COMPANY RECORD · PHILADELPHIA, PA

Jonathan Kozak — permit history in Philadelphia, PA

Jonathan Kozak appears on 40 Philadelphia permit records from 2022 through 2026, all of them electrical.

Permit categories

CategoryPermitsShare
Electrical40100%

Activity by year

YearPermits issued
202216
20237
20245
20258
20264

Busiest year on record: 2022, with 16 permits. One project can account for several filings, so read this as filing activity rather than workload.

Names on the same project timelines

Name in sourceLinked permitsLast seen
Aimes LLC322026-07-20
Rider Homes32026-03-05
David Thompson12025-06-03
Mdl Restoration Inc12024-01-02
Velar Stone LLC12026-06-20

5 named participants share a resolved project timeline with Jonathan Kozak. A shared timeline is a research lead, not proof of a partnership or a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
3632-34 GERMANTOWN AVE2026-07-20
2511 N JESSUP ST2026-06-20
6015 CHESTNUT ST2026-04-29
2524 LOMBARD ST2026-03-05
5114 WAYNE AVE2025-10-16
2011 EASTBURN AVE2025-10-01
4913 N BROAD ST2025-08-04
1215 WHARTON ST2025-07-24
1830 CATHARINE ST2025-06-03
1021 ANNIN ST2025-02-26
5644 ANGORA TER2025-01-02
5716 OSAGE AVE2024-10-22
5319 ANGORA TER2024-01-24
5320 ANGORA TER2024-01-24

37 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Also named on permits at the same addresses

CompanyShared addressesYears
Big Dawg's Plumbing & Heating Inc302021–2026
Aimes LLC302021–2026
B M Consulting Services Inc152021–2025
Designblendz Architecture LLP132021–2025
Harring Fire Protection, LLC92022–2023
Rider Homes32025–2026
Permit Philly LLC22021–2025
Arrick J Wise12026

Companies that also appear in Philadelphia permit records at addresses where Jonathan Kozak filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.

Permits on record

40 permits; open the full list
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
EP-2026-0048842026-07-20Electrical3632-34 GERMANTOWN AVEElectrical fit-out of commercial space, including the Fire alarm, all work per approved plans NEC 2017 NFPA2016
EP-2026-0049842026-06-20Electrical2511 N JESSUP STReplace 100 amp panel (existing), Wire throughout, install all switches, outlets, lighting fixtures as per code. Install smoke detectors throughout as per 2017 NEC.
EP-2026-0022462026-04-29Electrical6015 CHESTNUT STInstall 200 amp service, rewire all bedrooms, bathrooms, kitchen, living room throughout as per NEC code. Install smoke detectors throughout as per code.
EP-2026-0015792026-03-05Electrical2524 LOMBARD STWire kitchen throughout to Current NEC codes/requirements.
EP-2025-0090872025-10-16Electrical5114 WAYNE AVEInstall two 200 amp panel replacements, Install replacement lights throughout, install replacement outlets throughout as per NEC codes.
EP-2024-0087842025-10-01Electrical2011 EASTBURN AVEInstall 1200 amp service as per prints, wire all units to code, all kitchens, living rooms, dining rooms, bedrooms and bathrooms, install smoke/carbon alarms ,fire alarms , rescue
EP-2025-0065592025-10-01Electrical3632-34 GERMANTOWN AVEINSTALL 380 AMP ELECTRICAL SERVICE AND 15 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 125 AMP SUBPANEL FOR HOUSE, ONE 200 AMP SUBPANEL FOR THE COMMERCIAL SPACE AND
EP-2025-0047882025-08-04Electrical4913 N BROAD STINSTALL LIGHT FIXTURES AND LIGHTING CONTROLS. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC AND PER PLANS.
EP-2025-0065572025-07-24Electrical1215 WHARTON STReplace and upgrade existing electrical panel and circuits/devices as per code. 100 Amp service panel change.
EP-2025-0039612025-06-03Electrical1830 CATHARINE STExisting service to remain, wire throughout as per NEC code, install all switches, outlets and recess lighting throughout as per code.
EP-2025-0012822025-02-26Electrical1021 ANNIN STKitchen rewire, install 6 recess lights throughout.
EP-2021-0127662025-01-02Electrical5644 ANGORA TERElectrical Permit for combo RP-2021-012917
EP-2021-0152692024-10-22Electrical5716 OSAGE AVEElectrical Permit for combo RP-2021-019527
EP-2023-0122582024-01-24Electrical5319 ANGORA TERINSTALL A 300 AMP SERVICE, (4) GANG METER BANK, (3) 150 AMP PANELS & FEEDERS, (1) 100 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS & THREE DWELLING UNITS. INSTALL
EP-2024-0000142024-01-24Electrical5320 ANGORA TERInstall 400 amp service and grounding, (1) 100 amp house panel, and (3) 150 amp unit panels. Wire throughout. Install receptacles, lighting, telecommunications wiring, smoke/CO al
EP-2023-0088102024-01-02Electrical893 BELMONT AVEInstall 800 amp service , wire all bedrooms, kitchens, living rooms, bathrooms, basements, smoke alarms ,vacant commercial. .Install fire alarm . ALL WORK IS TO BE DONE ACCORDING T
EP-2023-0092252024-01-02Electrical3712 BARING STInstall 100 amp service , wire all receptacles, switches, lighting throughout (bedrooms, kitchen, living room, bathrooms) Install all smoke and carbon detectors throughout as per N
EP-2023-0087662023-10-06Electrical893 BELMONT AVEInstall temporary 100amp service for construction. AS PER NEC 2017
EP-2023-0061742023-07-07Electrical2733 N FRONT STInstall 100amp service (temp) as per 2017 nec
EP-2023-0029212023-04-04Electrical846 N 44TH STInstall outlets, switches, hood wiring, and exit signs, as per prints in the kitchen as per 2017 nec
EP-2023-0004672023-03-31Electrical2209 W VENANGO STINSTALL A 800 AMP 120/240 1 PHASE SERVICE, (13) GANG METER BANK, (12) 125 AMP PANELS & FEEDERS, (1) 100 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS & 12 DWELLING
EP-2023-0009892023-03-30Electrical2733 N FRONT STInstall 1200 amp service. Wire all bedrooms, bathrooms, living rooms, kitchens throughout as per print. Install smoke alarms throughout as per 2017 NEC. Install fire alarm throu
EP-2022-0027472023-01-30Electrical1931 COLONIAL STElectrical Permit for combo RP-2022-000242
EP-2022-0024402023-01-30Electrical1537 E PASTORIUS STElectrical Permit for combo RP-2022-001177
EP-2022-0079602022-10-25Electrical6600 LANSDOWNE AVEInstall 600 amp service as per plans, wire all bedrooms, bathrooms, kitchen, living room and basement as per 2017 NEC codes. Install all smoke and carbon detectors throughout, inst
EP-2022-0079652022-10-25Electrical6606 LANSDOWNE AVEInstall 400 amp service as per prints. Wire throughout all bedrooms, bathrooms, living room, kitchen, basement, install smoke and carbon detectors as per 2017 NEC codes, install fi
EP-2022-0079632022-10-10Electrical6602 LANSDOWNE AVEInstall 400 amp electrical service with meter sockets and circuit breaker subpanels. Wire building throughout including all bedrooms, bathrooms, living room, kitchen , basement.
EP-2022-0079642022-10-10Electrical6604 LANSDOWNE AVEInstall 400 amp electrical service with meter sockets and circuit breaker panels. Wire throughout all bedrooms, bathrooms, living room, kitchen, basement, install smoke and carbo
EP-2022-0074622022-09-15Electrical5633 WARRINGTON AVEInstall 100 amp service. Wire all bedrooms, bathrooms, living room, kitchen, and basement as per code. Install smoke and carbon detectors as per NEC 2014 codes.
EP-2022-0074602022-09-15Electrical5629 WARRINGTON AVEInstall 100 amp service , Wire all bedrooms, bathrooms, living room, kitchen, and basement as per code. Install all smoke and carbon detectors as per NEC 2014 codes.
EP-2022-0038732022-07-08Electrical1804 W TIOGA STInstall 400 amp service, wire all bedrooms, bathrooms, living rooms, kitchens, and all smoke detectors as per 2017 NEC code. Install fire alarm as per 2017 NEC code and NFPA 72.
EP-2022-0038722022-07-08Electrical1802 W TIOGA STInstall 400 amp service- Wire all bedrooms, living rooms, kitchens, bathrooms, and all smoke detectors as per 2017 NEC code. Install fire alarm per 2017 NEC code and NFPA 72
EP-2022-0033262022-05-11Electrical5617 SANSOM STINSTALL A 300 AMP SERVICE, (4) GANG METER BANK, (3) 125 AMP PANELS & FEEDERS, (1) 100 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS AND THREE DWELLING UNITS. INST
EP-2022-0038712022-05-11Electrical1800 W TIOGA STInstall 400 amp service, wire all throughout bedrooms, kitchen, bathrooms, living rooms, wire all smoke alarms per 2017 NEC. Install fire alarm per 2016 NFPA 72.
EP-2022-0024362022-05-11Electrical111 N 63RD STInstall 600 amp service , wire all bedrooms, kitchens, bathrooms, living rooms, basement and 110v interconnected smoke alarms . Install fire alarm system wih low frequency sound in
EP-2022-0023232022-05-10Electrical109 N 63RD STINSTALL A 600 AMP SERVICE, (7) GANG METER BANK, (2) 150 AMP PANELS & FEEDERS, (4) 125 AMP PANELS & FEEDERS, (1) 60 AMP PANEL & FEEDER. INSTALL WIRING THROUGHOUT THE COMMON AREAS A
EP-2022-0003152022-05-10Electrical6641 LANSDOWNE AVEInstall 400amp service as per code and print Wire all11ov interconnected smoke alarms and carbon monoxide as per Code and prints. Install addressable fire alarm throughout w/ low f
EP-2022-0003212022-03-28Electrical1454 N 57TH STInstall 400 amp service as per 2017 NEC and print. Wire all smoke detectors and carbon monoxide as per code and prints Install electrical wiring switches and outlets in all bedroom
EP-2022-0003192022-03-17Electrical1432 N 57TH STINSTALL A 400 AMP SERVICE, (4) GANG METER BANK, (3) 125 AMP PANELS & FEEDERS, (1) 100 AMP PANEL & FEDER. PROVIDE WIRING THROUGHOUT THE COMMON AREAS AND THREE DWELLING UNITS. INSTAL
EP-2021-0121972022-01-11Electrical883 BELMONT AVEInstall 300 amp service , Install switches, outlets, smoked detectors as per print as per 2017 NEC. Install fire alarm , wire throughout as per 2016 NFPA 72.

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Search these records

The 40 permits above are a static record through 2026. Select a year above to open that year’s records, or search Jonathan Kozak in Philadelphia, PA by address, trade or date range.

Source and limits

Public Philadelphia permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →

Is this your company? Show this public permit record on your website with a free badge.