COMPANY RECORD · MINNEAPOLIS, MN

Jack Pixley Chimney Sweeps And Masonry — permit history in Minneapolis, MN

Jack Pixley Chimney Sweeps And Masonry appears on 75 Minneapolis permit records from 2017 through 2026, most often general construction (68% of the record).

Permit categories

CategoryPermitsShare
General construction5168%
Mechanical / HVAC2432%

2 categories, as classified by the issuing authority. Small categories stay visible rather than being rounded away.

Activity by year

YearPermits issued
20173
201810
20199
20202
202115
202210
20236
202410
20255
20265

Busiest year on record: 2021, with 15 permits. One project can account for several filings, so read this as filing activity rather than workload.

Where they worked

Address in sourceMost recent permit
4720 YORK AVE S2026-06-09
244 UPTON AVE S2026-05-22
4145 22ND AVE S2026-05-13
150 MALCOLM AVE SE2026-05-13
3501 LINCOLN ST NE2025-05-22
134 PROSPECT AVE2025-02-28
2512 FARWELL PL2025-02-28
2417 BRYANT AVE S2024-11-18
3039 LINCOLN ST NE2024-08-30
3500 ALDRICH AVE S2024-08-30
4421 VINCENT AVE S2024-07-25
4157 BURTON LN2024-07-25
1526 ADAMS ST NE2024-07-19
2415 BRYANT AVE S2024-07-15

60 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

75 permits; open the 50 most recent
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
BLDG11835432026-06-09Mechanical / HVAC4720 YORK AVE Sreplace flue liner
BLDG11835542026-06-09General construction4720 YORK AVE Srebuild chimney 12 courses of brick roof line up.
BLDG11787822026-05-22General construction244 UPTON AVE Sinstall new stainless steel chimney liner.
BLDG11787842026-05-13General construction4145 22ND AVE S(DMH-Pdox) REBUILD EXTERIOR BRICK CHIMNEY TO GRADE TO SFD. NEW CONCRETE CAP & STAINLESS STEEL LINERS. LINERS TO MEET UL 1777. PRODUCT LABELS TO VISIBLE TO INSPECTOR. APPROV
BLDG11787832026-05-13General construction150 MALCOLM AVE SEREMOVE ALL FLUE TILE, NEW LINER. (JJL)
BLDG11198552025-05-22General construction3501 LINCOLN ST NECHIMNEY WORK ABOVE THE ROOFLINE We hereby propose to furnish materials and labor necessary to; Remove concrete wash and brickwork to roofline re build to current day code req
BLDG11078162025-02-28Mechanical / HVAC134 PROSPECT AVE
BLDG11078192025-02-28General construction134 PROSPECT AVErebuild chimney roof line up
BLDG11078232025-02-28Mechanical / HVAC2512 FARWELL PL
BLDG11078242025-02-28General construction2512 FARWELL PLrebuild chimney roof line up
BLDG10949452024-11-18General construction2417 BRYANT AVE SREPLACE CHIMNEY LINER
BLDG10756342024-09-23General construction2417 BRYANT AVE SREMOVE CONCRETE WASH AND BRICKWORK TO LOWEST PART OF THE ROOFLINE ON CHIMINEY VENTING FIREPLACE. REBUILD TO CURRENT DAY CODE REQUIREMENTS WITH "BEST MATCH BRICK". PROVIDE CONCRET
BLDG10813092024-08-30General construction3039 LINCOLN ST NE
BLDG10813112024-08-30General construction3500 ALDRICH AVE S
BLDG10734112024-07-25General construction4421 VINCENT AVE S(DMH - ProjectDox) INSTALL NEW STEEL CHIMNEY LINER AND FIRE BOX LINER WITH "AHERN" FIREPLACE SYSTEM. APPROVED PLANS AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDE
BLDG10734122024-07-25General construction4157 BURTON LN(DMH - ProjectDox) INSTALL NEW STEEL CHIMNEY LINER AND FIRE BOX LINER WITH "AHERN" FIREPLACE SYSTEM. APPROVED PLANS AND PERMIT MUST BE ON SITE BEFORE INSPECTIONS WILL BE PROVIDE
BLDG10734142024-07-19General construction1526 ADAMS ST NE
BLDG10697482024-07-15General construction2415 BRYANT AVE S
BLDG10575782024-05-14General construction4716 YORK AVE Sremove flue tile liner replace with stainless steel liner UL 1777 install chimilator damper and concrete crown with drip
BLDG10515432024-04-04General construction745 51ST ST E
BLDG10346982023-11-30General construction5015 GLADSTONE AVECHIMNEY REPAIR/REMODEL 2020 MSRC
BLDG10200292023-10-03General construction3205 EXCELSIOR BLVDrebuild top of masonry chimney and install stainless steel liner.
BLDG10158522023-09-07General construction5708 VINCENT AVE SMasonry Repair and Reline Chimney Flue Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING,
BLDG9883172023-03-29General construction4252 COLUMBUS AVEREMOVE ALL FLUE TILE LINER AND RELINE USING STAINLESS STEEL LINER. (JJL) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK.
BLDG9883182023-03-29General construction5149 14TH AVE SREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE. USE 9" STAINLESS STEEL LINER. REMOVE CONCRETE WASH AND 10 COURSE OF BRICK. REBUILD. (JJL) SEPARATE PERMITS ARE REQUIRED FOR
BLDG9843172023-03-13General construction2115 EAST LAKE OF THE ISLES PKWYREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMNEY FOR WOOD BURNING FIREPLACE, USING 12" ROUND STAINLESS STEEL LINER SYSTEM. REMOVE CONCRETE WASH AND PROVIDE CONCRE
BLDG9674192022-10-26General construction412 LUVERNE AVENEW WOOD BURNING FIREPLACE (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, A
BLDG9674122022-10-26General construction5004 BELMONT AVE SNEW WOOD BURNING FIREPLACE (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, A
BLDG9614362022-09-02General construction3554 ARCHITECT AVE
BLDG9584952022-08-18General construction5205 DREW AVE SCHIMNEY REPAIR LINER, BRICK, CONCRETE CROWN. (JJL) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE AL
BLDG9307752022-07-14General construction4628 YORK AVE SINSTALL WOOD BURNING FIREPLACE SYSTEM AND STAINLESS STEEL FLUE LINER. Product literature must say tested per UL 127. Literature and installation instructions must be on site for
BLDG9519042022-06-30General construction4153 22ND AVE SRELINE AND REBUILD CHIMNEY FROM THE ROOFLINE UP. INCLUDES NEW CROWN, DAMPER,WATER REPELLENT AND CONCRETE WASH
BLDG9307602022-03-08General construction3107 JOHNSON ST NE2 courses of brick on chimney roof line up
BLDG9303912022-03-02General construction15 MELBOURNE AVE SERemove concrete wash & brickwork to roofline; rebuild to current day code requirements with "best match brick"; provide conrete crown with overhang and drip ledge as outlines in ar
BLDG9303932022-03-02General construction17 MELBOURNE AVE SERemove concrete wash and brickwork to roofline; rebuild to current day code requirements with "best match brick"; provide concrete crown with overhang and drip ledge as outlined in
BLDG9278742022-02-15General construction1910 QUINCY ST NERELINE FLUE
BLDG9100212021-09-30General construction1770 EMERSON AVE SREMOVE CONCRETE WASH AND BRICKWORK TO LOWEST ROOFLINE; REBUILD TO CURRENT DAY CODE REQUIREMENTS WITH "BEST MATCH BRICK"; PROVIDE CONCRETE CROWN WITH OVERHANG AND DRIP EDGE AS OUTLI
BLDG9022652021-08-09General construction2823 40TH ST WREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMNEY FOR MAIN LEVEL WOOD BURNING FIREPLACE USING 9" ROUND STAINLESS STEEL LINER SYSTEM. REMOVE CONCRETE WASH AND BRICK O
BLDG8935712021-06-17General construction4825 WASHBURN AVE STEAR DOWN CHIMNEY TO ROOFLINE. REBUILD WITH NEW BRICK. NEW CONCRETE CROWN W DAMPER AND FLASHING. (JJL)
BLDG8935662021-06-15General construction2542 GARFIELD ST NEREMOVE CONCRETE WASH AND BRICKWORK TO ROOFLINE. REBUILD TO CURRENT DAY CODE REQUIREMENTS WITH "BEST MATCH BRICK" PROVIDE CONCRETE CROWN WITH OVERHANG AND DRIP LEDGE AS OUTLINED
BLDG8849762021-05-11General construction4556 PORTLAND AVEREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMENY FOR MAIN LEVEL WOOD BURNING FIREPLACE, USING 10" ROUND STAINLESS STEEL LINER SYSTEM; REMOVE CONCRETE WASH AND PROVID
BLDG8849772021-05-11General construction2200 OLIVER AVE SREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMENY FOR MAIN LEVEL WOOD BURNING FIREPLACE, USING 10" ROUND STAINLESS STEEL LINER SYSTEM; PROVIDE CONCRETE CROWN WITH OVE
BLDG8849722021-05-11General construction1710 61ST ST WREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMENY FOR BOTH OPEN HEARTH WOOD BURNING FIREPLACES, USING 10" ROUND STAINLESS STEEL LINER SYSTEM; INSTALL 4" SMOKE GAURDS;
BLDG8803672021-04-08Mechanical / HVAC1230 WEST MINNEHAHA PKWYCHIMNEY WORK FOR WOOD BURNING FIREPLACE
BLDG8803632021-04-08General construction1230 WEST MINNEHAHA PKWYREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMNEY FOR WOOD BURNING FIREPLACE. USING 8" ROUND STAINLESS STEEL LINER SYSTEM(UL 1777 LISTED WITH MANUFACTURER'S LIFETIM
BLDG8804062021-04-08General construction56 UPTON AVE SREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMNEY FOR MAIN LEVEL WOOD BURNING FIREPLACE. USING 10" ROUND STAINLESS STEEL LINER SYSTEM(UL 1777 LISTED WITH MANUFACTUR
BLDG8804112021-04-08Mechanical / HVAC56 UPTON AVE SCHIMNEY WORK FOR WOODBURNING FIREPLACE
BLDG8714612021-02-08Mechanical / HVAC3535 38TH AVE SREMOVE ALL FLUE TILE LINER MATERIALS AND RELINE MASONRY CHIMNEY FOR MAIN LEVEL WOOD BURNING FIREPLACE USING 10" ROUND STAINLESS STEEL LINER SYSTEM(UL 1777 LISTED WITH MANUFACTUERE'
BLDG8714712021-02-08Mechanical / HVAC5037 COLFAX AVE Swood burning fireplance
BLDG8714602021-02-08General construction3535 38TH AVE SREMOVE CONCRETE WASH AND 27 COURSES OF BRICK ON CHIMNEY. REBUILD TO CURRENT DAY CODE REQUIREMENTS USING "BEST MATCH BRICK". PROVIDE CONCRETE CROWN WITH OVERHANG AND DRIP LEDGE AS

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Minneapolis permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →