2026-06-11 | Fire Suppression | 3501 CIVIC CENTER BLVD | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT FLOORS 10,11,21-27, AND STANDPIPES COMPLYING WITH NFPA 14 AS PER THE APPROVED PLANS. ALL WORK SHALL BE PERFORM | |
| FP-2025-002383 | 2026-01-14 | Fire Suppression | 2301 N 29TH ST | FOR THE PARTIAL DEMO OF 1" EXISTING BRANCH LINE AND THE INSTALLATION OF 1 1/4" BRANCH LINE AND 49 NEW PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA | |
| FP-2025-001350 | 2026-01-14 | Fire Suppression | 5100 S 16TH ST | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 4" MAIN FIRE SERVICE LINE WITH A 6-INCH AMES COLT 200 BACKFLOW PREVENTION ASSEMBLY, A | |
| FP-2025-000753 | 2025-11-19 | Fire Suppression | 3501 CIVIC CENTER BLVD | FOR THE INSTALLATION OF NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 TO AN EXISTING 8" SERVICE LINE TO INCLUDE TWO (2) 8" AMES COLT 200 BACKFLOW PREVENTION ASSEMBLY, TWO (2) | |
| FP-2025-002262 | 2025-11-17 | Fire Suppression | 3501 CIVIC CENTER BLVD | Rough-In Permit for FP-2025-002261 Core and shell protection only for Floors 1-29; Fire pumps located on A level on previous permit; full shell coverage on Floors 10,11,21-27 onl | |
| FP-2025-001528 | 2025-08-04 | Fire Suppression | 11301 E ROOSEVELT BLVD | FOR THE ALTERATION OF AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 WITH AN EXISTING BACKFLOW PREVENTION ASSEMBLY. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CO | |
| FP-2025-001004 | 2025-05-14 | Fire Suppression | 3501 CIVIC CENTER BLVD | Rough-In Permit for FP-2025-000753 Install fire sprinklers for Levels A&B including 2) fire pumps fed by 2) backflows from 2) 8" taps Tower to be submitted on in future Fire Spr | |
| FP-2025-000553 | 2025-04-30 | Fire Suppression | 1101 ARCH ST | FOR THE PIPE REPLACEMENT TO THE DOCK GENERATOR ROOM IN AN EXISTING STRUCTURE. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. | |
| FP-2025-000337 | 2025-04-24 | Fire Suppression | 14515 MCNULTY RD | FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" FIRE SERVICE LINE AND 10." RP WATTS BACK | |
| FP-2025-000555 | 2025-03-28 | Fire Suppression | 1101 ARCH ST | FOR THE RELOCATION OF SPRINKLER HEADS. **ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.** | |
| FP-2025-000302 | 2025-03-19 | Fire Suppression | 3501 CIVIC CENTER BLVD | FOR THE INSTALLATION OF TEMPORARY STANDPIPE AS PER APPROVED PLANS. *SEPARATE PERMITS REQUIRED FOR PERMANENT STANDPIPES.* | |
| FP-2025-000463 | 2025-03-18 | Fire Suppression | 3144 W PASSYUNK AVE | FOR THE INSTALLATION OF 27 NEW PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING. AS PER APPROVED PLANS. ALL WORK SHALL BE PE | |
| FP-2025-000066 | 2025-02-03 | Fire Suppression | 11301 E ROOSEVELT BLVD | FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 2" MAIN FIRE SERVICE LINE AND 10" DC AMESS 2 | |
| FP-2024-002301 | 2024-12-12 | Fire Suppression | 3060 S 61ST ST | FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 (ESFR) THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" FIRE SERVICE LINE AND 10." RP AM | |
| FP-2024-001122 | 2024-11-14 | Fire Suppression | 15000 E ROOSEVELT BLVD | INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 WITH A FIRE DEPARTMENT CONNECTION, BACKKFLOW PREVENTION DEVICE AND 10" SERVICE LINE, THROUGHOUT A ON | |
| FP-2024-002298 | 2024-11-08 | Fire Suppression | 15000 E ROOSEVELT BLVD | FOR THE INSTALLATION OF SPRINKLER HEADS TIED INTO EXISTING AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH EXISTING BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13. ALL | |
| FP-2024-002300 | 2024-10-30 | Fire Suppression | 15000 E ROOSEVELT BLVD | FOR THE INSTALLATION OF SPRINKLER HEADS TIED INTO EXISTING AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH EXISTING BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH NFPA 13. ALL | |
| FP-2024-001128 | 2024-10-28 | Fire Suppression | 15000 E ROOSEVELT BLVD | FOR THE INSTALLATION OF A 12-INCH FIRE SERVICE LINE, 12-INCH BACKFLOW PREVENTER, FIRE PUMP AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND N | |
| FP-2024-002215 | 2024-10-22 | Fire Suppression | 15000 E ROOSEVELT BLVD | Rough-In Permit for FP-2024-001122 Install Fire Pump and Fire Sprinkler System Through-out. | |
| FP-2024-002214 | 2024-10-22 | Fire Suppression | 15000 E ROOSEVELT BLVD | Rough-In Permit for FP-2024-001128 Provide Fire Pump & Fire Sprinkler System throughout. | |
| FP-2024-001222 | 2024-07-24 | Fire Suppression | 14515 MCNULTY RD | FOR THE INSTALLATION OF A 10-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY AND FIRE PUMP IN ACCORDANCE WITH NFPA 13 | |
| FP-2024-001475 | 2024-07-17 | Fire Suppression | 2100 BENJAMIN FRANKLIN PKWY | Rough-In Permit for FP-2024-001467 Add new backflow to new fire pump supplying new wet and dry systems utilizing 154 heads per NFPA 13 & 20 for compliant coverage of the new 2 st | |
| FP-2024-000723 | 2024-05-23 | Fire Suppression | 3144 W PASSYUNK AVE | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" FIRE SERVICE LINE AND 10." RP WATT/AMES MAXIM-M400 BACKFLO | |
| FP-2023-002967 | 2024-05-10 | Fire Suppression | 1201 NORMANDY PL | FOR ALTERATIONS TO AN EXISTING AUTOMATIC SPRINKLER SYSTEM AT THE 2ND FLOOR OF THE EXISTING BUILDING TO INCLUDE ADDITION AND RELOCATION OF SPRINKLER HEADS. ALL WORK TO BE DONE PER A | |
| FP-2024-000037 | 2024-01-12 | Fire Suppression | 1201 NORMANDY PL | Rough-In Permit for FP-2023-002967 Demo of existing piping as shown on FP-2 and rough-in of new piping as shown on FP-1 | |
| FP-2023-002435 | 2023-11-07 | Fire Suppression | 5000 RICHMOND ST | FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" FIRE SERVICE LINE AND 10." RP WATTS LF | |
| FP-2023-002438 | 2023-11-03 | Fire Suppression | 5000 RICHMOND ST | FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 10" FIRE SERVICE LINE AND 10." RP WATTS LF | |
| FP-2023-002164 | 2023-11-02 | Fire Suppression | 7101 MILNOR ST | FOR ALTERATIONS TO THE EXISTING FIRE SUPPRESSION SYSTEM TO ADD SPRINKLERS TO NEW OFFICE SPACE AND HOSE VALVES AS PER PLANS. | |
| FP-2023-002165 | 2023-10-19 | Fire Suppression | 6310 W PASSYUNK AVE | FOR THE INSTALLATION OF A 10-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY AT METER PIT AND FIRE PUMP IN ACCORDANCE | |
| FP-2023-002445 | 2023-10-19 | Fire Suppression | 7101 MILNOR ST | Rough-In Permit for FP-2023-002164 Add 77 sprinklers to new office tenant fit out in existing warehouse, under RTU in warehouse space and add (17) 1 1/2" hose valves in warehouse. | |
| FP-2023-001548 | 2023-09-27 | Fire Suppression | 5505 TACONY ST | ALTERATIONS/ADDITIONAS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING WITH EXISTING BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL W | |
| FP-2023-001192 | 2023-06-05 | Fire Suppression | 1425 LOCUST ST | EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and si | |
| FP-2023-000198 | 2023-05-01 | Fire Suppression | 1200 INTREPID AVE | INSTALLATION OF CLASS I MANUAL DRY STANDPIPES TO AN EXISTING OPEN PARKING GARAGE AS PER APPROVED PLAN AND NFPA 14. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICE | |
| FP-2022-003163 | 2023-03-27 | Fire Suppression | 1 DOCK ST | FOR THE ADDITION OF SPRINKLERS HEADS TO AN EXISTING SYSTEM TO ACCOMMODATE NEW LAYOUT APPROVED UNDER CP-2020-002762. WORK TO BE DONE AS PER APPROVED PLANS AND IN ACCORDANCE WITH NFP | |
| FP-2023-000319 | 2023-03-20 | Fire Suppression | 3317-33 CHESTNUT ST | FOR THE INSTALLATION OF A 6-INCH FIRE SERVICE LINE FOR AN AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM WITH A BACKFLOW PREVENTION ASSEMBLY, STANDPIPES, AND FIRE PUMP IN ACCORDANCE W | |
| FP-2022-000974 | 2023-03-17 | Fire Suppression | 1213-19 WALNUT ST | Fire Suppression System Permit for combo CP-2022-001093 | |
| FP-2023-000115 | 2023-02-15 | Fire Suppression | 241-43 CHESTNUT ST | FOR THE ALTERATIONS TO THE EXISTING FIRE SUPPRESSION SYSTEM FOR TENENAT FIT-OUT AS PER PLANS. | |
| FP-2023-000112 | 2023-02-06 | Fire Suppression | 241-43 CHESTNUT ST | FOR THE EXTENSION OF AN EXISTING NFPA 13 FIRE SUPPRESSION SYSTEM SERVICED BY A TWO INCH FIRE SERVICE LINE WITH A BACKFLOW PREVENTER ASSEMBLY AND EXISING FIRE PUMP. ALL WORK TO BE D | |
| FP-2022-002323 | 2022-11-15 | Fire Suppression | 7101 MILNOR ST | FOR THE INSTALLATION OF SEVEN (7) AUTOMATIC WET SPRINKLER SYSTEMS THROUGHOUT A ONE (1) STORY WAREHOUSE STRUCTURE TO BE SERVED BY ONE (1) NEW EIGHT (8) INCH FIRE SERVICE LINE AND A | |
| FP-2022-002425 | 2022-11-15 | Fire Suppression | 1201 NORMANDY PL | Rough-In Permit for FP-2022-002262 Provide new wet systems and standpipes for new 4 story mid-rise office building with fire pump & roof partial mechanical floor; core and shell pr | |
| FP-2022-002262 | 2022-11-15 | Fire Suppression | 1201 NORMANDY PL | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 6" MAIN FIRE SERVICE LINE WITH A 6" AMES 200 BACKFLOW PREVENTION ASSEMBLY AND TWO (2) | |
| FP-2022-000590 | 2022-03-08 | Fire Suppression | 460-74 N 2ND ST | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 FOR A SPACE ON THE SECOND FLOOR OF AN EXISTING STRUCTURE. INSTALLATION TO BE LINKED TO AN EXISTING SYSTEM AS PER APPROVE | |
| FP-2022-000700 | 2022-03-04 | Fire Suppression | 460-74 N 2ND ST | Rough-In Permit for FP-2022-000590 Providing Sprinkler Protection to the Second Floor of the Building. | |
| FP-2021-002904 | 2021-12-30 | Fire Suppression | 2500 LEAGUE ISLAND BLVD | FOR THE INSTALLATION OF A 10-INCH FIRE SERVICE LINE, 10-INCH BACKFLOW PREVENTER, FIRE PUMP AND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND N | |
| FP-2021-002825 | 2021-12-02 | Fire Suppression | 6901 ELMWOOD AVE | FOR THE INSTALLATION OF A FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 STANDARDS. SYSTEM TO BE INSTALLED BY AN APPROVED TECHNICIAN. | |
| FP-2021-002903 | 2021-12-02 | Fire Suppression | 1101-53 CHESTNUT ST | INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT A PORTION OF AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 8" MAIN FIRE SERVICE LINE AND 8." DC FEBCO BACKFL | |
| FP-2021-002826 | 2021-11-09 | Fire Suppression | 1800 ARCH ST | EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and si |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Philadelphia permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →
Is this your company? Show this public permit record on your website with a free badge.