COMPANY RECORD · DETROIT, MI
Mcchesney Electric — permit history in Detroit, MI
Mcchesney Electric appears on 68 Detroit permit records from 2019 through 2026, all of them electrical.
Permit categories
| Category | Permits | Share |
|---|---|---|
| Electrical | 68 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2019 | 10 |
| 2020 | 6 |
| 2021 | 13 |
| 2022 | 20 |
| 2023 | 9 |
| 2024 | 5 |
| 2025 | 3 |
| 2026 | 2 |
Busiest year on record: 2022, with 20 permits. One project can account for several filings, so read this as filing activity rather than workload.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 20444 Renfrew Rd | 2026-06-15 |
| 790 Lakewood St | 2026-04-08 |
| 18920 Santa Rosa Dr | 2025-11-17 |
| 6720 W Outer Dr, Apt 210 | 2025-07-14 |
| 16170 Muirland St | 2025-06-26 |
| 14377 Ashton Rd | 2024-12-05 |
| 702 W Canfield St | 2024-07-12 |
| 13575 Mansfield St | 2024-02-21 |
| 4708 Avery St | 2024-02-13 |
| 18994 Oak Dr | 2023-12-11 |
| 12520 E Outer Dr | 2023-10-31 |
| 20150 Briarcliff Rd | 2023-04-25 |
| 10610 Whitehill St | 2023-04-25 |
| 18840 John R St | 2023-04-21 |
57 distinct addresses on record; the 14 most recent are shown. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
68 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| ELE2026-02271 | 2026-06-15 | Electrical | 20444 Renfrew Rd | OVERHEAD TO UNDERGROUND CONVERSION. PANEL ONLY IN GARAGE. NEW 200 AMP SERVICE - UNDERGROUND INSPECTION, TEMP SERVICE, 100 AMP FEEDER TO EXISTING LOADCENTER WITHIN BASMENT OF RESIDE | |
| ELE2026-01305 | 2026-04-08 | Electrical | 790 Lakewood St | INSTALL NEW 100 AMP SERVICE, PANEL & DISCONNECT. REWIRE 1ST & 2ND FLOOR. | |
| ELE2025-05147 | 2025-11-17 | Electrical | 18920 Santa Rosa Dr | UPGRADE RESIDENTAL SERVICE 200 AMP | |
| ELE2025-03135 | 2025-07-14 | Electrical | 6720 W Outer Dr, Apt 210 | REPLACEMENT OF FIXTURES AND DEVICES IN KITCHEN OF UNIT 210 | |
| ELE2025-02892 | 2025-06-26 | Electrical | 16170 Muirland St | ADD ON TO EXISTING PERMIT - ELE2024-05138 (6) SMOKE DETECTORS | |
| ELE2024-05140 | 2024-12-05 | Electrical | 14377 Ashton Rd | BASEMENT REMODEL | |
| ELE2024-05138 | 2024-12-05 | Electrical | 16170 Muirland St | REWIRE 1ST FLOOR & BASEMENT REPLACE FIXTURES & DEVICES ON 2ND FLOOR NEW 100 AMP SERVICE & PANEL | |
| ELE2024-02698 | 2024-07-12 | Electrical | 702 W Canfield St | INTEROR AND EXTERIOR LIGHTNG MUDROOM REMODEL | |
| ELE2024-00666 | 2024-02-21 | Electrical | 13575 Mansfield St | BATHROOM REMODEL, KTICHEN CEILING REPAIR, LIGHTING CIRCUIT | |
| ELE2024-00565 | 2024-02-13 | Electrical | 4708 Avery St | 1ST FLOOR REMODEL OF KITCHEN, BATH AND LAUNDRY | |
| ELE2023-04570 | 2023-12-11 | Electrical | 18994 Oak Dr | REMODELING OF (3) BATHROOMS | |
| ELE2023-04014 | 2023-10-31 | Electrical | 12520 E Outer Dr | ADD ON TO PERMIT ELE2023-02013 TO REPLACE (1) 100 AMP SERVICE | |
| ELE2023-02013 | 2023-06-06 | Electrical | 12520 E Outer Dr | REWIRE 2 BEDROOMS AND 1 HALLWAY AND SMOKE DETECTOR SYSTEM | |
| ELE2023-01516 | 2023-04-25 | Electrical | 20150 Briarcliff Rd | COMPLETE REWIRE OF ENTIRE HOME DUE TO FIRE | |
| ELE2023-01515 | 2023-04-25 | Electrical | 10610 Whitehill St | REPAIRS PER VIOLATIONS REPORT SPL2023-00660 INSPECTION ID 32395513 | |
| ELE2023-01469 | 2023-04-21 | Electrical | 18840 John R St | CODE REPAIRS PER INSPECTION | |
| ELE2023-00852 | 2023-03-09 | Electrical | 15775 Sorrento St | demod old service and replaced with new. installed GFCI outside near service. | |
| ELE2023-00555 | 2023-02-11 | Electrical | 1066 Burns St | REWIRE KITCHEN AND LAUNDRY DUE TO WATER DAMAGE. | |
| ELE2023-00373 | 2023-01-30 | Electrical | 1995 Balmoral Ave | INSTALL 200 AMP SERVICE AND RELOCATE METER TO EXTERIOR OF HOME | |
| ELE2022-05010 | 2022-12-20 | Electrical | 16814 Warwick St | 220 VOLT POWER CIRCUIT TO MINI SPLIT 110 VOLT EXTERIOR GFCI CIRCUIT FOR WEATHERPROOF DUPLEX RECEPTACLE NEAR MINI SPLIT | |
| ELE2022-04734 | 2022-11-30 | Electrical | 12136 Santa Rosa Dr | WIRING OF (1) FURNACE WIRING OF (1) AIR CONDITIONER WIRING OF (1) EXTERIOR GFCI RECEPTACLE | |
| ELE2022-04735 | 2022-11-30 | Electrical | 12134 Santa Rosa Dr | WIRING OF (1) FURANCE WIRING OF (1) AIR CONDITIONER WIRING OF (1) EXTERIOR GFCI RECEPTACLE WIRING OF (1) LIGHT AND GFCI RECEPTACLE | |
| ELE2022-04539 | 2022-11-16 | Electrical | 3707 Hunt St | INSTALL 110 VOLT CIRCUIT FOR FURNACE INSTALL 110 VOLT GFCI RECEPTACLE NEAR FURNACE | |
| ELE2022-04364 | 2022-11-03 | Electrical | 13930 Chatham St | ADD ON TO EXISTING PERMIT ELEC2022-03797 | |
| ELE2022-03797 | 2022-09-23 | Electrical | 13930 Chatham St | WIRE NEW AIR CONDITIONER NEW CIRCUIT FOR EXTERIOR GFCI | |
| ELE2022-03215 | 2022-08-12 | Electrical | 18939 Pennington Ave | WIRE A NEW AIR CONDITIONER. WIRE A NEW EXTERIOR GFCI RECEPTACLE. | |
| ELE2022-02962 | 2022-07-28 | Electrical | 4207 Haverhill St | REPLACE EXTERIOR RISER CABLES, METER CANS, ENTRANCE CABLES AND GROUNDING ELECTRODE SYSTEM. | |
| ELE2022-02961 | 2022-07-28 | Electrical | 4205 Haverhill St | REPLACE EXTERIOR RISER CABLES, METER CANS, ENTRANCE CABLES AND GROUNDING ELECTRODE SYSTEM. | |
| ELE2022-02471 | 2022-06-27 | Electrical | 3675 Gilbert St | WIRE NEW MINI SPLIT SYSTEM WIRE EXTERIOR GFCI RECEPTACLE | |
| ELE2022-02353 | 2022-06-17 | Electrical | 16844 Plainview Ave | WIRE NEW AIR CONDITIONER | |
