COMPANY RECORD · CHICAGO, IL
Lourjen Electric — permit history in Chicago, IL
Lourjen Electric appears on 31 Chicago permit records from 2006 through 2026, all of them electrical.
Permit categories
| Category | Permits | Share |
|---|---|---|
| Electrical | 31 | 100% |
Activity by year
| Year | Permits issued |
|---|---|
| 2006 | 1 |
| 2007 | 4 |
| 2008 | 6 |
| 2009 | 2 |
| 2010 | 2 |
| 2011 | 6 |
| 2012 | 3 |
| 2022 | 1 |
| 2023 | 3 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 | 1 |
Busiest year on record: 2008, with 6 permits. One project can account for several filings, so read this as filing activity rather than workload.
Named on the same permit
| Name in source | Linked permits | Last seen |
|---|---|---|
| Premier Exterior Home Improvement | 2 | 2008-07-22 |
| Robak Construction, Inc. | 2 | 2012-04-24 |
| A. Horn, Inc. | 1 | 2024-11-07 |
| Battis Concrete Const. | 1 | 2024-11-07 |
| Ds Construction, Inc. | 1 | 2012-01-25 |
| G3 Construction Group, Inc. | 1 | 2024-11-07 |
| Masonry Restoration Group Inc. | 1 | 2008-07-22 |
7 companies are named alongside Lourjen Electric on the same Chicago permit. A shared permit is a documented co-appearance, not proof of a current contract. Names appear as the authority published them.
Where they worked
| Address in source | Most recent permit |
|---|---|
| 1429 N LINDER AVE | 2026-04-05 |
| 6500 N NEVA AVE | 2025-10-11 |
| 10001 S PULASKI RD | 2024-11-07 |
| 2215 S MARSHALL BLVD | 2023-10-24 |
| 2312 N SPAULDING AVE | 2023-09-28 |
| 405 N WABASH AVE | 2022-02-04 |
| 2421 S WESTERN AVE | 2012-05-30 |
| 2632 N WASHTENAW AVE | 2012-04-24 |
| 3740 N ORIOLE AVE | 2011-12-06 |
| 2711 S KILDARE AVE | 2011-11-22 |
| 2258 N LEAMINGTON AVE | 2011-08-05 |
| 4890 N AUSTIN AVE | 2011-08-01 |
| 1320 N LAMON AVE | 2011-03-18 |
| 7328 W DEVON AVE | 2010-07-19 |
26 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $400 to $2,000,000, median $4,000. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.
Permits on record
31 permits; open the full list
| Permit | Issued | Category | Address in source | Scope as filed | Declared value |
|---|---|---|---|---|---|
| B200463176 | 2026-04-05 | Electrical | 1429 N LINDER AVE | LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 20 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: EXTERIOR METER LOC | $4,850 |
| B200444011 | 2025-10-11 | Electrical | 6500 N NEVA AVE | LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 8 CIRCUITS. RECEPTACLE OUTLETS: 0 . LIGHTING OUTLETS: 3. SPECIFIC LOCATION: BASEMENT AND EXTERI | $5,000 |
| 101051338 | 2024-11-07 | Electrical | 10001 S PULASKI RD | SPR 2019 CBRC: REPLACEMENT AND RELOCATION OF BASEBALL FIELD, NEW ARTIFICIAL TURF FILED, BULLPENS, DUGOUTS, 6FT TALL FENCING, BLEACHERS AND TRASH ENCLOSURE IMPORVEMENTS AT BROTHER R | $2,000,000 |
| 101033595 | 2023-10-24 | Electrical | 2215 S MARSHALL BLVD | FRAME GARAGE | $15,000 |
| B101032191 | 2023-09-29 | Electrical | 2215 S MARSHALL BLVD | INSTALL 2 EXTERIOR GFCI OUTLETS,2EXTERIOR LIGHT FIXTURES,1 LIGHT WITH MOTION SENSOR AND CAMERA,1 OUTLET INSIDE GARAGE FOR DOOR OPENER ,THREE LIGHT FIXTURES INSIDE GARAGE,SIX WALL O | $2,000 |
| B101029502 | 2023-09-28 | Electrical | 2312 N SPAULDING AVE | REPLACE EXISTING METER BANK WITH NEW 5 GANG METER ENCLOSURE UPGRADE TO 200 AMP SERVICE.PROVIDE AND INSTALL 3 NEW ELECTRICAL PANELS | $6,000 |
| B100957751 | 2022-02-04 | Electrical | 405 N WABASH AVE | RELOCATE SWITCHES AND OUTLETS IN WALL BEING REMOVED | $1,800 |
| B100443028 | 2012-05-30 | Electrical | 2421 S WESTERN AVE | UPGRADE OF ELECTRIC SERVICE FROM 100 AMPS TO 200 AMPS. REPLACE EXISTING MAIN PANEL WITH NEW 200 AMP MAIN BREAKER LOAD CENTER 40 CIRCUIT . | $3,000 |
| 100425941 | 2012-04-24 | Electrical | 2632 N WASHTENAW AVE | EXTEND KITCHEN AREA INTO PORCH AREA AS PER PLANS | $4,000 |
| 100406697 | 2012-01-25 | Electrical | 2632 N WASHTENAW AVE | INTERIOR RENOVATION OF 2 DWELLING UNIT BUILDING. UPGRADE HEATING, PLUMBING, ELECTRICAL SYSTEMS, REPLACE EXISTING REAR PORCH. DECONVERT 3 DWELLING UNITS TO 2 DWELLING UNITS (CONDIT | $150,000 |
| B100421183 | 2011-12-06 | Electrical | 3740 N ORIOLE AVE | DISCONNECT AND REMOVE ELECTRICAL WIRING AFFECTED BY WATER DAMAGE. PROVIDE AND INSTALL NEW WIRING AS NEEDED TO REPLACE DAMAGED BOXES,DEVICES,WIRES ETC.. | $4,000 |
| B100420492 | 2011-11-30 | Electrical | 2632 N WASHTENAW AVE | PROVIDE AND INSTALL NEW 200 AMP SERVICE,2 NEW TENANT PANELS AND 1 PUBLIC PANEL. PROVIDE AND INSTALL ALL NEW WIRING THROUGHOUT BUILDING WHICH INCLUDES LIGHTING, POWER,A/C,SMOKE DETE | $12,000 |
| B100419605 | 2011-11-22 | Electrical | 2711 S KILDARE AVE | PROVIDE AND INSTALL ONE LIGHT SWITCH,ONE CEILING LIGHT FIXTURE,ONE OVERHEAD DOOR OUTLET AND ONE CONVENIENCE OUTLET IN NEW ADDITION BEING CONSTRUCTED. | $550 |
| B100405804 | 2011-08-05 | Electrical | 2258 N LEAMINGTON AVE | REPLACE EXISTING 2 GANG OVERHEAD METER SOCKET WITH NEW 4 GANG TYPE. PROVIDE 2 NEW LOAD CENTERS FOR BASEMENT UNIT AND PUBLIC. RELOCATE EXISTING CIRCUITS TO CORRECT LOAD CENTERS AS N | $1,600 |
| B100405061 | 2011-08-01 | Electrical | 4890 N AUSTIN AVE | UPGRADE SERVICE FROM 60 TO 100 AMPS. PROVIDE NEW 30 CIRCUIT 100 AMP MAIN BREAKER LOAD CENTER. REWIRE ENTIRE HOUSE AND CIRCUIT TO CODE. PROVIDE NEW GFCI OUTLETS WHERE REQUIRED. | $2,200 |
| B100385381 | 2011-03-18 | Electrical | 1320 N LAMON AVE | REPLACE EXISTING DAMAGED METER FITTINGS AND 5 RENTAL UNIT LOAD CENTERS. REPLACE MISSING SERVICE ENTRANCE CABLES TO EXISTING 200 AMP MAIN BREAKER AND 60 AMP PUBLIC METER . REPAIR AN | $4,250 |
| B100354190 | 2010-07-19 | Electrical | 7328 W DEVON AVE | UPGRADE SERVICE TO 100 AMPS. PROVIDE NEW 3 GANG METER FITING FOR 1ST FL,2ND FL AND PUBLIC AS REQUIRED. PROVIDE NEW 100 AMP LOAD CENTERS FOR 1ST FL, 2ND FL AND PUBLIC TO REPLACE EXI | $2,000 |
| B100348130 | 2010-06-09 | Electrical | 5349 W WINDSOR AVE | UPGRADE EXISTING SERVICE TO 100 AMP.REPLACE EXISTING METER FITTING WITH NEW 3 GANG TYPE. REPLACE EXISTING FUSE BOXES WITH NEW 100 AMP MAIN BREAKER LOAD CNTERS. PROVIDE NEW PUBLIC M | $2,200 |
| 100306773 | 2009-08-20 | Electrical | 3348 N RIDGEWAY AVE | REPAIR OR INSTALL 15 SHEETS OF 1/4 DRYWALL ON EXISTING DRYWALL AS NEEDED IN BASEMENT, 1ST AND 2ND FLOOR. ( ELECT 100306736 ) SUBJECT TO FIELD INSPECTION | $1,500 |
| B100306736 | 2009-08-19 | Electrical | 3348 N RIDGEWAY AVE | REMOVE AND INSTALL OUTLETS AND SWITCHES FOR DRYWALL WORK IN APT. 1 AND 2 | $500 |
| 100230539 | 2008-08-20 | Electrical | 7637 W PALATINE AVE | PROPOSED SECOND FLOOR FRAME DORMER ADDITION AND INTERIOR ALTERATIONS TO EXISTING BRICK SINGLE FAMILY RESIDENCE AS PER ARCHITECT PLANS - INCLUDING ELECTRICAL, PLUMBING AND HVAC WORK | $30,000 |
| 100246741 | 2008-07-22 | Electrical | 1145 W WELLINGTON AVE | NEW DORMER ADDITION AND RENOVATIONS TO EXISTING IVA SINGLE FAMILY RESIDENCE PER PLANS - INCLUDING ELECTRICAL, PLUMBING AND HVAC WORK | $50,000 |
| B100231653 | 2008-07-04 | Electrical | 5816 S HARPER AVE | UPGRADE OF SERVICE TO 200 AMPS | $1,500 |
| B100230761 | 2008-07-04 | Electrical | 2502 W AINSLIE ST | BASEMENT REMODEL WITH 2 NEW BEDROOMS AND NEW BATHROOM. PROVIDE 2 NEW LIGHTING CIRCUITS, 2 NEW AF CIRCUITS AND 2 GENERAL RECEPTACLE CIRCUITS. ON FIRST FLOOR PROVIDE 6 NEW RECESSED D | $2,000 |
| B100157585 | 2008-07-04 | Electrical | 242 N MASON AVE | PROVIDE NEWW WIRING AND ADDITIONAL CIRCUITS TO FIRST,SECOND ,AND THIRD FLOOR UNITS AS NEEDED. | $15,000 |
| B100245855 | 2008-07-04 | Electrical | 5816 S HARPER AVE | UPGRADE OF SERVICE TO 200 AMPS | $1,500 |
| B100206287 | 2007-10-16 | Electrical | 5853 W MADISON ST | CHANGE DEFECTIVE RECEPTACLE OUTLET.REPLACE DEFECTIVE BALLAST IN 2X4 FLUORESCENT LIGHT FIXTURE.REPLACE DEFECTIVE TOGGLE SWITCH AND 6GANG SWITCH COVER AT ENTRANCE. | $400 |
| 100181918 | 2007-08-01 | Electrical | 615 E GROVELAND PARK | ERECT NEW PARTITIONS IN REAR OF SECOND FLOOR BEDROOM TO CREATE TWO BEEDROOMS TO EXISITING SFR AS PER PLANS. CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS.(NO EXTERIOR WORK OR PLU | $35,000 |
| 100158741 | 2007-02-17 | Electrical | 4850 N MEADE AVE | INTERIOR AND EXTERIOR ALTERATIONS TO EXISTING 1ST FLOOR AND NEW REAR OPEN WOOD DECK AS PER HOMEOWNER PLANS - INCLUDING ELECTRICAL, PLUMBING AND HVAC WORK | $14,000 |
| B100156402 | 2007-01-04 | Electrical | 2316 S HOMAN AVE | 100 AMP 3 METER SERVICE ..PUBLIC PANEL | |
| 100116110 | 2006-07-20 | Electrical | 6235 S MAJOR AVE | DECONVERT TO ORIGINAL [2]DU AND INTERIOR ALTERATIONS- PLUMB,HEAT,ELEC INCLUDED | $35,000 |
Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.
Source and limits
Public Chicago permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →
