COMPANY RECORD · PHILADELPHIA, PA

Brian Monroe — permit history in Philadelphia, PA

Brian Monroe appears on 203 Philadelphia permit records from 2021 through 2026, all of them electrical.

How Brian Monroe compares in Philadelphia

In 2025, Brian Monroe filed 41 electrical permits in Philadelphia — 52nd of 610 companies named on electrical permits that year. Across all records since 2021, it ranks 53rd of 1,021 with 203 electrical permits.

Ranked by the number of permits in the company's main category, among every company named on such permits in Philadelphia records — not only those with a page here. Companies with equal counts share a place. Filing volume measures activity, not quality.

Permit categories

CategoryPermitsShare
Electrical203100%

Activity by year

YearPermits issued
202142
202234
202327
202431
202541
202628

Busiest year on record: 2021, with 42 permits. One project can account for several filings, so read this as filing activity rather than workload.

Names on the same project timelines

Name in sourceLinked permitsLast seen
Mark Lawson312026-09-21
Level Up Builders LLC122026-09-29
Abbes Charii72026-04-10
Karl Arjun72022-01-07
Juan R Vega62025-09-26
Michael D Link42021-12-23
Maurice Gonzalez42022-07-26
Dtrm Construction42026-01-28
Hector Gonzalez32023-12-08
Eric Dawkins32023-07-12
Abenezer Francis32025-05-20
Argo Development Group LLC32023-07-13

59 named participants share a resolved project timeline with Brian Monroe. A shared timeline is a research lead, not proof of a partnership or a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
5442 WOODLAND AVE2026-10-23
2408 N 32ND ST2026-09-30
3103 N 32ND ST2026-09-29
6336 GREENE ST2026-09-25
7437 BEVERLY RD2026-09-21
633 W MOYAMENSING AVE2026-08-18
6151 MARKET ST2026-08-05
7237 PITTVILLE AVE2026-07-24
2054 MCKEAN ST2026-07-24
3107 N 32ND ST2026-07-18
6620 WOODLAND AVE2026-07-10
3025 WELSH RD2026-07-01
4228 LANCASTER AVE2026-06-29
2111 GREEN ST2026-06-29

196 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Also named on permits at the same addresses

CompanyShared addressesYears
Shegda Construction Corp402021–2026
Mark Lawson312023–2026
Level Up Builders LLC122022–2026
David R Smith112022–2026
Marc K Daniels102021–2026
Gary Thompson82021–2026
Abbes Charii72024–2026
Coffelt Contracting72021–2025

Companies that also appear in Philadelphia permit records at addresses where Brian Monroe filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.

Permits on record

203 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
EP-2026-0090622026-10-23Electrical5442 WOODLAND AVEInstall temporary 100 amp service on lot for new building construction.
EP-2026-0089962026-09-30Electrical2408 N 32ND STResidential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE as per Residential Service Equipment EZ Standard. Replace 200 amp service cable,
EP-2026-0093962026-09-29Electrical3103 N 32ND STRewire all of the building and replace 200 amp service size. Service size not being increased
EP-2026-0091732026-09-25Electrical6336 GREENE STReplace 4 recess lights and replace 2 light fixtures with 2 ceiling fans in porch area.
EP-2026-0083582026-09-21Electrical7437 BEVERLY RDRewire all of building new devices and replace 100 amp service line (No increase ) complete with meter, panel grounding.
EP-2026-0072802026-08-18Electrical633 W MOYAMENSING AVEResidential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE as per Residential Service Equipment EZ Standard
EP-2026-0067542026-08-05Electrical6151 MARKET STInstall fire alarm system throughout as per 2016 NFPA 72.
EP-2026-0067932026-07-24Electrical7237 PITTVILLE AVEResidential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE INCLUDING AN EMERGENCY DISCONNECT as per Residential Service Equipment EZ Standard
EP-2026-0067902026-07-24Electrical2054 MCKEAN STRewire second floor, living room and foyer with new devices to remove old wiring.
EP-2026-0050512026-07-18Electrical3107 N 32ND STRewire all of building new devices and install 100 amp service to NEC 2017
EP-2026-0064032026-07-10Electrical6620 WOODLAND AVEElectrical Permit for combo CP-2026-001961
EP-2026-0030482026-07-01Electrical3025 WELSH RDAMEND 09-24-2026 Residential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 AMP TO 200 AMP as per Residential Service Equipment EZ S
EP-2026-0054352026-06-29Electrical4228 LANCASTER AVEReplace smoke detectors and batteries for fire alarm system. No wiring to be done.
EP-2026-0051992026-06-29Electrical2111 GREEN STInstall (3) 100 amp panels, lighting, receptacles, switches, smoke alarms, and provide power to equipment as per 2017 NEC. Install fire alarm as per 2016 NFPA 72.
EP-2026-0051962026-06-29Electrical826 WYNNEWOOD RDRewire throughout. Install 400 amp service with grounding, (5) 125 amp panels, (1) 100 amp house panel, lighting, receptacles, smoke/CO alarms, and provide power to equipment as p
EP-2026-0030402026-04-15Electrical7345 E WALNUT LNRewire all of building new devices and install new 100 amp service complete for NEC 2017
EP-2026-0030412026-04-10Electrical1827 S 57TH STRewire all of building new devices and install new 100 amp service complete to NEC 2017
EP-2026-0023732026-04-08Electrical3826 GERMANTOWN AVEInstall 8 recess lights throughout unit 2 bathroom, living room and hallway and change out all receptacles.
EP-2026-0023782026-04-08Electrical622 E WYOMING AVEInstall a new 400-amp electrical service with five (5) meter packs, including service conductors, meter sockets, main disconnecting means, and proper grounding and bonding. Install
EP-2026-0023762026-03-25Electrical5422 WHITBY AVERewire all of building new devices and install 100 amp service complete
EP-2026-0014152026-03-25Electrical3831 N 19TH STAmend permit 4/7/2026 - Reduction of work to be limited to porch area Rewire all of building new devices complete. Existing 100 amp service to remain. All wiring to be done by fis
EP-2026-0010622026-02-10Electrical2371 78TH AVERewire all of building new devices and install new 100 amp service complete.
EP-2026-0007592026-02-07Electrical2401 RIDGE AVEReplace smoke detectors, horn/strobes, pull stations and emergency lighting. Replacement of devices only. No fire alarm panel or wiring to be done.
EP-2026-0006022026-01-28Electrical5857 HOFFMAN AVERewire a of second floor new devices & replace 100 amp panel.
EP-2026-0005352026-01-28Electrical6058 WEBSTER STRewire all of building new devices and install new 100 amp service complete.
EP-2026-0007362026-01-28Electrical1670 N FELTON STRewire all of building devices and install new 100 amp service.
EP-2026-0005632026-01-28Electrical1222 S EDGEWOOD STRewire all of second floor new devices
EP-2026-0002222026-01-13Electrical2404 GOLF RDAMEND 03/25/2026 Install 200 amp service Rewire all of building new devices and install new 100 amp service complete.
EP-2025-0117792025-12-23Electrical1355 E SEDGLEY AVERewire all of buildings new devices and install new 200 amp service
EP-2025-0120502025-12-22Electrical2700 N FAIRHILL STPlace 200 amp cable, panel, meter, service cable and grounding complete. Service work only. One on one replacement. No other wiring to be done.
EP-2025-0114972025-12-08Electrical1001 E LUZERNE STRewire all of building new devices and install new 200 amp service complete
EP-2025-0110752025-12-05Electrical5766 JEFFERSON STRewire all of building new devices and install new 200 amp service
EP-2025-0108312025-11-26Electrical2421 S 7TH STINSTALL 200 AMP ELECTRICAL SERVICE, METER SOCKET AND CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. INSTALL 7 BASEBOARD HEATERS. ALL WORK TO BE DONE ACCORDING TO THE 20
EP-2025-0106162025-11-17Electrical5356 MORRIS STRewire all of building néw devices and install 200amp service complete. Fishing all wires
EP-2025-0108212025-11-13Electrical2419 S 7TH STInstall 200 amp service complete & install 7 baseboard heaters. Fishing all lines.
EP-2025-0107742025-11-12Electrical6123 DELANCEY STRetire all of 2 apartments new devices and install new 200 amp service with 100 amp sub feeder panels.
EP-2025-0100532025-11-05Electrical7246 FORREST AVERewire all of building new devices and install new 100 amp service complete for 2017 electrical code.
EP-2025-0100222025-10-16Electrical5942 CHRISTIAN STRewire all of building new devices and install new 200 amp service complete
EP-2025-0097522025-10-09Electrical1018 S 55TH STReplace 200 amp 3 gang meter socket and install proper grounding throughout.
EP-2025-0091372025-09-29Electrical545 W LEHIGH AVEReplace Existing 200amp 3 gang motor socket. No other work to be done.
EP-2025-0089172025-09-26Electrical2129 N 2ND STRewire all of building two unit apartments new devices and install a 200 amp service with two 100 amp subpanels for apartments.
EP-2025-0089152025-09-17Electrical1319 PATRICK HENRY PLNew devices and install 100 amp service complete
EP-2025-0089132025-09-17Electrical347 MONTANA STRewire all of building new devices and install 200 amp service complete
EP-2025-0089162025-09-17Electrical2040 S 68TH STRewire all of building new devices and install 100 amp service complete
EP-2025-0071712025-09-17Electrical871 N LAWRENCE STRewire all of unit B building new devices and install up to 200 amp service complete.
EP-2025-0089142025-09-17Electrical757 S 51ST STNew devices and install 200 amp service complete
EP-2025-0056122025-08-13Electrical1807 N 33RD STINSTALL 400 AMP ELECTRICAL SERVICE AND 4 METER PACKS WITH PROPER GROUNDING AND BONDING. INSTALL ONE 100 AMP SUBPANELS FOR HOUSE AND ONE 125 AMP SUBPANEL FOR EACH OF THE 3 DWELLIN
EP-2025-0073022025-08-08Electrical2424 77TH AVERewire all of building new devices and install a 200 amp service complete.
EP-2025-0073342025-08-08Electrical1244 N ALLISON STRewire all of building new devices and install 100 amp service complete
EP-2025-0035002025-07-21Electrical4252-66 WHITAKER AVEInstall 800 amp service complete as on drawings. Service work only. No interior wiring to be done. -2017 NEC.

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Search these records

The 203 permits above are a static record through 2026. Select a year above to open that year’s records, or search Brian Monroe in Philadelphia, PA by address, trade or date range.

Source and limits

Public Philadelphia permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →

Is this your company? Show this public permit record on your website with a free badge.