| ELE2022-02343 | 2022-06-17 | Electrical | 5385 Hereford St | WIRING FOR NEW AIR CONDITIONER REPLACE EXTERIOR GFCI AND IN USE COVER | |
| ELE2022-01918 | 2022-05-17 | Electrical | 17138 Ohio St | NEW A/C CIRCUIT AND GFCI RECEPTACLE | |
| ELE2022-01818 | 2022-05-10 | Electrical | 18606 Bloom St | BEDROOM REWIRE, BATHROOM UPGRADE DUE TO WATER DAMAGE, SMOKE DETECTOR SYSTEM | |
| ELE2022-01498 | 2022-04-20 | Electrical | 1155 Virginia Park St | MINI SPLIT UNIT INSTALL | |
| ELE2022-01497 | 2022-04-20 | Electrical | 8188 House St | INSTALL CIRCUIT FOR AIR CONDITIONER UNIT | |
| ELE2022-00968 | 2022-03-15 | Electrical | 4221 Cass Ave | WIRE NEW ELECTRIC HOT WATER TANK - 30 AMP 220 VOLT | |
| ELE2022-00780 | 2022-03-02 | Electrical | 19400 Buffalo St | CIRCUIT FOR A/C UNIT EXTERIOR GFCI RECEPTACLE | |
| ELE2022-00698 | 2022-02-24 | Electrical | 3806 Glendale St | CIRUCIT FOR FURNACE | |
| ELE2022-00552 | 2022-02-11 | Electrical | 13220 Greenfield Rd | WILL NEED A TOTAL OF (3) INSPECTIONS - (1) PRE-INSPECTION WALK THROUGH, (1) ROUGH & (1) FINAL LIGHTING REPLACEMENT THROUGHOUT DUE TO SMOKE DAMAGE | |
| ELE2021-05575 | 2021-12-15 | Electrical | 2801 17th St | REPAIRS DUE TO VEHICLE DAMAGE | |
| ELE2021-04085 | 2021-09-29 | Electrical | 13140 Conner St | PROVIDE NEW WIRING, SERVICE PANEL AND FEEDER FOR UNITS 20, 21, 22, 23, 24, 25 & 26 | |
| ELE2021-04055 | 2021-09-27 | Electrical | 13140 Conner St | PROVIDE NEW WIRING, SERVICE PANEL AND FEEDER FOR UNITS 5, 6, 7, 8, 9, 10 & 11. | |
| ELE2021-04086 | 2021-09-27 | Electrical | 13140 Conner St | PROVIDE NEW WIRING, SERVICE PANEL AND FEEDER FOR UNITS 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46 & 49 | |
| ELE2021-04087 | 2021-09-27 | Electrical | 13140 Conner St | PROVIDE (2) NEW CIRCUITS FOR LIGHTING AND SMOKE DETECTORS AND EXIT SIGNS | |
| ELE2021-02934 | 2021-07-21 | Electrical | 8820 W Seven Mile | ELECTRICAL REPAIRS DUE TO FIRE | |
| ELE2021-02216 | 2021-06-04 | Electrical | 1066 Burns St | WALK THROUGH WITH ELECTRICAL INSPECTOR | |
| ELE2021-01886 | 2021-05-12 | Electrical | 3901 Bedford St | ADD ONTO PERMIT ELE2021-01854 SMOKE DETECTORS | |
| ELE2021-01854 | 2021-05-10 | Electrical | 3901 Bedford St | KITCHEN REMODEL | |
| ELE2021-00789 | 2021-03-02 | Electrical | 13140 Conner St | ADD ON TO EXISTING PERMIT ELE2021-00632 - INSTALL (2) CIRCUITS, EXITS & EMERGENCY FIXTURES AND DC WIFI SMOKE DETECTORS. | |
| ELE2021-00632 | 2021-02-19 | Electrical | 13140 Conner St | (1) HOUR OF TIME WALK THROUGH WITH INSPECTOR |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Detroit permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →