COMPANY RECORD · NEW ORLEANS, LA
James Nolan Honore' Jr — permit history in New Orleans, LA
James Nolan Honore' Jr appears on 65 New Orleans permit records from 2017 through 2026, all of them electrical.
Permit categories
| Category | Permits | Share |
|---|---|---|
| Electrical | 65 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2017 | 10 |
| 2018 | 6 |
| 2019 | 2 |
| 2020 | 8 |
| 2021 | 2 |
| 2022 | 6 |
| 2023 | 3 |
| 2024 | 9 |
| 2025 | 11 |
| 2026 | 8 |
Busiest year on record: 2025, with 11 permits. One project can account for several filings, so read this as filing activity rather than workload.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 517 S Scott St | 2026-08-21 |
| 3322 Short St | 2026-07-22 |
| 4239 S Claiborne Ave | 2026-07-13 |
| 4600 Francis Dr | 2026-07-13 |
| 2100 Saint Charles Ave Unit 4E | 2026-06-24 |
| 6371 Louis Xiv St | 2026-06-02 |
| 2767 Gladiolus St | 2026-05-21 |
| 127 Porteous St | 2026-05-14 |
| 11739 River Rd | 2025-11-19 |
| 2348 Constance St | 2025-09-24 |
| 4708 Washington Ave | 2025-08-28 |
| 7331 Lake Barrington Dr | 2025-08-07 |
| 1725 Saint Andrew St A | 2025-07-25 |
| 8214 Pritchard Pl | 2025-07-24 |
55 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $0 to $112,000, median $0. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
65 permits; open the 50 most recent
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| 26-24450-SERV | 2026-08-21 | Electrical | 517 S Scott St | Electrical renovation. Rewire areas according to plans. Install a new 200amp service panel. with 32 ARC Fault breakers. Install a new grounding system and perform final trim out of | $5,600 |
| 26-19456-EVCH | 2026-07-22 | Electrical | 3322 Short St | Will install a 400-amp service with an 80-amp circuit for EV chargers and power for 7 light poles.as per plans on 25-35308-NEWC | $112,000 |
| 26-20422-EVAC | 2026-07-13 | Electrical | 4239 S Claiborne Ave | Will perform a vacancy inspection for meter release. | $500 |
| 26-20423-EVAC | 2026-07-13 | Electrical | 4600 Francis Dr | Will perform a vacancy inspection . | $500 |
| 26-17800-SERV | 2026-06-24 | Electrical | 2100 Saint Charles Ave Unit 4E | Kitchen: Add receptacle and lower on countertop. Add 4 can less cans in kitchen and install under cabinet lights using existing circuit. Relocate Washer and dryer from kitchen to b | $4,900 |
| 26-15107-EGEN | 2026-06-02 | Electrical | 6371 Louis Xiv St | Will install a whole home 22kw generator with transfer switch | $10,038 |
| 26-14441-SERV | 2026-05-21 | Electrical | 2767 Gladiolus St | Wiring for an addition according to plans provided. Install new circuits in 3 bedrooms. Install new circuits for bathrooms. Install circuits for 3 bedrooms. Install new circuit fo | $9,000 |
| 26-11759-SERV | 2026-05-14 | Electrical | 127 Porteous St | Will provide electrical work for a remodel of kitchen and bathrooms using existing circuits. Will add a 220-volt circuit for a mini split air conditioner. | $20,000 |
| 25-36133-LOOP | 2025-11-19 | Electrical | 11739 River Rd | Will provide a 200-amp Temporary power pole for agricultural use. Please reverence Permit number 24-31265- ACCS and 25 - 25591- ACCS. This is related to the to the conversation | $1,500 |
| 25-29167-LOOP | 2025-09-24 | Electrical | 2348 Constance St | Will provide a 125amp temporary power pole for construction. | $10,500 |
| 25-25739-EVAC | 2025-08-28 | Electrical | 4708 Washington Ave | Will perform a vacancy inspection. Will bring grounding system up to code. | $1,000 |
| 25-22284-SERV | 2025-08-07 | Electrical | 7331 Lake Barrington Dr | Please see attached contract for description of work. | $9,328 |
| 25-12009-SERV | 2025-07-25 | Electrical | 1725 Saint Andrew St A | Wiring and trim out on additional small living room and small office space in garage. will install a new 100 amp service panel with 6 circuits 25-03515-RNVN | $2,700 |
| 25-21052-EVAC | 2025-07-24 | Electrical | 8214 Pritchard Pl | Will perform a vacancy inspection and repair grounding system | $1,000 |
| 25-15945-EVAC | 2025-06-24 | Electrical | 4401 Fiesta St | Performing a vacancy inspection. Will Upgrade 3 breakers to Gfci breakers and repair grounding system. 2024 | $1,250 |
| 25-13426-SERV | 2025-06-12 | Electrical | 239 Atlantic Ave | Will Install a new electrical rough in and trim out. Will install a new 200-amp electrical service with 20 new circuits | $10,500 |
| 25-13425-SERV | 2025-06-12 | Electrical | 241 Atlantic Ave | Perform electrical rough in and trim out. Will provide a 200 amp service with 20 circuits indoor with a main load center. | $10,520 |
| 25-13427-LOOP | 2025-05-05 | Electrical | 241 Atlantic Ave | Will provide a 100-amp temporary power pole for temp power for Constuction | $850 |
| 25-11391-SERV | 2025-04-29 | Electrical | 2921 Saint Thomas St | Will perform a complete rewire of residence. Will install a new 125 amp outdoor electrical service with 14 new circuits. | $4,100 |
| 24-27616-ERPR | 2024-09-20 | Electrical | 149 Audubon Blvd | Will perform electrical renovation of first floor, second floor, and third floor, including kitchen. Will bring all areas up to code. | $76,000 |
| 24-10826-ERPR | 2024-04-17 | Electrical | 15788 Chef Menteur Hwy | Will upgrade electrical service from a 125 amp to a 200 amp, by installing 200 amp meter socket and a 200 amp main disconnect. | $1,300 |
| 24-08789-SERV | 2024-04-04 | Electrical | 1325 Charbonnet St | Will Install a new complete electrical system with 25 circuits and a 200 amp overhead electrical service. | $8,500 |
| 24-08791-ERPR | 2024-04-04 | Electrical | 1337 Charbonnet St | Will provide a new complete electrical system with 25 circuits and a 200 amp service. | $8,500 |
| 24-07987-LOOP | 2024-03-21 | Electrical | 1325 Charbonnet St | Will provide a 125 amp temporary power pole for new construction. Note: Temporary power pole is included in the price for new electrical installation. | $8,500 |
| 24-07988-LOOP | 2024-03-21 | Electrical | 1337 Charbonnet St | Will provide a 125 amp temporary power for new construction. Note : Temporary power pole price is included in new construction price. | $8,500 |
| 24-06849-ERPR | 2024-03-13 | Electrical | 1901 Poydras St | EMERGENCY REPAIR. Change parallel stem conduits 3" , the feeders are 500 mcm wire. Changed 5' x 12 x 12 gutter. Terminated all connections in gutter and disconnects. Installed ne | $9,501 |
| 24-06965-ERPR | 2024-03-13 | Electrical | 1903 Poydras St | EMERGENCY REPAIR. Change parallel stem conduits 3" , the feeders are 500 mcm wire. Changed 5' x 12 x 12 gutter. Terminated all connections in gutter and disconnects. Installed ne | $9,501 |
| 24-06966-ERPR | 2024-03-13 | Electrical | 1907 Poydras St | EMERGENCY REPAIR. Change parallel stem conduits 3" , the feeders are 500 mcm wire. Changed 5' x 12 x 12 gutter. Terminated all connections in gutter and disconnects. Installed ne | $9,501 |
| 23-25204-ERPR | 2023-10-01 | Electrical | 41 Stilt St | Remodel of kitchen and new half bath using existing circuits. | $5,800 |
| 23-13581-LOOP | 2023-05-18 | Electrical | 84 Tern St | Will provide a 125 amp underground power pole | $1,500 |
| 23-08967-SERV | 2023-04-11 | Electrical | 84 Tern St | Install 200 amp service with 40 circuits fro renovation of a single family dwelling | $0 |
| 22-36557-ERPR | 2022-12-16 | Electrical | 7454 General Haig St | Remodel kitchen | $0 |
| 22-35002-LOOP | 2022-11-23 | Electrical | 434 Dauphine St | Temp service - construction loop | $0 |
| 22-28260-ERPR | 2022-09-20 | Electrical | 3534 Robert St | Re-wire by fishing conductors down walls | $0 |
| 22-16672-ERPR | 2022-06-03 | Electrical | 532 Emerald St | Remodel kitchen, office, and den using existing circuits | $0 |
| 22-16671-ERPR | 2022-06-03 | Electrical | 532 Emerald St | Wiring for a new cabana | $0 |
| 22-00483-ERPR | 2022-01-06 | Electrical | 6078 Marshal Foch St | Wiring on outdoor patio (Cabana) 21-12798-ACCS | $0 |
| 21-25131-ERPR | 2021-08-27 | Electrical | 5445 Douglass St | Fish new wiring for receptacles and lights | $0 |
| 21-24269-ERPR | 2021-08-18 | Electrical | 6153 Catina St | Use existing circuits for plugs & lights on the patio | $0 |
| 20-48924-EVAC | 2020-12-09 | Electrical | 1617 Paul Morphy St | VACANCY | $0 |
| 20-41820-ERPR | 2020-09-28 | Electrical | 1309 Marengo St | 20-28121-ACCS ADDING LIGHTS FOR NEW COVERED PATIO | $0 |
| 20-39220-ERPR | 2020-08-28 | Electrical | 3534 Robert St | PLANNED OUTAGE AND RECONNECT 20-32781-RNVN | $0 |
| 20-39173-ERPR | 2020-08-28 | Electrical | 3532 Robert St | RE-WIRE DOWNSTAIRS OF A TWO FAMILY DWELLING 20-32781-RNVN | $0 |
| 20-38990-SERV | 2020-08-27 | Electrical | 4900 Bancroft Dr | NEW 400 AMP SERVICE PANEL | $0 |
| 20-32690-ERPR | 2020-06-26 | Electrical | 4480 St Roch Ave | SERVICE INCREASE TO 200 AMPERE | $0 |
| 20-32287-ERPR | 2020-06-23 | Electrical | 4683 Gabriel Dr | REPLACE RECEPTACLES, LIGHT FIXTURES,LIGHT SWITCHES,ETC. 19-04615-RNVN | $0 |
| 20-28700-SERV | 2020-05-19 | Electrical | 1240 Behrman Ave | SERVICE INCREASE FROM 125 AMPS TO 200 AMPS | $0 |
| 19-27254-ERPR | 2019-08-28 | Electrical | 3304 Desaix Blvd | Electrical servcie change | $0 |
| 19-01338-ERPR | 2019-01-14 | Electrical | 230 Chartres St | Add 4 - 20 AMP ck's for lights + power / still entergized. | $0 |
| 18-35177-ERPR | 2018-10-23 | Electrical | 291 Bellaire Dr | Additional Upstairs. | $0 |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public New Orleans permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →