COMPANY RECORD · PHILADELPHIA, PA

Champion Electrical Solutions LLC — permit history in Philadelphia, PA

Champion Electrical Solutions LLC appears on 15 Philadelphia permit records from 2023 through 2026, most often electrical (80% of the record).

Permit categories

CategoryPermitsShare
Electrical1280%
Residential Building320%

2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.

Activity by year

YearPermits issued
20233
20245
20251
20266

Busiest year on record: 2026, with 6 permits. One project can account for several filings, so read this as filing activity rather than workload.

PROJECTS AHEAD SEARCH

Search every Philadelphia permit, not only this company's

This page is a snapshot of Champion Electrical Solutions LLC. The search behind it holds more than 242,223 Philadelphia permits naming a contractor, since 2021: 82,008 plumbing permits, 51,127 electrical permits, 25,710 mechanical permits, 25,367 residential building permits, 24,512 zoning permits.

  • Search the full history by company, address, permit type or date range.
  • Set an alert and get an email when a new permit matches — the next permit Champion Electrical Solutions LLC files, or any new electrical permit in Philadelphia. A new permit is an early signal of work to bid on, supply or finance.
  • Export to CSV for your CRM or spreadsheet.

Free account: newest 7 days of records, 10 searches a day and 1 daily alert. Full history, CSV export and instant alerts on paid plans from $49 a month ($24.50 for the first 3 months). Compare plans

Names on the same project timelines

Name in sourceLinked permitsLast seen
Ingrams Drain & Sewer Inc12024-03-13
Ll Mechanical Services, LLC.12024-12-20
Schweizer Fire Protection(Paul E Schweizer)12025-03-14
We Fix It LLC12024-03-26

4 named participants share a resolved project timeline with Champion Electrical Solutions LLC. A shared timeline is a research lead, not proof of a partnership or a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
1126-36 ARCH ST2026-10-20
1640 S 54TH ST2026-10-20
2016 FRANKFORD AVE2026-07-17
806 LINDENHURST ST2025-05-30
6321 CARDIFF ST2024-11-12
2334-36 E DAUPHIN ST2024-06-06
2517 N 31ST ST2023-12-28
3848-56 LANCASTER AVE2023-02-23
3902 N 7TH ST2023-01-13

9 distinct addresses on record. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Also named on permits at the same addresses

CompanyShared addressesYears
Barrymore Richards12026
Permit Philly LLC12026
Ll Mechanical Services, LLC.12024–2025
Schweizer Fire Protection(Paul E Schweizer)12024–2025
Lawrence Caro12024
Gregory Sanders12024–2025
Hormigon LLC12024
Dr Builders 35 LLC12023–2026

Companies that also appear in Philadelphia permit records at addresses where Champion Electrical Solutions LLC filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.

Permits on record

15 permits; open the full list
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
EP-2026-0097932026-10-20Electrical1126-36 ARCH STNew 20 amp receptacles 8, New switch & Track lights, new circuit for electrical stove.All commercial wiring (MC)
RP-2026-0111172026-10-20Residential Building1640 S 54TH STFOR THE STRUCTURAL REPAIR TO EXTERIOR PORCH, WALL, JOISTS AND ROOF TO RESOLVE CASE #CF-2026-047869. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIF
EP-2026-0047462026-09-08Electrical1126-36 ARCH STElectrical Permit for combo CP-2026-002785
EP-2026-0024942026-07-17Electrical2016 FRANKFORD AVEElectrical Permit for combo CP-2026-000878
EP-2026-0042412026-05-22Electrical1126-36 ARCH STAdding new 20 amp switch w 8 recessed lights in 12/2 MC wire 20 amp & 6-20 amp outlets 4 new 20 amp circuits 2 existing outlets will get A new 20 amp devices & new metal plate all
EP-2025-0123032026-01-06Electrical1126-36 ARCH STAdd 4 20 amp receptacles, add 3 lights
EP-2025-0033252025-05-30Electrical806 LINDENHURST ST"NEW FIRE ALARM" system w horn strobes, smoke detectors, pull stations, annunciator & fire alarm control panel with monitoring.
EP-2024-0107102024-12-05Electrical806 LINDENHURST STElectrical Permit for combo RP-2024-005822
RP-2024-0058222024-11-14Residential Building806 LINDENHURST STInterior renovations only of an existing single family structure, details as shown on the plan. Permit amended on 3/14/25: relocating a bathroom an existing bathroom & relocating
EP-2024-0105982024-11-12Electrical6321 CARDIFF STAmended 12/6/24 200 amp service Complete 100 amp service Rewire thru out as per nec 2017 Smokes and CO 20 recess lights
EP-2024-0040652024-06-06Electrical2334-36 E DAUPHIN STFull rewire new lighting, switching, new 200 amp service w grounding & bonding & 40 pos main load center, new 200 amp service drop, new 200 amp meter socket, hard wired smoke detec
RP-2023-0137072024-02-14Residential Building2334-36 E DAUPHIN STKITCHEN RENOVATION INCLUDING NEW FIRST FLOOR BATHROOM
EP-2023-0123762023-12-28Electrical2517 N 31ST STNEW 200 AMP SERVICE-200 AMP SERVICE DROP W 3 GANG METER SOCKER, 3 SEPARATE DISCONNECTS (1 FOR EACH APT & ONE FOR THE COMMON AREA) 3 SEPARATE SUB PANELS & GROUNDING/BONDING AS PER N
EP-2023-0016812023-02-23Electrical3848-56 LANCASTER AVEnew bathroom location requires new 20 amp gfci & a dual exhaust fan w light controlled by a motion detector as per 2017 nec
EP-2023-0002742023-01-13Electrical3902 N 7TH STinstalling new 200 amp service w 200 amp service cable drop, new 200 amp meter socket, new 40 position 200 amp main load center & updated grounding & bonding as per 2017 nec

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Philadelphia permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →

Is this your company? Show this public permit record on your website with a free badge.