COMPANY RECORD · MINNEAPOLIS, MN

Lake Country Builders Ltd — permit history in Minneapolis, MN

Lake Country Builders Ltd appears on 57 Minneapolis permit records from 2016 through 2026, all of them general construction.

Permit categories

CategoryPermitsShare
General construction57100%

Activity by year

YearPermits issued
20161
20177
20185
201910
20209
20216
20227
20235
20244
20252
20261

Busiest year on record: 2019, with 10 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
41 4TH AVE N #1052026-03-27
2527 WASHBURN AVE S2025-07-02
448 MORGAN AVE S2025-05-15
2012 HUMBOLDT AVE S2024-07-01
3606 44TH ST W2024-05-14
1715 GRAND ST NE2024-03-07
1225 LASALLE AVE #23042024-02-22
518 RIVER ST2023-11-21
520 RIVER ST2023-08-10
602 RIVER ST2023-08-03
4615 WASHBURN AVE S2023-07-19
4621 EMERSON AVE S2023-03-22
3936 ZENITH AVE S2022-09-26
2219 PILLSBURY AVE #12022-08-03

50 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

57 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
BLDG11682232026-03-27General construction41 4TH AVE N #105REMODEL KITCHEN, SOME FRAMING 2020 MSBC
BLDG11249862025-07-02General construction2527 WASHBURN AVE SLOWER LEVEL BATHROOM UPDATE TO INCLUDE NEW TILES AND PLUMBING UPGRADES IN EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS) SEE APPROVED PLANS WITH WRITTEN SCOPE OF W
BLDG11174652025-05-15General construction448 MORGAN AVE SMAIN FLOOR UNIT KITCHEN REMODEL, CONVERSION OF POWDER ROOM TO 3/4 BATHROOM AND REMOVAL OF SOLAR PANELS ON ROOF OF EXISTING TWO-FAMILY DWELLINGS. AAJ (PROJECT DOX PLANS) DEMOLIT
BLDG10694072024-07-01General construction2012 HUMBOLDT AVE SRepairing rotted sheathing beneath stucco
BLDG10566092024-05-14General construction3606 44TH ST WNON-STRUTURAL BATHROOM REMODEL - DEMO EXISTING WC, SHOWER, AND LAV - INSTALL NEW WALK-IN SHOWER IN NEW LOCATION, WC IN NEW LOCATION, AND DOULBE LAV IN NEW LOCATION. INSTALL CEMENT
BLDG10461862024-03-07General construction1715 GRAND ST NE(DMH - ProjectDox) CONSTRUCT 10' X 6' TREATED WOOD DECK AT REAR SFD WITH GUARDRAIL, STAIRS, HANDRAIL, TREATED WOOD POSTS AND 2 FOOTING LOCATIONS. THE 2020 IRC HAS REQUIREMENTS A
BLDG10437702024-02-22General construction1225 LASALLE AVE #2304CONDO INTERIOR REMODEL (MAA)
BLDG10311972023-11-21General construction518 RIVER STNON-STRUCTURAL REMODEL AT EXISTING TOWNHOUSE DWELLING. BATHROOM REMODEL: DEMO EXISTING WC, LAV, TUB, AND SHOWER FIXTURES AND SELECT FRAMING TO INSTALL ENLARGED WALK-IN SHOWER AT T
BLDG10076342023-08-10General construction520 RIVER STreplace doors matching opening at back deck
BLDG10068882023-08-03General construction602 RIVER STINSTALL SCREEN PANELS AT COVERED DCK (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, P
BLDG10026392023-07-19General construction4615 WASHBURN AVE STWO STORY REAR ADDITION Structural engineer: B Clark #60507 Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED F
BLDG9829692023-03-22General construction4621 EMERSON AVE S(DMH-ProjectDox) DEMO EXISTING 3RD FLOOR TO FRAMING IN SFD AND REMODEL FOR OFFICE & BATHROOM. INSTALL NEW 22" CENTER RIDGE BEAM PER PLAN AND SIGNED ENGINEER LETTER FROM NORMAN
BLDG9634022022-09-26General construction3936 ZENITH AVE S(DMH-ProjectDox) REPAIRS TO EXISTING DECK TO SFD. INSTALL NEW CEDAR GUARDRAIL AND "ZURI" COMPOSITE DECKING. COMPOSITE DECKING BOARDS MUST BE LISTED AND LABLED AS MEETING A
BLDG9527972022-08-03General construction2219 PILLSBURY AVE #1INTERIOR REMODEL INCLUDING KITCHEN AND BATH The building inspector must approve the restoration of fire and acoustical assemblies disrupted by the work before concealment ce
BLDG9522682022-07-12General construction429 RIVER STREPLACE DECKING ONLY. NO STRUCTURAL WORK. (JJL)
BLDG9311682022-06-27General construction507 RIVER STstair additon off back deck DB apprvd 9/30/22 post-issue revisions adding the following note to dwgs: "The foot of stair may land on the proposed slab but the deck framing modif
BLDG9321772022-05-09General construction2012 HUMBOLDT AVE SLOWER LEVEL AND MAIN FLOOR REMODEL OF EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS). DEMOLITION WORK: - PARTIAL EXTERIOR AND INTERIOR DEMOLITION OF EXISTING BASEMENT
BLDG9397802022-04-29General construction1909 HUMBOLDT AVE SREPLACE EXTERIOR PATIO DOORS ANS SUBSEQUENT REPAIR WORK OF EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS). - REMOVE EXISTING PATIO DOORS ON LIVING ROOM EXTERIOR WALL, L
BLDG9249372022-02-18General construction1909 HUMBOLDT AVE S1300.0120 PERMITS, Subp. 4 Work exempt from permit. Exemptions from permit requirements of the code do not authorize work to be done in any manner in violation of the code or any o
BLDG9176102021-12-20General construction1715 GRAND ST NEREMODEL BASEMENT - RECONFIGURE & ADD BEDROOM ----- ----- Issuance of this permit doesn't allow a violation of Building Code or any other laws or ordinances. ----- 2020 Minn
BLDG9044852021-08-30General construction5141 XERXES AVE SEXISTING KITCHEN REMODELING. NEW SINK LOCATION AND REMOVE NON-BEARING WALL Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE
BLDG9024202021-08-16General construction433 RIVER STINTERIOR EXPANSION OF 2ND LEVEL MASTER SUITE INTO EXISTING FOYER SOUND/FIRE TEST ASSEMBLY__N.A. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONI
BLDG8922572021-07-07General construction523 RIVER STSTRUCTURAL REMODEL KITCHEN As noted on drawing, passing member reports must be provided at the framing inspection. certificate of occupancy required no special inspections requi
BLDG8689672021-02-18General construction1120 2ND ST Sinstall new doors and walls on first floor corridor system. ARCHITECT: OERTEL - Debra Brandwick #40651
BLDG8615142021-01-07General construction1627 WASHINGTON ST NE(DMH - ProjectDox) SELECT INTEROR DEMO OF APPROX. 1,100 SQ.FT SPACE AT MAIN FLOOR OF TWO STORY BUILIDNG AND REMODEL FOR NEW SINGLE USER ADA RESTROOMS, HALLWAY AND JANITOR CLOSET.
BLDG8458092020-09-10General construction407 RIVER STDECK ADDITION AND REDECK EXISTING SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED
BLDG8405032020-07-21General construction2818 ULYSSES ST NESFD KITCHEN REMODEL - DEMO NON-BEARING WALL & CLOSET ENCLOSING EXISTING KITCHEN AND DEMO PENINSULA, INSTALL NEW APPLICANCES/FIXTURES IN NEW LOCATIONS AND INSTALL NEW CENTER ISLAND.
BLDG8330592020-07-21General construction604 RIVER STBUILD SCREEN ENCLOSURE OVER EXISTING DECK (MAA) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQU
BLDG8402392020-07-17General construction100 3RD AVE S #2806INSTALL FLOORING AND PAINTING , NO CONSTRUCTION WORK AT UNIT 2806 (MAA) SOUND PAD WITH 50 STC AND 50 IIC IS REQUIRED FOR INSPECTION.
BLDG8337002020-07-01General construction402 RIVER ST(DMH-ProjctDox) INSTALL NEW PARTITION WALL TO CREATE 11' X 6'-9" KITCHEN PANTRY AND REMODEL KITCHEN AND ADJACENT POWDER ROOM IN TOWNHOME UNIT 402. INSTALL NEW LVL BEAM AND POSTS
BLDG8241822020-03-10General construction4216 SHERIDAN AVE SBasement Finish w/ Bedroom Alterations to existing basements or portions thereof shall have a ceiling height of not less than 6 feet 4 inches, including beams, girders, ducts or o
BLDG8195502020-03-03General construction413 RIVER STKitchen Remodel - Sheetrock Repair SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCOR
BLDG8180902020-02-10General construction402 RIVER STLower Level Remodel SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN.
BLDG8144062020-01-22General construction1627 WASHINGTON ST NEREPLACE WINDOWS DOORS AND BOARDED UP OPENINGS WITH NEW STORE FRONT GLASS WINDOWS AND DOORS (MAA) ******* ANY NEW LINTELS TO COORDINATE WITH STRUCTURAL DRAWINGS*********
BLDG8088892019-12-16General construction4133 DREW AVE SSTRUCTURAL REMODEL, REAR TWO STORY ADDITION WITH UNFINISHED BASEMENT STORAGE AREA WITH EGRESS WINDOW AND WELL OF A SINGLE FAMILY HOUSE. AAJ#2. ENGINEER FOR EARTH RETENTION SYS
BLDG8082142019-12-04General construction4155 CHOWEN AVE SNON-STRUCTURAL SFD BASEMENT REMODEL OF EXISTING LIVING ROOM AND BATHROOM AND INSTALL PARTITION FRAMING TO ENCLOSE MECHANICAL/STORAGE ROOM AND FINISH NEW APPROX. 12'x10' EXERCISE RO
BLDG8001832019-10-21General construction4621 EMERSON AVE SNON-STRUCTURAL REMODEL FOR NEW BATHROOM AND CLOSET IN SFD. (sza) INSTALL INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CONDITIONS. REPLACE WINDOW IN EXISTING OPENING. 6'-8'' MIN.
BLDG7785822019-06-10General construction215 10TH AVE S #204ALTER WALK THROUGH CLOSET TO CREATE HALL WITH SIDE CLOSET SPACES AT BATH AREA UNIT 204 CONDO (JAG)*** CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 *** 907
BLDG7785792019-06-10General construction4832 15TH AVE SNON STRUCTURAL REMODEL MAIN FLOOR BATH SAME LOCATIONS AT SFD (JAG)*** INSULATE EXTERIOR ASSEMBLIES FULL DEPTH AS EXPOSED ADDING VAPOR/AIR BARRIERS AS ALLOWED. NO WINDOW CHANGES.**
BLDG7621292019-04-30General construction608 RIVER ST
BLDG7621312019-04-08General construction5809 10TH AVE SSFD BASEMENT REMODEL - INSTALL PERIMETER ENERGY WALLS AND INTERIOR PARTITION WALLS WITH DRYWALL FINISHES TO EXPAND BATHROOM, ENCLOSE LAUNDRY ROOM AND MECHANICAL ROOM, INSTALL NEW C
BLDG7524932019-03-14General construction110 BANK ST #L1902Gut and remodel Condo in highrise including probable impact on rated assemblies. Quiey Walk below wood lam IIC tested at 60. The proposed memb below tile may or may not be accep
BLDG7524952019-02-27General construction404 RIVER STREMODEL/REPAIR EXISTING REAR PORCH OF TOWNHOUSE - UNIT#404. AAJ#1 - DEMOLITION OF EXISTING CONCRETE AND RUGBBER ROOF; DOOR AND RAILINGS AS NOTED IN WORK SPECIFICATIONS. - RE
BLDG7496172019-01-07General construction1 4TH AVE N #104REPLACE ALL EXISTING HALF WALL(S) ON EXISTING INTERIOR STAIRWAY(COMPLETE FLIGHT OF STAIRS) IN EXISTING TOWNHOUSE UNIT # 104. AAJ#1 - REMOVE ALL EXISTING HALF WALL ON COMPLET
BLDG7341102018-10-15General construction2885 KNOX AVE S #806REFINISH INTERIOR OF CONDO (NON PERMIT) AND INSTALL NEW FLOORING AT CONDO UNIT 806 (JAG) PREMIUM ENG CORETECH PLUS XL. STC 62 , IIC 62 UNDERLAY. CARBON MONOXIDE ALARMS REQUIRED I
BLDG7264462018-08-30General construction5042 QUEEN AVE Skitchen remodel: cabinets, countertops, floors etc. Not moving walls or fixture locations. NO STRUCTURAL WORK. LAYOUT STAYS THE SAME. UPDATING CABINETS AND FINISHES. NO NEW WIN
BLDG7147452018-06-19General construction3809 BEARD AVE SReplace sliding door and window in same location. Install metal roof in place of skylights. sck#2 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITI
BLDG7093362018-06-13General construction2112 DREW AVE SSTRUCTURAL REMODEL UPPER BATH WITH REVISED ROOF AND MAIN FLOOR BATH REMODEL AT SFD (JAG) ENGINEER: DEREK O PHILLIPS # 47507 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING
BLDG7138732018-06-13General construction1 4TH AVE N #104kitchen remodel unit # 104. SCK#2 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACC
BLDG6814222017-11-02General construction415 1ST ST NINTERIOR DEMO AND REMODEL TO MAIN LEVEL 1,678 S.F TENANT SPACE FOR TAILOR SHOP. (DMH#1) Const type: not given Occupancy: B 2015 MSBC occupant load: 15 (Archit calc

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Minneapolis permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →