COMPANY RECORD · PHILADELPHIA, PA
Amptron LLC — permit history in Philadelphia, PA
Amptron LLC appears on 265 Philadelphia permit records from 2021 through 2026, most often electrical (71.7% of the record).
Permit categories
| Category | Permits | Share |
|---|---|---|
| Electrical | 190 | 71.7% |
| Mechanical | 42 | 15.8% |
| Residential Building | 27 | 10.2% |
| Building | 6 | 2.3% |
4 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.
Activity by year
| Year | Permits issued |
|---|---|
| 2021 | 54 |
| 2022 | 51 |
| 2023 | 60 |
| 2024 | 44 |
| 2025 | 17 |
| 2026 | 39 |
Busiest year on record: 2023, with 60 permits. One project can account for several filings, so read this as filing activity rather than workload.
PROJECTS AHEAD SEARCH
Search every Philadelphia permit, not only this company's
This page is a snapshot of Amptron LLC. The search behind it holds more than 242,223 Philadelphia permits naming a contractor, since 2021: 82,008 plumbing permits, 51,127 electrical permits, 25,710 mechanical permits, 25,367 residential building permits, 24,512 zoning permits.
- Search the full history by company, address, permit type or date range.
- Set an alert and get an email when a new permit matches — the next permit Amptron LLC files, or any new electrical permit in Philadelphia. A new permit is an early signal of work to bid on, supply or finance.
- Export to CSV for your CRM or spreadsheet.
Free account: newest 7 days of records, 10 searches a day and 1 daily alert. Full history, CSV export and instant alerts on paid plans from $49 a month ($24.50 for the first 3 months). Compare plans
Names on the same project timelines
| Name in source | Linked permits | Last seen |
|---|---|---|
| Morelos Construction Inc | 7 | 2023-09-25 |
| Sturdy Builders Inc | 6 | 2024-09-30 |
| Richard Nelson | 6 | 2025-05-12 |
| Integrity Restore & Rehab | 5 | 2024-04-25 |
| Tri County HVAC And Contracting LLC | 5 | 2026-06-22 |
| Rigorous Contracting | 5 | 2026-04-17 |
| Alibey Management, Inc | 4 | 2026-03-30 |
| Broad Infinity LLC. | 4 | 2025-01-06 |
| Oliveiras Services LLC | 3 | 2026-01-07 |
| David Chekemian | 3 | 2024-04-10 |
| Arnez & Rhonda Kinard | 3 | 2023-10-12 |
| Emory Street Construction LLC | 2 | 2022-08-23 |
53 named participants share a resolved project timeline with Amptron LLC. A shared timeline is a research lead, not proof of a partnership or a current contract. Names appear as the authority published them.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 1609 W MENTOR ST | 2026-10-26 |
| 4951 MONUMENT RD | 2026-10-23 |
| 2419 MASTER ST | 2026-10-21 |
| 3042 N SWANSON ST | 2026-10-07 |
| 2743 S BEULAH ST | 2026-10-06 |
| 3601 RICHMOND ST | 2026-10-05 |
| 2034 WATKINS ST | 2026-10-01 |
| 856 E THOMPSON ST | 2026-09-30 |
| 4606 MILLETT ST | 2026-08-14 |
| 1429 W OLNEY AVE | 2026-08-07 |
| 2733 N 13TH ST | 2026-07-21 |
| 4604 WEYMOUTH ST | 2026-06-22 |
| 1442 W LOUDON ST | 2026-06-03 |
| 6371 EDMUND ST | 2026-05-14 |
202 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Also named on permits at the same addresses
| Company | Shared addresses | Years |
|---|---|---|
| Just Plumbing & Heating Inc | 35 | 2022–2025 |
| Herbert Hawkins | 13 | 2021–2026 |
| Sturdy Builders Inc | 11 | 2021–2026 |
| Thomas Uhl | 9 | 2022–2026 |
| Honest Plumbing & Heating LLC | 7 | 2025–2026 |
| Richard Nelson | 7 | 2021–2025 |
| Integrity Restore & Rehab | 7 | 2021–2024 |
| Burnsies Plumbing LLC | 6 | 2021–2026 |
Companies that also appear in Philadelphia permit records at addresses where Amptron LLC filed, in any year. Sharing an address is a documented co-appearance, not proof that they worked on the same project or with each other.
Permits on record
265 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| EP-2026-010179 | 2026-10-26 | Electrical | 1609 W MENTOR ST | INSTALL 200 AMP ELECTRICAL SERVICE AND THE MAIN CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT. INSTALL LIGHTING, SWITCHES AND RECEPTACLES OUT | |
| EP-2026-010233 | 2026-10-23 | Electrical | 4951 MONUMENT RD | Residential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 TO 200 INCLUDING AN EMERGENCY DISCONNECT as per attached Residential Serv | |
| EP-2026-009232 | 2026-10-21 | Electrical | 2419 MASTER ST | Replace a bad 4 gang meter socket with new 4 gang meter sock the old meter socket was the same as the one I’m replacing no service just socket | |
| EP-2026-008941 | 2026-10-07 | Electrical | 3042 N SWANSON ST | Install a 100-amp electrical service with a 30-space electrical panel. Install GFCI receptacle(s) and provide a dedicated circuit as required. First floor: Install dining room ligh | |
| EP-2026-009110 | 2026-10-06 | Electrical | 2743 S BEULAH ST | Residential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE as per Residential Service Equipment EZ Standard. Install a 100 amp service with | |
| CP-2026-003882 | 2026-10-05 | Building | 3601 RICHMOND ST | FOR EXTERIOR ALTERATIONS (NEW STEPS AND RAMP) AND LEVEL II INTERIOR ALTERATIONS. FOR USE AS A VACANT COMMERCIAL SPACE AT THE 1ST FLOOR (SEPARATE PERMITS REQUIRED FOR FIT-OUT AND IS | |
| EP-2026-009078 | 2026-10-01 | Electrical | 2034 WATKINS ST | Residential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE as per Residential Service Equipment EZ Standard. Rewire all outlets, switches, | |
| EP-2026-009122 | 2026-09-30 | Electrical | 856 E THOMPSON ST | Residential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 AMP TO 200 AMP as per Residential Service Equipment EZ Standard Rewire | |
| EP-2026-007335 | 2026-09-17 | Electrical | 3042 N SWANSON ST | Residential Service Equipment not exceeding a rating of 200 amps WITH NO INCREASE IN SERVICE SIZE as per Residential Service Equipment EZ Standard Install 4 gfci's in kitchen with | |
| EP-2026-007631 | 2026-08-14 | Electrical | 4606 MILLETT ST | Residential Service Equipment not exceeding a rating of 200 amps WITH AN INCREASE IN SERVICE SIZE FROM 100 AMP TO 200 AMP as per Residential Service Equipment EZ Standard Rewire | |
| MP-2026-003380 | 2026-08-07 | Mechanical | 1429 W OLNEY AVE | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| EP-2026-005298 | 2026-08-07 | Electrical | 1429 W OLNEY AVE | Rewire house with 30 outlets, 10 GFCI's 15 switches, & 60 recess lights. Install 3 smoke detectors & 3 smoke/CO detectors. Install a 100 amp service with a 30 space pael with AFC | |
| RP-2026-006398 | 2026-07-22 | Residential Building | 1429 W OLNEY AVE | EZ PERMIT STANDARDS ALTERATIONS- For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and req | |
| MP-2026-003992 | 2026-07-21 | Mechanical | 2733 N 13TH ST | FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO B | |
| EP-2026-003315 | 2026-07-20 | Electrical | 2733 N 13TH ST | Install a new 300-amp electrical service with four (4) meter packs, including service conductors, meter sockets, main disconnecting means, and proper grounding and bonding. In | |
| RP-2026-001410 | 2026-07-10 | Residential Building | 856 E THOMPSON ST | FOR INTERIOR ALTERATIONS AND ROOF DECK ADDITION WITH ACCESS STRUCTURE ON AN EXISTING ATTACHED STRUCTURE USED AS A SINGLE-FAMILY DWELLING AS PER BUILDING APPLICATION/PLAN. | |
| MP-2026-003384 | 2026-07-09 | Mechanical | 2733 N 13TH ST | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| EP-2026-005732 | 2026-06-22 | Electrical | 4604 WEYMOUTH ST | Rewire all outlets, switches; install 40 recess lights; Install 3 - smoke/Co detectors, 6 total. Install 100 amp service with a 30 space panel with 16 AFCI breakers. Install 20 s | |
| EP-2026-002397 | 2026-06-03 | Electrical | 1442 W LOUDON ST | Rewire house by fishing, All outlets, lights, & GFCI's and hard wired smokes, switches. Install 100 or 200 amp service. | |
| EP-2026-002412 | 2026-05-14 | Electrical | 6371 EDMUND ST | Installation of 200 amp service, smoke detectors, carbon monoxide detectors all according to the attached contractual agreement. Electrical work by fishing. | |
| EP-2026-004006 | 2026-05-11 | Electrical | 6512 N 13TH ST | Install a 200 amp service 40 space panel with a 100 amp panel & disconnect | |
| EP-2026-003783 | 2026-05-06 | Electrical | 2261 RUFFNER ST | Rewire all outlets, switches. Install 30 recess lights, smoke detectors and a 100 amp service with a 90 space panel by fishing. | |
| EP-2026-003314 | 2026-04-21 | Electrical | 137 W WASHINGTON LN | Furnish and install a fire alarm system, including all required fire alarm control equipment, initiating devices, notification appliances, wiring, terminations, programming, and te | |
| EP-2025-007295 | 2026-04-17 | Electrical | 226 MANHEIM ST | New electrical wiring for a 3-unit 3-story building undergoing interior renovation. 400 amp service fire alarm installations in accordance with NFPA 2016&The Philadelphia Fire Code | |
| EP-2026-002897 | 2026-04-17 | Electrical | 1434 W VENANGO ST | Install 400 amp SERVICE, with a 4 gang meter socket,, with 60 amp house panel & 3-125 amp sub panels. Rewire building with outlets, switches, smoke alarms & recessed lights throug | |
| EP-2026-002898 | 2026-04-17 | Electrical | 2330 N 20TH ST | Install 200 amp service with meter socket & 40 space 200 amp panel. Rewire all outlets, switches, & lights throughout by fishing | |
| EP-2026-002405 | 2026-03-30 | Electrical | 3117 HOPE ST | Rewire Complete 2 Story property | |
| EP-2026-002172 | 2026-03-27 | Electrical | 4359 MITCHELL ST | Rewire house with 70 outlets, 20 light switches, 7 GFCI's, 7 smoke detectors, 200 AMP Service with 40 Space Panel, and 70 Recess lights (28 circuits total) | |
| EP-2026-002173 | 2026-03-27 | Electrical | 2823 PARRISH ST | Rewire house with outlets, switches, GFCI's, smoke detectors throughout with 30 recess lights. Install new 200 amp service with a 40 space panel. | |
| MP-2026-001471 | 2026-03-27 | Mechanical | 4359 MITCHELL ST | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| EP-2025-007303 | 2026-03-27 | Electrical | 222 MANHEIM ST | Install 200A service, wire throughout 3 family dwelling. emergency lighting, 110v interconnected smoke alarms. Install complete fire alarm system .ALL WORK IS TO BE DONE ACCORDING | |
| EP-2026-002604 | 2026-03-27 | Electrical | 6022 N MARVINE ST | Install 200 volt Service & Panel 30 space | |
| EP-2026-002407 | 2026-03-27 | Electrical | 6410 SPRAGUE ST | 100 Amp Service and Panel - 32 Space Panel, install smoke Detector, Install smoke carbon monoxide detector | |
| MP-2026-001472 | 2026-03-27 | Mechanical | 2823 PARRISH ST | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| EP-2025-012090 | 2026-02-08 | Electrical | 526 S 60TH ST | INSTALL 200 AMP ELECTRICAL SERVICE, METER SOCKET AND CIRCUIT BREAKER PANEL WITH PROPER GROUNDING AND BONDING. REWIRE HOUSE THROUGHOUT AND INSTALL LIGHTING, SWITCHES, EXIT SIGNS, | |
| EP-2026-000366 | 2026-01-30 | Electrical | 3916-22 LOCUST WALK | Install 20 amp GFCI circuit in bathroom; Install exhaust fan and light with switch; remove & install new light. Fishing | |
| EP-2025-007986 | 2026-01-07 | Electrical | 734 JEFFERSON ST | Install (3) 600kCMIL service& meterbank , Wire 3 - 2 bedrooms apartments and 3 - 1 bedroom apartments; Rewire all outlets, switches, and lights throughout all apartments and common | |
| MP-2025-005207 | 2026-01-07 | Mechanical | 734 JEFFERSON ST | FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE D | |
| RP-2025-011979 | 2026-01-02 | Residential Building | 2425 N 16TH ST | rear wall rebuild in kind, details as shown on plan. no other work included. | |
| MP-2025-004973 | 2025-12-19 | Mechanical | 526 S 60TH ST | FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE D | |
| RP-2025-006682 | 2025-12-11 | Residential Building | 2903 WILDER ST | FOR INTERIOR ALTERATIONS THROUGHOUT AN EXISTING ATTACHED STRUCTURE USED AS A SINGLE-FAMILY DWELLING AS PER BUILDING APPLICATION/PLAN. **BASEMENT STORAGE/UTILITY ONLY UNINHABITABLE | |
| EP-2025-009482 | 2025-10-07 | Electrical | 217 FARRAGUT ST | Rewire 2 apartments with 100 amp sub panels to each apartment. Rewire all outlets, switches, & lights. Install 20 recess lights in each apartment. Install house panel & house ci | |
| EP-2025-008590 | 2025-10-01 | Electrical | 2910 N TAYLOR ST | Rewire all outlets, switches, and lights throughout. Add hardwire smoke detector and smokes throughout. Install 100 amp service - 30 space panel | |
| MP-2025-005060 | 2025-10-01 | Mechanical | 217 FARRAGUT ST | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| MP-2025-004974 | 2025-10-01 | Mechanical | 2910 N TAYLOR ST | EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from the | |
| EP-2025-008016 | 2025-09-17 | Electrical | 218 W ABBOTTSFORD AVE | Rewire all outlets, switches, and lighting. Install 45 recessed lights. Install new 200A service with 200A, 40-space panel, 200A meter socket, and associated wiring. | |
| CP-2025-001824 | 2025-08-06 | Building | 2647 N 17TH ST | FOR LEVEL II INTERIOR ALTERATIONS WITH NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK. | |
| EP-2025-004791 | 2025-07-28 | Electrical | 5249 SPRUCE ST | Install wiring for 4 apartments with switches ,110v interconnected smoke alarms, outlets, lights throughout. Install 400 amp service with 4 meters; (4) 125 amp panels. Install fi | |
| RP-2025-002618 | 2025-06-22 | Residential Building | 2518 CORAL ST | INTERIOR RENOVATION AND FOR THE INCREASE TO THE HEIGHT OF AN EXISTING STRUCTURE. DETAILS AS SHOWN ON THE APPROVED PLAN. | |
| EP-2025-004128 | 2025-06-11 | Electrical | 912 WYNNEWOOD RD | Rewire all outlets, switches, & lights throughout with 200 amp service. |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Philadelphia permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →
Is this your company? Show this public permit record on your website with a free badge.