COMPANY RECORD · MINNEAPOLIS, MN
Edgework Design Build — permit history in Minneapolis, MN
Edgework Design Build appears on 50 Minneapolis permit records from 2017 through 2026, all of them general construction.
Permit categories
| Category | Permits | Share |
|---|---|---|
| General construction | 50 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2017 | 5 |
| 2018 | 2 |
| 2019 | 8 |
| 2020 | 5 |
| 2021 | 11 |
| 2022 | 4 |
| 2023 | 3 |
| 2024 | 4 |
| 2025 | 4 |
| 2026 | 4 |
Busiest year on record: 2021, with 11 permits. One project can account for several filings, so read this as filing activity rather than workload.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 2012 BRYANT AVE S | 2026-08-19 |
| 4012 GARFIELD AVE | 2026-06-11 |
| 31 UPTON AVE S | 2026-06-10 |
| 1920 1ST ST S | 2026-05-18 |
| 432 PENN AVE S | 2025-10-08 |
| 629 QUEEN AVE S | 2025-07-01 |
| 125 50TH ST W | 2025-04-03 |
| 133 50TH ST W | 2024-12-05 |
| 1208 LAKEVIEW AVE S | 2024-10-03 |
| 1206 EDLIN PL | 2024-03-28 |
| 3707 HARRIET AVE | 2024-03-04 |
| 3312 IRVING AVE S | 2023-12-08 |
| 1435 LAKEVIEW AVE S | 2023-09-26 |
| 2316 HUMBOLDT AVE S | 2023-07-10 |
44 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
50 permits; open the full list
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| BLDG1194212 | 2026-08-19 | General construction | 2012 BRYANT AVE S | REMODEL BASEMENT. ADDING BEDROOM. NO STRUCTURAL WORK. (JJL) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED | |
| BLDG1179115 | 2026-06-11 | General construction | 4012 GARFIELD AVE | (DMH-Pdox) 22'-6"X 12' TWO-STORY REAR ADDTION TO SFD OVER INSULATED FLOORS AND 3 HELICAL PIERS. - 2020 MNSBC NEW REAR ENTRY MUDROOM AND OFFICE. NEW 2ND FLOOR BEDROOM, CLOSET A | |
| BLDG1180407 | 2026-06-10 | General construction | 31 UPTON AVE S | BUILD DECK ON HELICAL PIERS Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEA | |
| BLDG1172877 | 2026-05-18 | General construction | 1920 1ST ST S | (DMH-Pdox) REMODEL 2ND FLOOR COMMUNITY ROOMS AND NEW EXTERIOR ROOFTOP PERGOLAS. RELOCATE PARTITION WALL BETWEEN EXERCISE ROOM AND COMMON ROOM TO ENLARGE EXERCISE SPACE. RELOCATE | |
| BLDG1138445 | 2025-10-08 | General construction | 432 PENN AVE S | Front stoop foundation, 4 window replacements and 1 egress window well, re-work associated electrical as per plan, overlay living/dining room ceiling, patch drywall and paint walls | |
| BLDG1129405 | 2025-07-01 | General construction | 629 QUEEN AVE S | Siding replacement on property | |
| BLDG1111912 | 2025-04-10 | General construction | 629 QUEEN AVE S | MAIN & UPPER LEVEL MODIFICATIONS (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBI | |
| BLDG1111999 | 2025-04-03 | General construction | 125 50TH ST W | Kitchen Remodel Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 Windows installed under this permit shall meet the requirements of the current | |
| BLDG1094144 | 2024-12-05 | General construction | 133 50TH ST W | BATHROOM REMODEL. IF WINDOW IS REPLACED NEAR BATHTUB, WINDOW MUST HAVE TEMPERED GLASS. NO STRUCTURAL WORK. (JJL) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA | |
| BLDG1082482 | 2024-10-03 | General construction | 1208 LAKEVIEW AVE S | Garage expansion w/ deck above Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEA | |
| BLDG1050859 | 2024-03-28 | General construction | 1206 EDLIN PL | (DMH-ProjectDox) CONSTRUCT 12' X 5' FRONT ENTRY ADDITION TO SFD WITH NEW FROST FOUNDATION, CONCRETE LANDING & STEPS, SPRAY FOAM INSULATIONS AND FLAT ROOF. REMOVE & REPLACE EXTER | |
| BLDG1045775 | 2024-03-04 | General construction | 3707 HARRIET AVE | NON-STRUCTURAL BASEMENT REMODEL OF LIVING ROOM AND OFFICE. DEMO INTERIOR PARTITION FRAMING ENCLOSING EXISTING OFFICE ROOM AND CLOSETS TO ENLARGE THE LIVING ROOM TO 32'x10' AND OPEN | |
| BLDG1035347 | 2023-12-08 | General construction | 3312 IRVING AVE S | CONVERT PORCH TO DECK AND REMODEL UPPER BATHRM 2/2/24 approved post-issue revision to 2) Goliath Tech piles per installation checklist uploaded 1/29/24 to be filled out and provide | |
| BLDG1012609 | 2023-09-26 | General construction | 1435 LAKEVIEW AVE S | ADDITION ABOVE GARAGE AND INTERIOR REMODEL OF HOUSE (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR | |
| BLDG1004310 | 2023-07-10 | General construction | 2316 HUMBOLDT AVE S | SFD BATHROOM REMODEL - DEMO ADJACENT CLOSETS TO EXPAND ATTIC LEVEL BATHROOM AND CREATE LAUNDRY NOOK. RELOCATE TUB AND CREATE WALK-IN SHOWER. REPLACE LAV WITH DOUBLE VANITY. DEMO | |
| BLDG963429 | 2022-12-15 | General construction | 3137 HOLMES AVE S | EXPANSION OF FOUNDATION, AND OTHER FLOORS. REMODEL INTERIOR. SEE ENGINEERS DRAWING FOR 2ND FLOOR DECK. FLOOR JOISTS TO CANTILEVER OUT BEYOND WALL. ENGINEER TO REVIEW STRUCTURAL | |
| BLDG973873 | 2022-12-06 | General construction | 4427 EAST LAKE HARRIET PKWY | ALTERATIONS TO WINE CELLAR & FAMILY ROOM Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, | |
| BLDG970903 | 2022-11-08 | General construction | 1237 LAKEVIEW AVE S | REMODEL KITCHEN. REPLACE WINDOW. ADD BATHROOM. Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICA | |
| BLDG950947 | 2022-07-15 | General construction | 3142 ARTHUR ST NE | BATHROOM REMODEL (MAA) Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AI | |
| BLDG916384 | 2021-11-17 | General construction | 620 QUEEN AVE S | KITCHEN REMODEL OF EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS) - UPDATE ELECTRICAL, PLUMBING AND MECHANICAL WORK AS NEEDED PER CODE REQUIREMENTS. APPROVED PLA | |
| BLDG911001 | 2021-11-15 | General construction | 4432 30TH AVE S | (DMH - ProjectDox) INSTALL NEW FOUNDATIONS TO EXPAND AND REBUILD FRONT CONCRETE LANDING, STEPS AND ROOF COVERING TO SFD. REPLACE FRONT AND SIDE ENTRY DOORS WITH NEW AND SELECT W | |
| BLDG906048 | 2021-09-09 | General construction | 4408 THOMAS AVE S | REMODEL EXISTING 2ND FLOOR BATHROOM OF A SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLAN). - REPLACE BATHROOM FIXTURES WITH NEW FIXTURES AND WINDOW(USING SAME OPENING) AS REQUIRED | |
| BLDG895043 | 2021-08-03 | General construction | 2316 MOUNT VIEW AVE | KITCHEN REMODEL AND WINDOW INSERTS. NO STRUCTURAL WORK. (JJL) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON M | |
| BLDG898941 | 2021-08-02 | General construction | 628 QUEEN AVE S | (11/01/2021) Basement FINISH IS NON-HABITABLE SPACE-PER INSPECTION IT DOES NOT MEET R305.2.1 6 4 MINIMUM CEILING HEIGHT AND/OR R305.2.2 6 4 MINIMUM STAIR HEADRO | |
| BLDG895103 | 2021-07-13 | General construction | 2304 MOUNT VIEW AVE | MODIFIY EXISTING REAR WOOD DECK TO ENCLOSE NEW PERGOLA AND CONVERT PORTION OF DECK TO NEW MUDROOM(PORTICO) ON 2ND LEVEL OF EXISTING TWO FAMILY DWELLINGS. AAJ (PROJECT DOX PLANS) | |
| BLDG894724 | 2021-06-24 | General construction | 1824 19TH AVE NE | RELOCATE AND REMODEL 2ND FLOOR BATHROOM. NO STRUCTURAL WORK. IF WINDOW IS REPLACED, SAFETY GLAZING REQUIRED. (JJL) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AN | |
| BLDG885924 | 2021-05-28 | General construction | 3039 12TH AVE S | KITCHEN REMODEL TO SFD INCLUDING REMOVAL OF EXISTING WALL FINISH (sza) INSTALL INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CONDITIONS. WINDOW REPLACEMENT IN EXISTING OPENINGS | |
| BLDG882259 | 2021-04-26 | General construction | 5540 NEWTON AVE S | basement finish including bathroom and living area. sck Building Code: 2020 MNSBC/2018 IRC Energy Code: MINNESOTA RULES CHAPTER 1322 SEPARATE PERMITS ARE REQUIRED FOR ELECT | |
| BLDG880540 | 2021-04-22 | General construction | 1866 26TH ST E | CONSTRUCT APPROX. 8' X 8' ONE STORY ADDN FOR MUDROOM AND 7' X 8' OPEN DECK AT NE CORNER OF DWELLING. 5'-6" SIDE SETBACK NOTED, WITH EAVES NOT CLOSER THAN 5' TO PROPERTY LINE. BOT | |
| BLDG880878 | 2021-04-20 | General construction | 2743 BENJAMIN ST NE | (DMH - ProjectDox) KITCHEN REMODEL TO SFD. WHERE REMOVAL OF EXISTING WALL FINISHES TAKES PLACE, INSTALL INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CONDITIONS AND DRYWALL FIN | |
| BLDG850109 | 2020-10-20 | General construction | 420 PENN AVE S | CONSTRUCT 12'x20' WOOD FRAME GARAGE ADDITION TO EXISTING ATTACHED GARAGE. STRUCTURAL DESIGN, INCLUDING STEPPED FOUNDATION AND WIND (WALL BRACING) BY STRUCTURAL ENGINEER: DEVON HUNT | |
| BLDG848517 | 2020-10-20 | General construction | 121 WASHINGTON AVE S #1201 | INTERIOR RENODEL OF EXISTING RESIDENTIAL UNIT #1201 OF AMN APARTMENT BUILDING. AAJ (PROJECT DOCT PLANS. ***SOUND MAT SPECIFICATIONS: PROVIDE MINIMUM STC/ IIC RATING(S) OF 50 AS | |
| BLDG840809 | 2020-08-03 | General construction | 621 UPTON AVE S | MAIN FLOOR REMODEL OF EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLAN). - REMODEL EXISTING KITCHEN AREA TO CREATE NEW LAYOUT. - INSTALL NEW PARTITION WALLS WITH DRYWALL | |
| BLDG825068 | 2020-06-23 | General construction | 3455 BLOOMINGTON AVE | Convert B to E day care. certificate of occupancy required yes 8/18/2020 See 3 drawings with approved revisions attached in ELMS mechanical plans required for certificate of o | |
| BLDG833896 | 2020-05-19 | General construction | 204 RUSSELL AVE S | reside houese and replace front door | |
| BLDG795323 | 2019-09-20 | General construction | 5547 HARRIET AVE | Kitchen Remodel - Enlarge Opening to Dining Room SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQ | |
| BLDG793535 | 2019-09-10 | General construction | 31 UPTON AVE S | Kitchen Remodel SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT | |
| BLDG789738 | 2019-08-15 | General construction | 505 CEDAR LAKE RD S | CONSTRUCT_14_ X _5_ TREATED WOOD DECK AT FRONT YARD OF SFD WITH 2 X_8_ JOISTS, (sza) 2X_8_ BEAMS, GUARDRAIL, STAIRS, HANDRAIL, TREATED WOOD POSTS AND FOOTING LOCATIONS. Grippable | |
| BLDG778209 | 2019-06-11 | General construction | 505 CEDAR LAKE RD S | Structural framing repairs and improvements along with associated interior finish repairs. Roofing system to be under separate permit. | |
| BLDG778211 | 2019-06-06 | General construction | 204 RUSSELL AVE S | NON-STRUCTURAL REMODEL OF 2 BATHROOMS KITCHEN AND UPPER LEVEL MASTER SUITE INCLUDING REMOVAL OF EXISTING FINISHES. (sza) INSTALL INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CON | |
| BLDG771081 | 2019-05-14 | General construction | 505 CEDAR LAKE RD S | REMOVE EXISTING ROOF AND INSTALL NEW FLAT ROOF STRUCTURE (FLAT ROOF TRUSSES, 3/4" PLYWOOD) AND EPDM ROOFING AT EXISTING 20'x23' DETACHED GARAGE. REPLACE OH GARAGE DOOR, WINDOWS (3 | |
| BLDG757595 | 2019-03-11 | General construction | 4617 BRYANT AVE S | Note 6/14/19: As per Building Inspector Vicki Carey - the basement is non-habitable space. The bedroom is not a legal bedroom (beam Basement Finish w/ Bedroom | 5 Window R | |
| BLDG750212 | 2019-01-11 | General construction | 4125 DREW AVE S | Basement Finish Update Alterations to existing basements or portions thereof shall have a ceiling height of not less than 6 feet 4 inches, including beams, girders, ducts or other | |
| BLDG732987 | 2018-10-09 | General construction | 432 PENN AVE S | SFD BASEMENT REMODEL TO REMOVE EXISTING SAUNA TO EXPAND FAMILY ROOM, INSTALL FRAMING TO ENCLOSE NEW FULL BATHROOM AND NEW APPROX. 10'x15' OFFICE. INSTALL PERIMETER ENERGY WALLS (S | |
| BLDG721992 | 2018-08-03 | General construction | 2412 MOUNT VIEW AVE | REMOVING OLD DECK AND PERGOLA, AND ADDING NEW DECK AND STAIRS. DECK TO BE THE SAME SIZE AS BEFORE. ELINATING ONE COLUMN, USING GLULAM BEAM TO SPAN EXTERIOR. BEAM WILL BE WRAPPED | |
| BLDG680649 | 2017-10-24 | General construction | 205 CECIL ST SE | INSTALL 2 SKYLIGHT WINDOWS WITH (2)2x6 FRAMING IN SLOPED ROOF AT ATTIC AND INSTALL CLOSED CELL SPRAY FOAM INSULATION AND DRYWALL FINISHES FOR APPROX. 16'x10' OFFICE SPACE AT SFD AT | |
| BLDG672931 | 2017-08-30 | General construction | 5549 ALDRICH AVE S | BASEMENT REMODEL - NEW EGRESS WINDOW - OFFICE USE (BEDROOM USE MAY OCCUR AFTER VERIFCATION OF HEADROOM HEIGHT ) (WSS) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND | |
| BLDG672934 | 2017-08-30 | General construction | 5305 46TH AVE S | CONVERT EXISTING PORCH INTO LIVING SPACE - NEW BATHROOM (WSS) SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOX | |
| BLDG668319 | 2017-07-31 | General construction | 3333 SAINT LOUIS AVE | NON-STRUCTURAL BATHROOM REMODEL TO SFD INCLUDING REMOVAL OF EXISTING FINISHES. INSTALL INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CONDITIONS. NO WINDOW REPLACEMENT BATHROOM WAL | |
| BLDG628173 | 2017-01-03 | General construction | 3110 LAKE ST W | Unit# 131 2nd floor bath & laundry rooms Non-structural remodel of existing bathroom and add new bathroom and laundry facilities on second floor of unit. |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Minneapolis permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →
