COMPANY RECORD · CHICAGO, IL

Freeworld Renewables LLC — permit history in Chicago, IL

Freeworld Renewables LLC appears on 26 Chicago permit records from 2025 through 2026, all of them general construction.

Permit categories

CategoryPermitsShare
General construction26100%

Activity by year

YearPermits issued
202523
20263

Busiest year on record: 2025, with 23 permits. One project can account for several filings, so read this as filing activity rather than workload.

Named on the same permit

Name in sourceLinked permitsLast seen
Dc Will Power LLC212025-11-21
D2 Advancement LLC32026-04-14
Artisan Signs22025-04-11

3 companies are named alongside Freeworld Renewables LLC on the same Chicago permit. A shared permit is a documented co-appearance, not proof of a current contract. Names appear as the authority published them.

Where they worked

Address in sourceMost recent permit
5811 S ROCKWELL ST2026-04-14
2916 N NATOMA AVE2026-03-16
4233 W 78TH ST2026-03-05
1938 N SAWYER AVE2025-11-21
2732 W MONROE ST2025-11-11
5052 N LOCKWOOD AVE2025-11-11
1427 W BERWYN AVE2025-11-11
4944 N KENNETH AVE2025-10-14
4839 W BALMORAL AVE2025-10-08
10415 S ARTESIAN AVE2025-09-29
8315 S HOYNE AVE2025-09-18
1918 W BERWYN AVE2025-08-25
6201 W DEVON AVE2025-08-19
10409 S ARTESIAN AVE2025-08-11

21 distinct addresses on record; the 14 most recent are shown. Declared value on record runs from $23,800 to $78,827, median $36,126. Addresses appear as the authority published them. A permit is a filing at an address, not a completed job there.

Permits on record

26 permits; open the full list
PermitIssuedCategoryAddress in sourceScope as filedDeclared value
B2004531682026-04-14General construction5811 S ROCKWELL STINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.36 KW. ARRAY OUTPUT: 9.775 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOC$33,304
B2004539402026-03-16General construction2916 N NATOMA AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 3.52 KW. ARRAY OUTPUT: 4.675 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATI$25,515
B2004602252026-03-05General construction4233 W 78TH STINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 8 KW. ARRAY OUTPUT: 11 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCATION:$41,668
B2004482622025-11-21General construction1938 N SAWYER AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 5.12 KW. ARRAY OUTPUT: 6.8 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCAT$31,260
B2004364722025-11-11General construction2732 W MONROE STINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 6.72 KW. ARRAY OUTPUT: 8.925 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATION $29,882
B2004485552025-11-11General construction5052 N LOCKWOOD AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 11.5 KW. ARRAY OUTPUT: 14.025 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LO$78,827
B2004489482025-11-11General construction1427 W BERWYN AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 8.64 KW. ARRAY OUTPUT: 11.475 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATION$38,949
B2004435922025-10-14General construction4944 N KENNETH AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.36 KW. ARRAY OUTPUT: 9.775 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATI$30,348
B2004435992025-10-14General construction4944 N KENNETH AVEINSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.36 KW. ARRAY OUTPUT: 9.775 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATI$30,348
B2004440472025-10-08General construction4839 W BALMORAL AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 7.68 KW. ARRAY OUTPUT: 10.2 KW. INCLUDES 10 KWH ENERGY STORAGE SYSTEM. LOCATION: R$53,104
B2004408782025-09-29General construction10415 S ARTESIAN AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.8 KW. ARRAY OUTPUT: 6.375 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCA$28,900
B2004413742025-09-18General construction8315 S HOYNE AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.8 KW. ARRAY OUTPUT: 6.375 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCA$29,637
B2004413822025-09-18General construction8315 S HOYNE AVEINSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.8 KW. ARRAY OUTPUT: 6.375 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCA$29,637
B2004364862025-08-25General construction1918 W BERWYN AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 7.36 KW. ARRAY OUTPUT: 9.775 KW. INCLUDES 10 KWH ENERGY STORAGE SYSTEM. LOCATION: $41,370
B2004376202025-08-19General construction6201 W DEVON AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.48 KW. ARRAY OUTPUT: 5.95 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCA$29,218
B2004368152025-08-11General construction10409 S ARTESIAN AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 12.48 KW. ARRAY OUTPUT: 16.575 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERA$44,266
B2004371872025-08-11General construction10409 S ARTESIAN AVEINSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 12.48 KW. ARRAY OUTPUT: 16.575 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERA$44,266
B2004321102025-07-25General construction4925 N KENNETH AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 4.48 KW. ARRAY OUTPUT: 5.95 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATION INSTAL$25,026
B2004307772025-06-27General construction3732 W 114TH STINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 13.44 KW. ARRAY OUTPUT: 17.85 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATION INST$41,270
B2004289672025-06-25General construction2113 W BALMORAL AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.8 KW. ARRAY OUTPUT: 6 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERATION IN$25,560
B2004280872025-06-06General construction2736 S ST LOUIS AVEINSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 7.04 KW. ARRAY OUTPUT: 8.8 KW. INCLUDES 10 KWH ENERGY STORAGE SYSTEM. LOCATION: RO$43,680
B2004231172025-04-30General construction2736 S ST LOUIS AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 7.04 KW. ARRAY OUTPUT: 8.8 KW. INCLUDES 10 KWH ENERGY STORAGE SYSTEM. LOCATION: RO$43,680
B2004228752025-04-30General construction7230 S RICHMOND STINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 8.376 KW. ARRAY OUTPUT: 10.2 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCATION: R$43,188
B2004229452025-04-30General construction7230 S RICHMOND STINSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 8.376 KW. ARRAY OUTPUT: 10.2 KW. INCLUDES 5 KWH ENERGY STORAGE SYSTEM. LOCATION: R$43,188
B2004208982025-04-11General construction2063 E 72ND PLINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 5.584 KW. ARRAY OUTPUT: 0.1088 KW. LOCATION: ROOFING. ICC DISTRIBUTED GENERA$23,800
B2004181662025-03-25General construction7258 W MYRTLE AVEINSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 9.074 KW. ARRAY OUTPUT: 10.4 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: $44,740

Fields appear as the issuing authority published them, including spelling and blanks. Scope text is the applicant's description of intended work, not an inspection finding.

Source and limits

Public Chicago permit records through 2026, counted by distinct permit number. This is a historical filing record: it cannot show current backlog, pricing, crew availability, licensing or insurance, and a quiet period may only mean work was filed elsewhere. Confirm anything commercial with the company and with the issuing authority before acting. How we build these records, and what we withhold →